Safety

IMPORTANT:

Your Dacor grill is designed to be safe when installed properly. However, care must be used as these grills can produce very high temperatures which increases the potential for injury or accidents. We recommend you always follow the safety notes listed below.

NOTES:

1.

Carefully read this manual before using

 

the grill, this will reduce the risk of

 

injury due to fire or electric shock.

2.

Proper installation is extremely

 

important. Refer to the installation

 

instructions included within the

 

literature kit which shipped with your

 

grill. Your installer should show you the

 

location of the gas shut off valve and

 

the electrical connection. You should

 

also be familiar with the correct and

 

easiest way to shut off these utilities

12.Gas Smells:

If you smell gas when the unit is not in use, immediately shut off the gas at the main valve, open the canopy and call your local service agency to inspect the unit. Finding a leak is not a do-it-yourself process.

If you smell gas when the unit is in use, immediately shut off the gas at the main valve, open the canopy, and dissipate for at least five minutes. Relight the burners and verify that they are operating properly. If the burners fail to light or are not functioning properly, shut off the main gas supply valve and call your local service agency for inspection.

13.Never block the vents located on the back of the grill or the opening at the rear of the canopy. Blocking any or all of these vents during cooking, will result in damage to the unit and may cause a fire or injury.

IMPORTANT:

1.For your safety, the gas supply must be turned off at the LP-gas supply tank when your grill is not in use.

2.The LP-gas supply cylinder must be disconnected when this barbecuing appliance is not in use.

3.If the appliance is to be stored indoors, the LP tank must be disconnected and removed from the appliance.

4.LP tanks not connected for use shall not be stored in the vicinity of this or any other appliance.

5.Detach and leave the tank outdoors if storing the unit indoors. These grills are for outdoor use only.

6.Check for leaks after every tank change.

Grill Features

7

in case of an emergency. Minimum

clearances to combustible materials

should always be observed. Reference

the correct clearances in the installation

Liquid Propane Tanks

1. Dacor LP model grills are set at the

factory for LP tank installations. Use

8

 

6

6

10

 

instructions.

3. Repair and replacement of any parts

within this appliance should be

only the Dacor supplied regulator. DO

NOT ATTEMPT FIELD CONVERSIONS.

Approved field conversions from natural to

9

14

11

referred to an authorized Dacor service

technician.

LP or LP to natural will only be approved

when completed by an authorized Dacor

5

12

4.

Children should never be allowed to sit,

 

stand, or play around the grill at any

 

time. Children should never be allowed

 

to crawl inside the grill cart. Remember,

 

when in use, the grill will get hot

 

enough to cause severe burns.

5.

Avoid the potential for grease fires by

 

frequently cleaning the grease tray.

 

Always allow the unit to completely cool

 

down before removing the grease tray

 

for cleaning.

6.

Keep hands and fingers away from all

 

edges of the canopy while in the raised

 

position.

7.

Never move the grill during cooking.

8.

Always keep the canopy closed when

 

moving the grill cart.

9.

Spiders and insects can nest in the

 

burners of this grill. This can obstruct

 

the proper flow of gas into the burner

 

and cause improper operation, fire

 

hazard and potential damage to the unit.

 

Periodically inspect the burners. If any

 

of these symptoms occur, immediately

 

refer to service or the troubleshooting

 

section of this manual.

10.

Your outdoor grill is equipped with a

 

three-prong grounding plug to protect

 

animals against shock hazard. This

 

plug should be plugged directly into

 

a properly grounded three-prong

 

receptacle. Never cut or remove the

 

grounding prong from this plug.

11.

The grill canopy should be closed

 

during the pre-heating period.

servicer.

2. Dacor grills are approved for a maximum

LP tank capacity of 20 pounds (5 gallons).

The tank must be constructed and marked

in accordance with the specifications for

LP-gas tanks of the U.S. Department

of Transportation (DOT) or the National

Standard of Canada, CAN/CSA-B339, tank,

Spheres and Tubes of the Transportation

of Dangerous Goods. To minimize the

potential for fire or an explosion, the

following precautions should be observed

when using, filing, or storing an LP tank:

• Never use a dented or rusty LP tank.

If there is any question as to the

soundness of the tank, have it checked

by your LP supplier.

• Never use a tank with a damaged or

defective shut off valve.

• Do not over fill the LP tank. Never fill

the tank beyond eighty percent (80%)

of its capacity. Overfilling will cause

the pressure relief valve on the tank to

vent excess gas vapor. This vapor is

combustible and can ignite, causing a

fire.

• When transporting an LP tank, ensure it

is in an upright position and away from

any sources of high heat.

• Do not store additional LP tanks inside

the cart of the unit. Tanks must be stored

outdoors in a well-ventilated area out of

the direct sunlight and/or sources of high

heat, and out of the reach of children.

• LP tank supply systems must be

arranged for vapor withdrawal.

• LP tank used must include a collar to

protect the tank valve.

13

4

3

2

1

Built in Model EOG36 Features

EOG36 Features:

1.Rotisserie control knob

2.Grill and Smoker control knobs

3.Drip retrieval tray

4.Interior lights on/off switch

5.Stainless steel grills

6.Halogen cooking lights

7.Infrared rotisserie burner (13,000 BTU)

8.Canopy mounted temperature gauge

9.Keep warm rack

10.Rotisserie Rod and forks

11.Rotisserie Motor

12.Rotisserie Bracket

13.Removable smoker box

14.Heat control channels

8

7

6

5

11

10

9

4

3

2

1

 

 

 

 

 

Built in Model EOG52 Features

2

Image 4
Contents Use & Care Outdoor Grill Dacor Purpose of This Manual Product Registration Important InstructionsExtinguish any open flame Open LidGrill Features SafetyLiquid Propane Tanks Install Liquid Propane LP Tank EOG52 FeaturesLighting Liquid Propane Grills Lighting Natural Gas GrillsManual Lighting Canopy Mounted Temp. GaugePreheating Instructions Grill CookingCleaning Tips Always dry components completely before using the grillRotisserie Cooking Side Burners Select Models OnlyExterior Surfaces Interior SurfacesTroubleshooting Problem Possible Cause RemedyProduct Maintenance If You Need ServiceWhat is Covered What is Not CoveredBusiness Reply Mail Warranty Information