Coleman 9947A726 manual For Your Additional Safety

Page 18

Troubleshooting (cont.)

Problem: Flame behind control panel or control knob area.

Possible Causes and Solutions:

IMMEDIATELY shut off cylinder valve and allow grill to cool.

1.Check for spider webs or insect nests in venturi and clean venturi.

2.Gas is leaking from a faulty connection. Tighten connections with an adjustable wrench and replace damaged parts. Perform a leak test on all connections before cooking on grill again.

3.Venturi may be misaligned and needs to be lined up over orifice.

DANGER

If a fire occurs at the cylinder valve, DO NOT attempt to move the cylinder. IMMEDIATELY call the fire department and clear the area. You can safely spray water with a garden hose from a distance of at least 15 feet away from cylinder until firemen arrive.

For Your Additional Safety

Current L.P. gas cylinders are fitted with an Overfill Protection Device (O.P.D.). To insure that you retain this safety-device, take your cylinder to an L.P. gas service station for filling, or when exchanging your cylinder at a cylinder exchange station, request that your replacement cylinder be fitted with the O.P.D. feature.

YOUR NEW GAS GRILL IS EQUIPPED WITH A TYPE 1 CONNECTION DEVICE WHICH HAS 3 SAFETY FEATURES:

(SEE TYPE 1 CONNECTION ILLUSTRATION)

1.Proof of gas seal between the connector and the cylinder before gas flow takes place.

2.A flow-limiting device designed to limit the flow of gas in the event of a regulator or hose failure.

3.The connection has a thermal shut-off which will stop the flow of gas if the connection reaches a certain temperature.

CURRENT GAS CYLINDERS ARE ALSO EQUIPPED WITH AN OVERFILL PROTECTION DEVICE (O.P.D.) WHICH GREATLY REDUCES THE CHANCE OF ACCIDENTALLY OVERFILL- ING THE CYLINDER.

SPECIAL NOTE CONCERNING L.P. GAS CYLINDERS:

It is important to insure that your gas cylinder is properly purged before it is filled. If you purchase a new cylinder, please inform your propane gas dealer that this is a new cylin- der and needs to be properly purged before being filled.

SPECIAL NOTE CONCERNING TYPE 1 CONNECTION DEVICES:

If you notice very small flames on the burner(s), you may have accidentally activated the flow-limiting device in the Type 1 connection device. Besides a rupture in the gas hose, the flow-limiting device may activate for one of the two following rea- sons:

1.Opening the burner valves before opening the cylinder valve. SOLUTION: Shut off the burner valves and the L.P. cylinder valve and open in the proper order:

a). Open the L.P. cylinder valve first, then

b). Open burner valve and ignite the burner according to the

18instructions in this manual for your grill.

For Your Additional Safety (cont.)

IF YOU STILL HAVE A PROBLEM, THERE MAY BE AIR IN THE CYLINDER DUE TO IMPROPER PURGING.

2.The L.P. cylinder was not properly purged before it was filled. SOLUTION: See your L.P. gas supplier.

TYPE 1 CONNECTION ILLUSTRATION

Nipple with

Valve

 

Excess Flow

 

Thermal

Sensitive

Handwheel

1-5/16" Acme Connection

Regulator

Image 18
Contents Gas Barbecue Contents General Safety InformationGeneral Installation Follow these safety rules before each useClear 60cm Natural Gas Connections Electrical AttachmentsLP Fuel Connections Other Than Portable L.P. Cylinders Portable L.P. Gas Barbecue CylindersCylinder Specifications Hose and RegulatorTransporting the Cylinder Filling and Purging Type Gas Cylinders Take these instructions to the L.P. gas dealerBack-check module must be opened with an evacuation device Assembly/Set up Remove components from packageTOP Panel Bottom & Side PanelsMiddle Divider Back PanelRight Side Table Installing Ignition BOXBurner Assembly Left Side BurnerBurner Tents & Grates Hose RoutingGrease PAN & Grease Tray Warming RackUpper Door Magnets Door HandlesLower Door Magnets RotisserieConnecting Type 1 L.P. Gas Cylinders Leak TestingPropane Cylinder Setup Start-Up Check List How to Check for LeaksFixing a Fuel Leak Lighting InstructionsShutting Off the Grill Lighting Main BurnersLighting Side Burner Match-Lighting General Use and Correct Burner Flames Grilling Tips and HintsCase of Grease Fire Cleaning the VenturiCleaning and Maintenance Cooking MethodsTroubleshooting Moving and StorageFor Your Additional Safety Problem Flame behind control panel or control knob areaReplacement Parts List DescriptionWarranty For Warranty, Service and PartsColeman Co., Inc N. Hydraulic Wichita, KS 67219 U.S.A TDD
Related manuals
Manual 20 pages 48.47 Kb