Although the manufacturer has attempted to ensure that your grill will operate properly and satisfactorily, some- times problems do arise. The following troubleshooting guide lists several possible problems and their probable cause and solution.
Problem | Cause | Solution |
Burner will not light. | Gas injector not inserted in venturi | Realign/engage gas injector with the |
| tube. | venturi tube. |
| Clogged gas injector. | Remove gas injector from gas control |
|
| assembly and clean. |
| Obstruction in gas line. | For propane models, ensure gas valve |
|
| on cylinder is OFF. Remove flexible |
|
| hose and blow out any debris. |
| Spider webs in venturi tubes. | Clean venturi tubes. See Maintenance |
|
| Section. |
| Misalignment of collector box and | Position electrode properly. Clean col- |
| burner. | lector box. |
| Out of gas | Refill LP gas cylinder. If natural model, |
|
| turn on gas at source. |
| Dead battery. | Replace with AA Alkaline battery. |
Inadequate grill tempera- | Poor combustion. | Adjust air shutter. |
ture. | Misalignment of venturi tube and gas | Realign/engage gas injector with the |
| injector. | venturi tube. |
| Inadequate gas pressure. | Contact gas supplier for assistance. |
| Incorrect orifice/valve setting. | Refer to gas conversion instructions in |
|
| this manual. |
Flames blow out. | Cold grill. | Preheat grill at least 5 minutes on HI |
|
| with the grill lid closed. |
| Misalignment of burner tube and gas | Realign/engage gas injector with the |
| injector. | burner tube. |
| Poor combustion. | Adjust air shutter. |
| Extreme wind. | Turn or shield grill. |
Yellow flames. | Air shutter improperly set. | Open air shutter |
| Spider webs in venturi tubes. | Clean venturi tubes. See Maintenance |
|
| Section. |
| Seasoning salts on burner. | Clean by washing burner with mild |
|
| detergent. |
| Oil film on burner. | Allow burner to operate on HI for 10- |
|
| 15 minutes. |
Page 22 |