Aussie 6804T80SS1 manual Clean the Burners. See How to Clean Burners in Care, Maintenance

Page 34

34

Troubleshooting

Problem

 

Possible Cause

 

Solution

Regulator coupling nut is not fully connected to LP cylinder

LP-Excess flow valve tripped in regulator

Vapor lock in connections

Tighten coupling nut by hand about one-half to three quar- ters additional turn. Do not use tools.

Turn Control Knobs to “Off” position and turn LP Gas Cyl- inder handle clockwise until it stops. Wait five minutes. Relight LP gas grill. If flame continues to be low, turn off gas at LP Gas Cylinder and grill. Disconnect the regulator from the LP Gas Cylinder. Reconnect the regulator to the LP Gas Cylinder. This will reset the excess flow valve Perform a leak test. Relight grill.

 

 

Obstructions in Burners

 

Clean the Burners. See “How to Clean Burners” in Care

 

 

 

 

and Maintenance.

 

 

Wet Electrodes and Burners

 

Dry Electrode with clean cloth. Air dry or use blow dryer.

 

 

Wire loose or disconnected

 

Reconnect the wire.

 

 

Wire shorting (sparking

 

Replace Igniter Wire/Electrode assembly.

 

 

between Igniter and Electrode)

 

(Call the Customer Service Department)

 

 

 

 

 

Burners will not light Burners not assembled correctly

 

See re-assembly after cleaning in Care and Maintenance.

using a match

 

 

 

 

LP Gas Cylinder is empty

 

Take LP Gas Cylinder to licensed LP gas supplier to be refilled.

 

 

LP-Excess flow valve tripped in

 

Turn Control Knobs to “Off” position and turn LP Gas Cyl-

 

 

regulator

 

inder handle clockwise until it stops. Wait five minutes. Relight

 

 

 

 

LP gas grill. If flame continues to be low, turn off gas at LP Gas

 

 

 

 

Cylinder and grill. Disconnect the regulator from the LP Gas

 

 

 

 

Cylinder. Reconnect the regulator to the LP Gas Cylinder. This

 

 

 

 

will reset the excess flow valve Perform a leak test. Relight grill.

Regulator Coupling nut is not fully connected to LP Gas Cylinder

Obstructions in Burners

Low flame or low heat LP-gas in LP Gas Cylinder is low

Excess flow valve tripped in regulator

Tighten Regulator Coupling nut by hand about one-half to three quarters additional turn. Do not use tools.

See “How to Clean Burners” in Care and Maintenance.

Check LP Gas Cylinder. Refill if necessary.

Turn Control Knobs to “Off” position and turn LP Gas Cyl- inder handle clockwise until it stops. Wait five minutes. Relight LP gas grill. If flame continues to be low, turn off gas at LP Gas Cylinder and grill. Disconnect the regulator from the LP Gas Cylinder. Reconnect the regulator to the LP Gas Cylinder. This will reset the excess flow valve Perform a leak test. Relight grill.

Flames blow out

High or gusting winds

Turn front of grill away from wind or increase flame height.

 

Gas in LP cylinder is low

Check LP Gas Cylinder. Refill if necessary.

 

Excess flow valve tripped

See “Low flame” problem above.

Image 34
Contents DA N G E R Tools Required for Assembly Supplied with Grill Carbon Monoxide HazardPacking List DescriptionContents Preparation for AssemblyStep Caster Assembly Assembly InstructionsStep Cabinet Bottom Assembly Step Side Panel Assembly Step Front Crossbar Assembly Step Cabinet Upright AssemblyCylinder Blocking Wire Assembly Step Cylinder Guard AssemblyStep Door Handle Assembly Step Drawer Assembly Drawer PositioningStep Door Assembly Step Hood/Body To Cart AssemblyStep Side Table Assembly Step Side Burner Valve Assembly Step Side Burner Igniter Wire ConnectionStep Bottom Body Panel Assembly Step Side Burner Control Knob AssemblySide Burner Grid Assembly Foil Pan/Grease Pan AssemblyStep Warming Rack / Flavor Activator / Cooking Grid Assembly Step Battery in Igniter InstallationUsing Gas Connecting/Disconnecting the GasLP Gas Cylinder Disconnecting LP Gas Cylinder Connecting LP Gas CylinderLP Hose and Regulator Selecting a Location Before Using Your LP Gas GrillInstallation Codes Performing a Leak TestHow to Perform a Leak Test First Time USE and as required Page Lighting the Grill Using the Pulse-Spark Ignitor Off positionManual Lighting of the Grill on Manually Lighting the Grill Check The Flame Lighting the Side BurnerManually Lighting the Side Burner Manually Lighting the Side Burner Cooking On the Gas Grill Grill Cooking Direct MethodDirect Cooking on the Grids Roasting Indirect MethodIndirect Cooking Roasting Poultry Rotisserie CookingRotisserie Cooking Leg of LambWarming Rack End of Cooking SessionCare and Maintenance Cleaning the GrillHow to Clean the Burners Open up Storage Troubleshooting EmergenciesMaintenance Clean the Burners. See How to Clean Burners in CareSee How to Clean Burners in Care and Maintenance Important Notice Parts Illustration Parts List Key Description QuantityLimited Warranty Meco Corporation Limited Warranty