SURROUND LOCATION, CONNECTIONS, AND SAFETY
Surround Kit Location
This
Never install or operate your
For your safety, the
Never install or use your
CAUTION: THE INSTALLATION AND OPERATION OF THIS
A minimum clearance of
Examples of combustible materials are patio furniture, fences, or the outside of your home.
The area surrounding the
WARNING: DO NOT INSTALLOR OPERATE THIS BUILT- IN KIT WHERE GASOLINE OR OTHER FLAMMABLE MATERIALS ARE USED OR STORED. FAILURE TO COMPLY WITH THIS WARNING COULD RESULT IN EXPLOSION OR FIRE CAUSING PROPERTY DAMAGE OR PERSONAL INJURY.
CAUTION: THE GRILLAND ITS INDIVIDUAL SHUTOFF VALVE MUST BE DISCONNECTED FROM THE GAS SUPPLY PIPING SYSTEM DURING ANY SYSTEM PRESSURE TESTING AT TEST PRESSURES IN EXCESS OF 1/2 PSIG.
Checking for Gas Leaks
CAUTION: DO NOT USE AN OPEN FLAME TO CHECK FOR LEAKS. CHECKING FOR LEAKS WITH AN OPEN FLAME MAY LEAD TO A FIRE OR EXPLOSION, RESULTING IN PROPERTY DAMAGE OR PERSONAL INJURY.
Using the following steps, check for gas leaks during initial use and each time your Broilmaster® gas grill or side burner is connected to gas or is connected to a cylinder that has not been used recently
1.Using dish washing detergent and water, make a soapy solution.
2.Turn OFF the knob on both the grill and side burner’s control panel.
3.Turn ON the gas at the supply. A hissing sound indicates a leak. Turn OFF the gas and repair all leaks.
4.If no hissing occurs, apply the soapy solution to all gas connections.
5.Look for bubbles. Bubbles indicate a leak.
6.If there are bubbles, turn OFF the gas and repair all leaks.
7.Turn the gas ON and repeat the above procedure until all leaks are repaired.
Connection Requirements
CAUTION: NEVER USE LIQUID PROPANE GAS IN A GRILL DESIGNED FOR NATURAL GAS, OR NATURAL GAS IN A GRILL DESIGNED FOR LIQUID PROPANE GAS. QUESTIONS REGARDING DIFFERENT TYPES OF GASES SHOULD BE DIRECTED TO YOUR LOCAL GAS COMPANY.
Installation must conform to local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1. In Canada, installation shall be in accordance with CAN/CGA- B149.2 Propane Installation Code, or
Broilmaster® gas grills and side burners are NOT equipped with pressure regulators. Your NAT gas grill operates at a manifold pressure of seven (7”) inches water column.
Page 9 |