Weber Main Gas Line, 61626 warranty Check for GAS Leaks

Page 6

mWARNING: Make sure all control knobs are turned to the OFF position before reconnecting gas supply and operating grill. Your actions, if you fail to follow this Product Warning, may cause a fire, an explosion, or structural failure resulting in serious personal injury or death as well as damage to property.

9

CHECK FOR GAS LEAKS

mDANGER

Do not use an open flame to check for gas leaks. Be sure there are no sparks or open flames in the area while you check for leaks. Sparks or open flames will result in a fire or explosion, which can cause serious bodily injury or death and damage to property.

You will need: a soap and water solution and a rag or brush to apply it.

A)Mix soap and water.

B)Turn gas supply on at source.

C)Check for leaks by wetting fittings with soap and water solution and

watching for bubbles. If bubbles form, or if a bubble grows, there is a leak.

NOTE: When leak checking is complete, turn gas supply off at the source and rinse connections with water.

Check:

D)Hose-to-Bulkhead connection (1).

E)Main gas line-to-Bulkhead connection (2).

F)Main gas line-to-Manifold connection (3).

G)Side burner line-to-Manifold connection (4).

H)Side burner valve-to-Side burner line connection (5).

2

1

3

4

mDANGER: If there is a leak at connection (1,2,3,4 or 5), retighten the fitting with a wrench and recheck for leaks with soap and water solution. If a leak persists, turn OFF the gas. DO NOT OPERATE THE BARBEQUE. Failure to follow dangers, warnings and cautions contained in this Instruction sheet may cause a fire or an explosion resulting in serious personal injury or death as well as damage to property. Contact the Customer Service Representative in your area using the contact information on our website. Log onto www.weber.com®.

E)Valves-to-manifold connections (6).

F)Regulator-to-cylinder connections (7) (10).

G)Regulator hose-to-regulator connections (8) (11).

H)Flexible gas supply hose to gas supply connection (9) (12).

mDANGER: If there is a leak at connection (6, 7, 8, 9, 10, 11 or 12), turn off the gas. DO NOT OPERATE THE BARBEQUE. Failure to follow dangers, warnings and cautions contained in this Instruction sheet may cause a fire or an explosion resulting in serious personal injury or death as well as damage to property. Contact the Customer Service Representative in your area using the contact information on our website.

Log onto www.weber.com®.

When leak checks are complete, turn gas supply OFF at the source and rinse connections with water.

mIMPORTANT: To do a proper leak check, the control panel must be removed. After checking for leaks, replace the control panel and control knobs.

Export Gas Sources:

10

5

6

US Gas Sources:

LP

7 8

NG

9

12

LP

11

NG

Image 6
Contents Main GAS Line Disconnection of Hose from GAS Source LID Assembly and Cookbox Components Removal Control Panel RemovalMain GAS Line to Manifold Removal Main GAS Line to Bulkhead Installation Main GAS Line to Manifold InstallationMain GAS Line to Bulkhead Removal Connect by Pushing Lever/Snapping into Position Connect by Turning ClockwiseConnect by Turning Anti-Clockwise Connect by Sliding CollarCheck for GAS Leaks CheckLID Assembly and Cookbox Components Reinstallation Wash hands after handling this productWEBER-STEPHEN Products LLC

61626, Main Gas Line specifications

Weber Main Gas Line, located in the 61626 area, serves as an essential infrastructure for natural gas distribution. This gas line is engineered to deliver reliable and efficient natural gas services to residential, commercial, and industrial consumers. It plays a crucial role in powering homes, fueling businesses, and supporting various industries in the region.

One of the main features of the Weber Main Gas Line is its extensive network that connects to various supply sources. This network allows for seamless flow and distribution of gas, ensuring that customers have continuous access to this vital resource. The line is designed with a focus on safety and efficiency, employing advanced materials and technologies to minimize leaks and maximize performance.

The installation of the Weber Main Gas Line utilized state-of-the-art pipeline technology. High-strength steel is commonly used in its construction, providing durability and resistance to the pressures of natural gas transportation. Additionally, the line is equipped with sophisticated monitoring systems that detect any anomalies or pressure drops, enabling swift responses to potential issues.

Another significant characteristic of the Weber Main Gas Line is its commitment to environmental sustainability. The pipeline system incorporates advanced leak detection technologies, which are crucial for minimizing environmental impact and ensuring compliance with regulations. Through the use of innovative technologies, the Weber Main Gas Line is dedicated to reducing greenhouse gas emissions and promoting cleaner energy usage.

Customer service is also a priority for the Weber Main Gas Line operators. They offer various resources and tools online, allowing customers to easily manage their gas services and access information about energy efficiency. This focus on customer engagement enhances user experience and fosters a positive relationship between the service provider and the community.

In summary, the Weber Main Gas Line in the 61626 area is a vital component of the local energy infrastructure. With its robust design, advanced technologies, commitment to safety and sustainability, and dedication to customer service, it stands out as a reliable source of natural gas. Its efficient operation not only supports economic activities but also contributes to a more sustainable energy future.