Weber 700 owner manual To reinstall the burners, reverse steps c through g

Page 30

d)Unlatch the Spider Stopper Guards and remove. Figure 14.

Figure 14

e)Remove the manifold bracket and unscrew the two wing nuts that hold the manifold to the cooking box. Pull the manifold and valve assembly out of the burners and carefully set it down. Figure 15.

View from behind cooking box

Wing nuts

Figure 15

f)Slide the burner assembly out from under the guide screw and washer in the corners of the cooking box. Figure 16.

Guide screw

Figure 16

g)Lift and twist the burner assembly slightly, to separate the crossover tube from the burners. Figure 17. Remove the burners from the cooking box.

Crossover tube

Figure 17

h) To reinstall the burners, reverse steps c) through g).

mCAUTION: The burner openings must be positioned properly over the valve orifices. Figure 18a.

Check proper assembly before fastening manifold in place. Figure 18b.

(a)

Valve

Burner

(b)

Figure 18

30

Image 30
Contents Spirit 700 Series MDANGER MWARNINGS LP GAS Units onlyWarranty Patents and Trademarks Contents Storage For Installation in CanadaGeneral Instructions Operating areaAssembly Check package contentsStep REB Check contents of hardware packs Assemble wheel frame Assemble top frameContinue frame assembly Install tubing plugsAdd front panel Add cooking box Install manifold bracket Add fuel scale assembly Install igniterMCAUTION Do not remove adjustment wing nut from tank scale Set LP fuel scaleFill LP tank Check that all burner valves are off Connect LP tankMWARNING Do not ignite burners when leak checking Check for gas leaksInstall Flavorizer Bars and Cooking Grates Install the bottom trayInstall Lid Add tool holders, control panel and burner control knobsInstall Swing Table MWARNING The load limit for the swing table is 30 poundsComplete accessory installation Lighting To ExtinguishManual Lighting Storage and/or Nonuse Periodic CleaningCooking Storage and/or NonuseConnecting the filled LP tank Refilling the LP tankRemoval of the LP tank Male fitting Regulator Safe handling tips for LP Gas Liquid Propane LP TanksAnnual Maintenance Inspection and Cleaning of the Weber Spider Stopper GuardsMWARNING Do not ignite burners while leak checking MCAUTION Do not enlarge the burner ports when cleaning General MaintenanceMain Burner Cleaning Procedure Weber Spider Stopper GuardsTo reinstall the burners, reverse steps c through g Crossover Ignition System Operations Burner does not light, or flame is low in High position MCAUTION Do not line the bottom tray with aluminum foilPage 12-13 Parts List Final Word Thanks