Weber 56733 manual Leak Check, Check for GAS Leaks

Page 31

LEAK CHECK

CHECK FOR GAS LEAKS

For complete gas instructions see Operating Guide.

mDANGER

Do not use an open flame to check for gas leaks. Be sure there are no sparks or open flames in the area while you check for leaks. Sparks or open flames will result in a fire or explosion, which can cause serious bodily injury or death and damage to property.

Note: All factory-made connections have been thoroughly checked for gas leaks.As a safety precaution however, you should recheck all fittings for leaks before using your Weber® gas barbecue. Shipping and handling may loosen or damage a gas fitting.

mWARNING: The gas connections of your gas grill have been factory tested. We do however recommend that you leak check all gas connections before operating your gas grill.

mWARNING: Perform these leak checks even if your barbecue was dealer or store assembled.

If your grill has a side burner make sure the side burner is turned off. Turn on gas supply at source.

mWARNING: Do not ignite burners when leak checking.

You will need: A soap and water solution and a rag or brush to apply it.

A)Mix soap and water.

B)Turn on gas supply.

C)Check for leaks by wetting the fitting with the soap and water solution and watching for bubbles. If bubbles form, or if a bubble grows, there is a leak.

If there is a leak, turn off the gas and tighten the fitting. Turn the gas back on and recheck with the soap and water solution. If leak does not stop do not use the barbecue. Contact the customer service representative in your area using the contact information on our web site. Log onto www.weber.com®.

D)When leak checking is complete, turn gas supply off at the source and rinse connections with water.

Note: Since some leak test solutions, including soap and water, may be slightly corrosive, all connections should be rinsed with water after checking for leaks.

mWARNING: You should check for gas leaks every time you disconnect and reconnect a gas fitting.

Check

A)Side burner quick-disconnect connection (1).

B)Side burner extension quick-disconnect connection (2).

mWARNING: If there is a leak at connections (1 or 2), turn OFF the gas. DO NOT OPERATE THE GRILL. Contact the Customer Service Representative in your area using the contact information on our web site.

Log onto www.weber.com®.

When leak checks are complete, turn gas supply OFF at the source and rinse connections with water.

1

2

The grill illustrated may have slight differences than the model purchased.

www.weber.com® 31

Image 31
Contents Island Cabinetry Page Liquid Propane GAS Units only Únicamente Unidades DE GAS Propano Licuado AdvertenciasAppareils a GAZ Propane Uniquement Mises EN GardeGenesisIslandLPUS111810 Island Cabinetry Exploded View List Lista DEL Diagrama DE Despiece DE LOS Gabinetes DE IslasListe DE LA VUE Eclatee DES Cabinets EN Ilot Page Page Assembly Ensamlaje Assemblage Assembly Ensamlaje Assemblage Assembly Ensamlaje Assemblage Assembly Ensamlaje Assemblage Assembly Ensamlaje Assemblage Assembly Ensamlaje Assemblage Assembly Ensamlaje Assemblage Assembly Ensamlaje Assemblage To adjust door Para ajustar la puerta Pour ajuster la porte Assembly Ensamlaje Assemblage Assembly Ensamlaje Assemblage Assembly Ensamlaje Assemblage Assembly Ensamlaje Assemblage Assembly Ensamlaje Assemblage Assembly Ensamlaje Assemblage Assembly Ensamlaje Assemblage Assembly Ensamlaje Assemblage Assembly Ensamlaje Assemblage Assembly Ensamlaje Assemblage To adjust door Para ajustar la puerta Pour ajuster la porte Assembly Ensamlaje Assemblage Check for GAS Leaks Leak CheckRevisión DE Detección DE Fugas DE GAS Detección DE FugasDetection DES Fuites Detection DES FuitesPage Page WEBER-STEPHEN Products LLC