Weber 3200 Annual Maintenance, Inspection and Cleaning of the Weber Spider Stopper Guards

Page 31

Annual Maintenance

After a period of nonuse we recommend that you perform the following maintenance procedures for your safety.

mWARNING: Check hose before each use of barbecue for nicks, cracking, abrasions or cuts. If the hose is found to be damaged in any way, do not use the barbecue. Replace using only Weber authorized replacement manifold assembly. Order from Weber- Stephen Products Co., Customer Service Center or authorized dealer.

Inspect the burners for correct flame pattern. Clean if necessary, following the procedures outlined in the "General Maintenance" section of this manual.

Check all gas fittings for leaks.

mDANGER

Do not use an open flame to check for gas leaks. Be sure there are no sparks or open flames in the area while you check for leaks. This will result in a fire or explosion which can cause serious bodily injury or death, and damage to property.

mWARNING: You should check for gas leaks every time you disconnect and reconnect a gas fitting.

You will need: a soap and water solution and a rag or brush to apply it.

Make sure main burners are in the OFF position.

Make sure side burner is OFF. Remove valve control knob and screws. Remove enamel top.

To perform leak checks: Turn on gas supply.

mWARNING: Do not ignite burners while leak checking.

Check for leaks by wetting the connections with the soap and water solution and watching for bubbles. If bubbles form or if a bubble grows there is a leak.

Note - Since some leak test solutions, including soap and water, may be slightly corrosive, all connections should be rinsed with water after checking for leaks.

Check:

a)Hose to manifold connections. Figure 10 (a).

b)Regulator to tank connection. Figure 10 (b).

c)Manifold to side burner hose connection. Figure 10 (c).

mWARNING: If there is a leak at connections a, b or c, retighten the fitting with a wrench and recheck for leaks with soap and water solution.

If a leak persists after retightening the fitting, turn OFF the gas. DO NOT OPERATE THE BARBECUE. Contact

Weber-Stephen Customer Service.

d)Side burner hose to side burner connection. Figure 10 (d).

e)Valves to manifold connection. Figure 10 (e).

f)Hose to regulator connection. Figure 10 (f).

mWARNING: If there is a leak at connections d, e or f, turn OFF the gas. DO NOT OPERATE THE BARBECUE.

Contact Weber-Stephen Customer Service.

When leak checks are complete, turn gas supply OFF at the source and rinse connections with water.

(a)(b)

(c)

(d)

(f)(e)

Figure 10

Inspection and Cleaning of the Weber Spider Stopper Guards

To inspect the Spider Stopper Guards, remove the control panel and look to see if they have dust or dirt on their outside surfaces. If they do, brush off the outside surface of the Spider Stopper Guards with a soft bristle brush (an old toothbrush for example). Check that there are no gaps in the Spider Stopper Guards’ seams or in the fit around the burners or valves. (See Section "General Maintenance".)

31

Image 31
Contents Skyline LP GAS Units only MDANGER MWARNINGSWarranty Patents and Trademarks Contents Operating area For Installation in CanadaGeneral Instructions StorageCheck package contents AssemblyStep BER E W REB Check contents of hardware packs Assemble frame Assemble wheelsComplete frame assembly Continue frame assemblyInsert casters Add cooking box Install side burner locksWing nuts Cross brace Install tank panel assemblyAdd fuel scale Install igniterCheck that all burner valves are off Install manifold bracket Install side burnerMWARNING Make sure gas supply is OFF Set LP fuel scale MCAUTION Do not remove adjustment wing nut from tank scaleFill LP tank Connect LP tank MWARNING Do not ignite burners while leak checking Check for gas leaksInstall the bottom tray Install Flavorizer Bars and Cooking GratesInstall control panel and burner control knobs Install the lidSecure side burner Install the condiment basketMCAUTION Make sure both locks have snapped into place Install swing table Complete accessory installation To Extinguish LightingMWARNING Do not lean over open barbecue. Keep Manual Lighting Lighting only the side burner. Figure Lighting the side burnerStorage and/or Nonuse Periodic CleaningCooking Storage and/or NonuseRefilling the LP tank Connecting the filled LP tankRemoval of the LP tank Male fitting Regulator Collar Quick disconnect engaged DOT 4BA240 Safe handling tips for LP GasLiquid Propane LP Tanks Inspection and Cleaning of the Weber Spider Stopper Guards Annual MaintenanceMain Burner Flame Pattern General MaintenanceMCAUTION Do not enlarge the burner ports when cleaning Weber Spider Stopper GuardsView from behind cooking box Wing nuts Crossover Ignition System Operations MCAUTION Do not line the bottom tray with aluminum foil Burner does not light, or flame is low in High positionSide Burner Maintenance Side Burner TroubleshootingPage 16-17 19-20,17 Parts List Final Word Thanks