Step 17

Check for gas leaks

mDANGER

Do not use an open flame to check for gas leaks. Be sure there are no sparks or open flames in the area while you check for leaks. This will result in a fire or explosion which can cause serious bodily injury or death and damage to property.

mWARNING: You should check for gas leaks every time you disconnect and reconnect a gas fitting.

Note - All factory made connections have been thoroughly checked for gas leaks. The burners have been flame tested. As a safety precaution you should recheck all fittings for leaks before using your Weber Gas Barbecue. Shipping and handling may have loosened or damaged a gas fitting.

mWARNING: Perform these leak checks even if your barbecue was dealer or store assembled.

You will need: a soap and water solution and a rag or brush to apply it.

To perform leak checks: open tank valve by turning the tank valve handwheel counterclockwise. Figure 19.

Figure 19

Check for leaks by wetting the connections with the soap and water solution and watching for bubbles. If bubbles form or if a bubble grows there is a leak.

Note - Since some leak test solutions, including soap and water, may be slightly corrosive, all connections should be rinsed with water after checking for leaks.

mWARNING: Do not ignite burners when leak checking.

Check:

a)Hose to manifold connection. Figure 20 (a).

b)Regulator to tank connection. Figure 20 (b).

mWARNING: If there is a leak at connection (a) , retighten the fitting with a wrench and recheck for leaks with soap and water solution.

If a leak persists after retightening the fitting, turn OFF the gas. DO NOT OPERATE THE BARBECUE. Contact

Weber-Stephen Customer Service.

c)Valves to manifold connections. Figure 20 (c).

d)The hose to regulator connection. Figure 20 (d).

mWARNING: If there is a leak at connections

(b), (c) or (d), turn OFF the gas. DO NOT OPERATE

THE BARBECUE. Contact Weber-Stephen Customer Service.

When leak checks are complete, turn gas supply OFF at the source and rinse connections with water.

(a)

(b)

(c)

Figure 20

(d)

18

Image 18
Contents 1100 LP Gas Barbecue LP GAS Units only Warranty Patents and Trademarks Contents For Installation in Canada General InstructionsAssembly Check package contentsPage Check contents of hardware packs Assemble wheels Assemble top frameContinue frame assembly Complete frame assemblyInsert casters Add front panelAdd cooking box Install manifold bracket Install tank panel assembly Add fuel scale assembly Install igniterMCAUTION Do not remove adjustment wing nut from tank scale Set LP fuel scaleFill LP tank Check that all burner valves are off Connect LP tankMWARNING Do not ignite burners when leak checking Check for gas leaksInstall Flavorizer Bars and Cooking Grates Install the bottom trayInstall Lid Add tool holders, control panel and burner control knobsInstall swing table Complete accessory installation Lighting To ExtinguishManual Lighting Cooking Storage and/or NonuseDrippings and grease Periodic Cleaning Cast Iron Cooking Grates Refilling the LP tank Removal of the LP tankMale fitting Regulator Collar Quick disconnect engaged Safe handling tips for LP Gas Liquid Propane LP TanksAnnual Maintenance MWARNING Do not ignite burners while leak checkingGeneral Maintenance MCAUTION Do not enlarge the burner ports when cleaningView from behind cooking box Wing nuts Crossover Ignition System Operations Burner does not light, or flame is low in High position MCAUTION Do not line the bottom tray with aluminum foil13-14 56-60 18-19 62-63 10-14 Parts List Page Page Final Word of Thanks