Panasonic CW-XC245HU manual Before you call for service, Normal Operation, Abnormal Operation

Page 17

Before you call for service...

Troubleshooting Tips

Save time and money! Review the chart below first and you may not need to call for service.

Normal Operation

You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.

You may hear the thermostat click when the compressor cycles on and off.

Water will collect in the base pan during high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit.

The fan may run even when the compressor does not.

Abnormal Operation

Problem

Possible Causes

What To Do

 

 

 

 

 

 

The air conditioner is

• Make sure the air conditioner plug is pushed

 

 

unplugged.

completely into the outlet.

 

Air conditioner

The fuse is blown/circuit

• Check the house fuse/circuit breaker box and

 

breaker is tripped.

replace the fuse or reset the breaker.

 

does not start

 

Power failure.• When power is restored, wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload.

The current interrupter • Press the RESET button located on the power cord plug.

device is tripped.• If the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.

Airflow is restricted. • Make sure there are no curtains, blinds, or furniture blocking the front of the air conditioner.

TEMP Control is set at too • Set the TEMP Control to a lower number. high a number.

Air conditioner does not cool as it should

The air filter is dirty.

The room may have been hot.

Cold air is escaping.

Clean the filter at least every 2 weeks. See the operating instructions section.

When the air conditioner is first turned on

you need to allow time for the room to cool down.

Check for open furnace floor registers and cold air returns.

Set the air conditioner's vent to the closed position.

Before you

 

Cooling coils have iced up.

• See Air Conditioner Freezing Up below.

 

 

 

Air conditioner

Ice blocks the air flow and

• Set the mode control at High Fan or High Cool with

freezing up

stops the air conditioner

the high temperature.

 

from cooling the room.

 

 

 

 

call for service...

17

Image 17
Contents CW-XC185HU CW-XC245HU For Your Records Be sure not to do this Be sure to follow the instructions Safety PrecautionsDegrade the insulation. It may Cause an electric shock Controls About the Controls on the Air ConditionerOperation Remote controllerAir Direction How to Secure the Drain PipeVentilation How to insert batteries Care and MaintenanceAir Filter Cleaning Features FeaturesWindow Requirements InstallationHow to Install the Unit Installation Kits Contents Preparation of Chassis Suggested Tool RequirementsWindow stop moldings Cabinet InstallationSlide the unit into the cabinet.See Fig Electrical Data Use Wall Receptacle Power SupplyPlease Read Carefully Electrical SafetyAbnormal Operation Before you call for serviceNormal Operation Para SU Informacion Precauciones Importantes de Seguridad Precaucion Controles Instruccionnes de FuncionamientoENECNDIDO/APAGADO Control remotoComo controlar la direccion del aire Como Installar el Tubo de DesagüeVentilación Cómo poner las baterías Cuidado y MantenimientoLimpieza de filtro de Aire Características CaracterísticasRequisitos de ventana Instrucciones de InstalaciónElija el major lugar Contenido del juego de instalación Preparacion DEL Chasis Requisitos de las herramientas sugeridasNota Instalación del GabineteInstalacion Utilice el enchufe de la pared Datos ElectricosImportante Informacion ElectricaOperación anormal Antes de avisar al Servicio TécnicoOperación normal CW-XC145HU CW-XC185HU CW-XC245HU Panasonic Room Air Conditioner