ResMed S8 AutoScore II, S8 Series II manual Cleaning and Maintenance, Daily, Weekly, Monthly

Page 11

3Remove the Data Card by gripping the end of the Data Card and pulling it out.

4Store the Data Card in its protective folder when not in use.

5Return the card in its protective folder to your clinician using a postal envelope.

Updating Settings on your S8 device

If your clinician has provided a Data Card with new device settings:

1With the device in standby (Ramp or Settling) mode, insert the Data Card into the Data Card slot. Updating will start automatically.

The “Card Inserted Please Wait” message is displayed on the LCD while updating is in progress. Updating takes approximately five seconds.

The “Settings Success Remove Card” message is displayed on the LCD if the settings were updated successfully.

Note: This message only appears once. If you re-insert the Data Card after you have updated your settings, this message is not displayed.

2Remove the Data Card from the S8 Series II.

3Store the Data Card in its protective folder when not in use.

WARNING

! If your clinician has told you to use this Data Card to update the settings on your device and the “Settings Success” message does not appear, contact your clinician immediately.

Cleaning and Maintenance

Daily

Disconnect the air tubing and hang it in a clean, dry place until next use.

Weekly

1Remove the air tubing and wash it in warm water using mild detergent.

2Rinse thoroughly, hang, and allow to dry.

3Before next use, reassemble the mask and headgear.

4Reconnect the air tubing.

Monthly

1Clean the exterior of the S8 Series II with a damp cloth and mild liquid soap.

2Check the air filter for holes and blockage by dirt.

Cleaning and Maintenance

9

Image 11
Contents S8 Series Contents Adverse Effects IntroductionContraindications Masks Humidifiers ResScan Data Card Parts of the S8 Series II systemSetting Up Using the S8 SeriesSelecting the Mask Type How to Use the Control PanelStarting Treatment Using the Mask-fitting FeatureStandard Menu Changing the Settings on your S8 II DeviceStopping Treatment Cpap Autoset Detailed MenuCopying Data onto the Data Card Using the Data Card to Collect DataMessages on the S8 Series II LCD Monthly Cleaning and MaintenanceDaily WeeklyServicing Replacing the Air FilterHow will it feel when I am breathing with the S8 Series II? Frequently Asked QuestionsNo display TroubleshootingDisplays error message Check tube!! Key if done Power Supply Technical SpecificationsGeneral Warnings and Cautions Symbols which appear on the devicePage Limited Warranty Page Limited Warranty
Related manuals
Manual 19 pages 41.47 Kb

S8 AutoScore II, S8 Series II specifications

The ResMed S8 Series II is a prominent line of CPAP (Continuous Positive Airway Pressure) devices designed to treat obstructive sleep apnea effectively. One of the standout models within this series is the S8 AutoScore II, which has been engineered to adapt to varying patient needs with precision and comfort.

A key feature of the S8 AutoScore II is its AutoSet technology, which continuously monitors a patient's breathing patterns throughout the night. This innovation allows the device to automatically adjust the pressure delivered based on real-time data. As a result, users benefit from personalized therapy, ensuring that they receive the optimal level of air pressure needed at any given moment while they sleep.

The S8 AutoScore II also boasts an intelligent ResMed algorithm, which enhances its ability to differentiate between obstructive and central apneas. This specificity not only improves treatment efficacy but also contributes to increased patient comfort, minimizing the chances of unnecessary pressure increases that could lead to discomfort or disturbances during sleep.

Another notable aspect of the S8 AutoScore II is its user-friendly interface. The device features an intuitive LCD screen that displays essential information and settings, making it straightforward for users to navigate through various options. This simplicity is particularly beneficial for new users who may find CPAP therapy overwhelming.

In addition to its advanced technological features, the S8 Series II incorporates a compact and lightweight design, making it highly portable. Users can easily transport the device for travel or overnight stays, promoting compliance with their therapy even when away from home.

Moreover, the S8 AutoScore II comes equipped with a SmartStart function, which allows the device to automatically commence therapy once the user breathes into the mask. This feature enhances user convenience, eliminating the need for manual adjustments once the device is in place.

The S8 Series II also emphasizes quiet operation, ensuring that the device does not disturb the user or their partner during the night. Low noise levels and a comfortable fit contribute to an overall positive sleeping experience, which is crucial for the success of CPAP therapy.

Overall, the ResMed S8 Series II, particularly the S8 AutoScore II model, represents a blend of cutting-edge technology, user-centric design, and versatile functionality. These characteristics make it a reliable choice for individuals seeking effective management of obstructive sleep apnea while prioritizing comfort and convenience in their treatment journey.