Panasonic CS-MKS18NKU Installation Site Selection, Additional Materials Required for Installation

Page 101
1-5. Additional Materials Required for Installation

1-5. Additional Materials Required for Installation

1.Refrigeration (armored) tape

2.Insulated staples or clamps for connecting wire (See local codes.)

3.Putty

4.Refrigeration lubricant

5.Clamps or saddles to secure refrigerant tubing

Indoor unit

2. Installation Site Selection

2-1. Indoor Unit

WARNING

AVOID:

To prevent abnormal heat generation and the possibility of fire, do not place obstacles, enclosures and grilles in front of or surrounding the air conditioner in a way that may block air flow.

2. Installation Site Selection2-1. Indoor UnitAVOID:Fig. 3a Drain hose

Outside drainage

Fig. 1

direct sunlight.

nearby heat sources that may affect performance of the unit.

areas where leakage of flammable gas may be expected.

placing or allowing any obstructions near the air condition- er inlet or outlet.

installing in rooms that contain instant-on (rapid-start) fluorescent lamps. (These may prevent the air conditioner from receiving signals.)

places where large amounts of oil mist exist.

installing in locations where there are devices that generate high-frequency emissions.

DO:

 select an appropriate position from which every corner of

the room can be uniformly cooled. (High on a wall is best.)

 select a location that will hold the weight of the unit.

 select a location where tubing and drain hose have the

 

 

6" (15 cm)

2" (5 cm)

 

 

2" (5 cm)

min.

 

 

 

min.

 

 

min.

 

 

 

 

 

 

 

 

Front View

 

 

 

 

Fig. 2

 

 

 

INDOOR

Tubing length (L1)

 

 

 

UNIT (1)

 

INDOOR

 

 

 

 

 

 

 

 

UNIT (2)

 

 

Elevation

L2

 

 

 

difference (H1)

OUTDOOR

 

H2

 

 

UNIT

 

 

 

 

L3

 

 

H4

INDOOR

L4

INDOOR

H3

 

UNIT (4)

UNIT (3)

 

Fig. 3a

shortest run to the outside. (Fig. 1)

 allow room for operation and maintenance as well as

unrestricted air flow around the unit. (Fig. 2)

 install the unit within the maximum elevation difference

(H1, H2, H3, H4) above or below the outdoor unit and

ZLWKLQDWRWDOWXELQJOHQJWK ///////

from the outdoor unit as detailed in Table 3 and Fig. 3a.

CAUTION

For stable operation of the air conditioner, do not install wall-mounted type indoor units less than 5' (1.5 m) from floor level.

Indoor unit

Minimum height from floor level

5' (1.5 m)

Wall

Floor level

Fig. 3b

5

Image 101
Contents CS-MKS24NKU INDOOR UNIT CS-MKS7NKU CS-MKS9NKU CS-MKS12NKU CS-MKS18NKUTECHNICAL & SERVICE MANUAL DC INVERTER MULTI-SYSTEM AIR CONDITIONERSAFETY PRECAUTIONS If refrigerant gas leaks during the work, ventilate the room 2. SPECIFICATIONS Table of Contents4. REFRIGERANT FLOW DIAGRAM 8. TROUBLESHOOTING BEFORE CALLING FOR SERVICEAPPLICABLE MULTI-OUTDOOR UNITS Temperature 1. OPERATING RANGEIndoor Air Intake Temp Outdoor Air Intake TempUnit Specifications SPECIFICATIONSFeatures Dimensions & WeightDimensions & Weight FeaturesType Voltage RatingDimensions & Weight FeaturesType Voltage RatingDimensions & Weight FeaturesType Voltage RatingDimensions & Weight FeaturesType Voltage RatingDimensions & Weight FeaturesType Voltage RatingDimensions & Weight FeaturesType Voltage RatingDimensions & Weight FeaturesType Voltage RatingDimensions & Weight FeaturesType Voltage RatingDimensions & Weight 2-2-1. Indoor Unit 2-2. Major Component SpecificationsControl PCB Fan MotorIndoor Unit CS-MKS9NKU Indoor Unit CS-MKS12NKU Indoor Unit CS-MKS18NKU Indoor Unit CS-MKS24NKU Temperature F C 2-3. Other Component SpecificationsResistance k ohm CS-MKS9NKU CS-MKS12NKU 3. DIMENSIONAL DATACS-MKS18NKU CS-MKS24NKU4-1. Refrigerant Flow Diagram 4. REFRIGERANT FLOW DIAGRAM5. PERFORMANCE DATA 5-1. Air Throw Distance ChartsCS-MKS9NKU Room air temp. 80F 26.7C Cooling Cooling Cooling 6. ELECTRICAL DATA 6-1. Electric Wiring DiagramsASSY LAMP7-1. Operation Functions 7. FUNCTIONSEmergency operation SENSOR DRYTimer backup HIGH POWERNIGHT SETBACK Lamp colorsFreeze prevention 7-2. Protective Functions8-1. Precautions before Performing Inspection or Repair 8. TROUBLESHOOTING BEFORE CALLING FOR SERVICE8-2. Method of Self-Diagnostics PROCEDUREOPERATION button REMOTE CONTROL receiver INDOOR UNIT 1 OPERATION lamp 2 TIMER lamp 3 QUIET lampDIAGNOSIS CONTENTS INDICATION ON INDOOR UNITNo indicators illuminate and the indoor fan does not rotate 2 If the self-diagnostics function fails to operateCheck the power voltage Blown Check the indoor unit Is the fuse blown?T-RUN Test run compressor and fan motor turn ON 8-3. Checking the Indoor and Outdoor UnitsTimer 3 How to Identify a Serial Communication Error3-2 Condition E12 8-4-1. Indoor Fan Motor 8-4. Trouble Diagnosis of Fan MotorLocations most susceptible to noise 8-5. Noise Malfunction and Electromagnetic InterferenceTrouble CorrectionPage CS-MKS7NKU CS-MKS9NKU CS-MKS12NKU APPENDIX A Operating InstructionsCS-MKS7NKU CS-MKS9NKU CS-MKS12NKU Operating Instructions Split System Air ConditionerCU-3KS19NBU CU-4KS24NBU CU-4KS31NBU Model No Indoor UnitsCONTENTS FEATURESSAFETY PRECAUTIONS PRODUCT INFORMATIONELECTRICAL REQUIREMENTS INSTALLATION LOCATIONSAFETY INSTRUCTIONS Refrigerant gas leakage may cause fire Air Intakes INDOOR UNIT Air Outlet Remote Controller Drain Hose NAMES OF PARTSRemote Controller Refrigerant Tubes OUTDOOR UNIT Air OutletUNIT DISPLAY AND OPERATION BUTTON REMOTE CONTROLLER DISPLAY REMOTE CONTROLLER SWEEP REMOTE CONTROLLER CONTINUEDUSING THE REMOTE CONTROLLER USING THE REMOTE CONTROLLER CONTINUED 1. Operation OPERATION WITH THE REMOTE CONTROLLER3. Fan Only OPERATION WITH THE REMOTE CONTROLLER CONTINUED2. Adjusting the Fan Speed Setting 4. Night Setback ModeIn Cooling and DRY Mode and Night Setback Mode is used for saving energy5. QUIET Mode 6. HIGH POWER ModeSPECIAL REMARKS Remote Controller‘‘DRY’’ Operation Cooling Operation1. How to set the present time SETTING THE TIMERREPEAT timer SETTING THE TIMER CONTINUEDTIPS FOR ENERGY SAVING USING THE 1-HOUR OFF TIMERSetting procedure Cancellation procedureADJUSTING THE AIRFLOW DIRECTION CARE AND CLEANING OPERATION WITHOUT THE REMOTE CONTROLLERHow to remove the filter 1. Grasp both ends of the air CARE AND CLEANING CONTINUEDfilter Groove Pin Air intake grilleWashing the grille with water WIRED REMOTE CONTROLLERWhen using a footstool or the like, be careful not to let it tip over OPERATING RANGE TROUBLESHOOTING BEFORE CALLING FOR SERVICETrouble Possible CauseModel No SPECIFICATIONSIndoor Unit Outdoor UnitCS-MKS18NKU CS-MKS24NKU APPENDIX B Operating InstructionsCS-MKS24NKU CS-MKS18NKUModel No Indoor UnitsCONTENTS FEATURESSAFETY PRECAUTIONS Simple One-touch Remote ControllerELECTRICAL REQUIREMENTS INSTALLATION LOCATIONSAFETY INSTRUCTIONS Refrigerant gas leakage may cause fire Remote Controller Air Intakes INDOOR UNIT Air Outlet Remote Controller Drain HoseNAMES OF PARTS Refrigerant Tubes OUTDOOR UNIT Air OutletUNIT DISPLAY AND OPERATION BUTTON REMOTE CONTROLLER DISPLAY REMOTE CONTROLLER REMOTE CONTROLLER CONTINUED REMOTE CONTROLLER CONTINUED USING THE REMOTE CONTROLLERUSING THE REMOTE CONTROLLER CONTINUED 1. Operation OPERATION WITH THE REMOTE CONTROLLER3. Fan Only OPERATION WITH THE REMOTE CONTROLLER CONTINUED2. Adjusting the Fan Speed 4. Night Setback Mode OPERATION WITH THE REMOTE CONTROLLER CONTINUED5. QUIET Mode OPERATION WITH THE REMOTE CONTROLLER CONTINUED6. HIGH POWER Mode SPECIAL REMARKS Remote Controller‘‘DRY’’ Operation Cooling Operation1. How to set the present time SETTING THE TIMERREPEAT timer SETTING THE TIMER CONTINUEDSetting procedure USING THE 1-HOUR OFF TIMERCancellation procedure 2. Operation together with the DAILY ON/OFF REPEAT TimerADJUSTING THE AIRFLOW DIRECTION CARE AND CLEANING Groove Pin Air intake grille Air intake grille CARE AND CLEANING CONTINUED WIRED REMOTE CONTROLLEROPERATING RANGE TROUBLESHOOTING BEFORE CALLING FOR SERVICETrouble Possible CauseModel No CS-MKS7NKU CS-MKS9NKU CS-MKS12NKU CS-MKS18NKU CS-MKS24NKU APPENDIX C INSTALLATION INSTRUCTIONSContents INSTALLATION INSTRUCTIONS Split System Air ConditionerNOTE External diameter of service port R410A 5/16 For Indoor UnitWhen Transporting SPECIAL PRECAUTIONSWhen Installing… In Case of Improper Installation‡ &KHFNFDUHIXOO\IRUOHDNVEHIRUHVWDUWLQJWKHWHVWUXQ When ServicingOthers 1-1. Tools Required for Installation not supplied 1. General1-2. Accessories Supplied with Unit Table obtaining wire. Also, check1-5. Additional Materials Required for Installation 2. Installation Site Selection2-1. Indoor Unit AVOID2-2. Embedding the Tubing and Wiring trical wiring or conduits are 3. How to Install the Indoor Unit3-1. Remove the Rear Panel from the Unit 3-2. Make a Holea If Wooden Wall 3-3. Install the Rear Panel on the Wallb If Block, Brick, Concrete or Similar Type Wall Fig. 13a3-4. Removing and Installing the Grille 3-4-1. Indoor unit types Fig. 19b-1 3-4-2. Indoor unit types CS-MKS18NKU, CS-MKS24NKUFig. 16a-1 Fig. 16b-1 Fig. 17a-1 Fig. 17b-13-5. Shape the Indoor Side Tubing 3-6. Wiring Instructions General precautions on wiringFig. 26b 3-7. Wiring Instructions for Inter-unit ConnectionsFig. 26a How to connect wiring to the terminal a For Indoor Unit WARNING Loose wiring may cause the terminal to overheat or resultb For Outdoor Unit  For solid core wiring or F-cable  For stranded wiring Right-side tubing 3-8. MountingFig. 37a Fig. 37b Left-side tubing Switching drain hose and drain capDrain hose Drain captubing and wiring to the out Do not supply power to theTo unmount indoor unit 3-9. Drain HoseFig. 59c 4. How to Test Run the Air ConditionerFig. 59a Fig. 59b 5. Remote Controller Installation Position 6-1. Address Setting of the Remote Controller 6. Address Switch8. Installation Check Sheet 7. Connecting a Home Automation DevicePage DC1111-0
Related manuals
Manual 52 pages 12 Kb

CS-MKS18NKU, CS-MKS9NKU, CS-MKS24NKU specifications

The Panasonic CS-MKS7NKU, CS-MKS9NKU, and CS-MKS12NKU are part of Panasonic's reputable air conditioning lineup, designed to provide efficient and comfortable cooling and heating solutions for various spaces. These models are ideal for residential and light commercial use, showcasing a blend of innovative technology and user-friendly features.

One of the main characteristics of these units is their inverter technology, which optimizes energy consumption by adjusting the compressor speed based on the cooling or heating demand. This results in lower energy bills and a more sustainable approach to climate control, aligning with the growing demand for eco-friendly solutions. The inverter operation not only enhances energy efficiency but also contributes to quieter operation compared to traditional systems.

Another outstanding feature is the advanced air filtration system integrated into all three models. The system includes a nanoe™ X technology which utilizes nano-sized charged water particles to effectively inhibit the growth of airborne bacteria and viruses, thus improving indoor air quality. Additionally, the filters are designed for easy cleaning, providing convenience for users and reducing maintenance efforts.

The CS-MKS series also boasts a sleek and modern design that seamlessly fits into various interior decors while being compact enough for easy installation. They are engineered for whisper-quiet operation, making them suitable for bedrooms, offices, and other quiet spaces, ensuring comfort without the distraction of noise.

Moreover, these units come equipped with user-friendly remote control capabilities and Wi-Fi connectivity options, allowing users to manage their air conditioning system from anywhere using a smartphone app. This level of convenience ensures that spaces are always at the desired temperature, whether users are at home or on the go.

In terms of energy efficiency, all models are rated highly, ensuring that they not only provide comfort but also minimize environmental impact. Their eco-friendly refrigerant further supports sustainable operation, making them a top choice for environmentally conscious consumers.

In summary, the Panasonic CS-MKS7NKU, CS-MKS9NKU, and CS-MKS12NKU are highly efficient air conditioning units that combine inverter technology, advanced air purification, modern design, and smart connectivity. These features make them ideal candidates for anyone looking for reliable, eco-friendly, and user-centric climate control solutions.