Panasonic CS-A12CKP, CU-A12CKP5, CU-A7CKP5, CU-A9CKP5 Care and Maintenance, Helpful Information

Page 4
• After used over several seasons, the unit will become dirty and thus decreases the unit’s performance. Depending on the operation conditions, a dirty unit may produce odour and dust may pollute dehumidification system. Therefore, a seasonal inspection is recommended in addition to regular cleaning. (Consult an authorized dealer).
ENERGY SAVING AND OPERATION HINTS
Setting the Temperature
• Approximately 10% of electricity can be saved.
• Set the temperature higher or lower than the desired temperature.
Cooling Model
Cooling Operation : 1°C higher
Heat Pump Model
Cooling Operation : 1°C higher
Heating Operation : 2°C lower
Air Filters and Air Purifying Filters
• Clean the air filters every 2 weeks and the Air Purifying Filters every 6 months.
• Dirty filters may reduce cooling or heating efficiency.
Keep All Doors and Windows Closed
• Otherwise, cooling or heating performance will be reduced and electricity cost is wasted.
Outdoor Unit
• Do not block the air outlet vents. Otherwise, it will lower the cooling or heating performance.
Timer Mode
• To prevent wastage of electricity, use Timer when going out.
Avoid Direct Sunlight
• Keep curtains or drapes closed to avoid direct sunlight during cooling or heating operation.

CS-A7CKP CU-A7CKP5 / CS-A9CKP CU-A9CKP5 / CS-A12CKP CU-A12CKP5

CARE AND MAINTENANCE

Cleaning the Indoor Unit and Remote Control

Wipe gently with a soft, dry cloth.

Do not use water hotter than 40˚C or polishing fluid to clean the unit.

Cleaning the Air Filter

(Recommendation:- If the unit is operated in a dusty environment, clean the filters every two weeks, continuous use of this dirty filters will reduce cooling or heating efficiency)

1Remove dirt using a vacuum cleaner.

2Wash back of the air filter with water.

3If badly soiled, wash it with soap or a mild household detergent.

4Let it dry and reinstall it.

Be sure the “FRONT” mark is facing you.

Damaged air filter.

Consult the nearest authorized dealer. Part No.: CWD001047.

Do not use benzene, thinner, scouring powder or clothes soaked in caustic chemical to clean the unit.

Cleaning the Front Panel

(Must be removed before washing)

1Raise the front panel higher than the horizontal and pull to remove it.

2Gently wash with water and a sponge.

Do not press the front panel too hard when washing.

When use kitchen cleaning fluid (neutral detergent), rinse thoroughly.

Do not dry the front panel under direct sunlight.

3To fix the front panel, raise the front panel

horizontally, match the protruding portion on the indoor unit to the fulcrum and push into place.

Fulcrum

Protruding portion on indoor unit

Air Purifying Filters

Pre-season Inspection

 

Is the discharged air cold/warm?

1

Operation is normal if 15 minutes after the start of

operation, the difference between the air intake and

Raise the

outlet vents temperature is:-

front panel

Cooling Model

 

Triple Deodorizing

COOL –> 8°C or above

Filter

 

Catechin Air Purifying

Heat Pump Model

 

Filter

COOL –> 8°C or above

 

2 Remove the air filters

HEAT –> 14°C or above

Are the air intake or outlet vents of the indoor or

 

outdoor units obstructed?

Triple Deodorizing Filter

Are the remote control batteries weak?

If the remote control display appears weak, replace

• Absorb odours produced by wall paper, construction

the batteries.

material and living environment.

When the Air Conditioner is Not Used

• Reusable.

• Vacuum, place under direct sunlight for 6 hours and

for an Extended Period of Time

fit it back in place.

1 To dry the internal parts of the indoor unit, operate

(Recommended: every 6 months)

the unit for 2 - 3 hours using:-

 

Catechin Air Purifying Filter

Cooling Model

• The filter is coated with catechin to prevent growth

 

of bacteria and viruses.

FAN operation

• Reusable.

 

• Vacuum and fit it back in place

Heat Pump Model

(Recommended: every 6 months)

 

• Recommended to change these filters every 3 years.

COOL operation with 30°C

set temperature

Do not reuse damaged filters.

2 Turn off the power supply and unplug.

Consult the nearest authorized dealer to purchase a

Note: If the unit is not switched off by the remote

new filter.

control, it will start operating when you plug in

Catechin Air Purifying Filter No.: CZ-SF70P

(because the unit is equipped with Auto Restart

Triple Deodorizing Filter No.: CZ-SFD72P

Control).

• If you operate the air conditioner with dirty filters:-

3 Remove the remote control batteries.

Recommended Inspection

– Air is not purified

Cooling or heating capacity decreases

Foul odour is emitted

HELPFUL INFORMATION

Auto Operation Button

Raise the front panel and press

Automatic Operation

If the remote control fails to function or has been misplaced, press the Auto Operation button to start the Automatic operation.

The Automatic operation will be activated immediately once the Auto operation button is pressed. However, temperature cannot be adjusted in this operation.

The power indicator on the indoor unit will blink until the operation mode is selected automatically.

To cancel this operation, press once more.

Remote Control Signal Receiving Sound

To switch off the beep (Signal Receiving Sound), press the Auto Operation button for 10 seconds continuously or longer.

“Beep”, “beep” sound will be heard at the tenth seconds.

Note: “Beep” sound will be heard at the fifth seconds;

However please press continuously until you heard “beep”, “beep” sound.

Repeat the above steps if you want to switch on the Signal Receiving Sound.

(This is for Servicing purposes only)

Note: If you press this button continuously for 5 to 10 seconds, Test Run operation will be performed.

A “beep” sound will be heard at the fifth seconds indicating the Test Run starts to operate.

Auto Restart Control

If power is resumed after a power failure, the operation will restart automatically after 3 - 4 minutes.

Operation will be restarted automatically under the previous operation mode and airflow direction when power is resumed as the operation is not stopped by the remote control.

Timer Setting

When power failure occurs, the timer setting will be cancelled. Once power is resumed, reset the timer.

Thunder and Lightning

This air conditioner is equipped with a built-in surge protective device. However, in order to further protect your air conditioner from being damaged by abnormally strong lightning activity, you may switch off the main power supply and unplug from power socket.

42

Image 4
Contents Operating Instructions Safety PrecautionsName of Each Part Preparation Before Operation Remote ControlIndoor Unit Setting the Timer Convenience OperationCare and Maintenance Helpful InformationTroubleshooting Normal OperationAbnormal Operation Call the Dealer ImmediatelyInstallation Instructions Safety Precautions

CU-A12CKP5, CS-A12CKP, CS-A7CKP, CU-A9CKP5, CU-A7CKP5 specifications

The Panasonic CS-A9CKP, CU-A7CKP5, CU-A9CKP5, CS-A7CKP, and CS-A12CKP air conditioning units represent a sophisticated blend of technology and efficiency designed to cater to diverse cooling and heating needs in residential and commercial settings. These models underscore Panasonic’s commitment to innovation, energy efficiency, and user comfort.

At the heart of these air conditioning systems is the advanced inverter technology that helps achieve significant energy savings by adjusting the compressor speed according to the cooling or heating demand. This ensures a comfortable indoor temperature while reducing electricity consumption. Additionally, these models typically boast a high Energy Efficiency Ratio (EER) and Seasonal Energy Efficiency Ratio (SEER), making them environmentally friendly options.

The CS-A9CKP and CS-A12CKP are particularly noteworthy for their powerful cooling capabilities, ideal for larger rooms and spaces. They also feature a wide operating temperature range, allowing them to perform optimally even in extreme weather conditions. The CU-A7CKP5 and CU-A9CKP5 units are designed to work seamlessly with their corresponding indoor counterparts, ensuring balanced airflow and efficient temperature management.

Another exceptional feature across these units is the presence of a four-way airflow system. This technology allows for better distribution of cool or warm air throughout the room, preventing hot or cold spots and enhancing overall comfort. Additionally, many models come equipped with built-in filters that improve indoor air quality by trapping dust and allergens, ensuring a healthier living environment.

For user convenience, these models often include smart technology options, such as Wi-Fi connectivity for remote control via smartphone applications. This feature allows users to adjust settings, set timers, and monitor energy usage from anywhere, adding significant convenience.

Finally, the quiet operation of these air conditioning systems makes them suitable for residential use, especially in bedrooms or study areas. The combination of efficiency and innovation in the Panasonic CS-A9CKP, CU-A7CKP5, CU-A9CKP5, CS-A7CKP, and CS-A12CKP units not only enhances comfort but also promotes sustainability, making them a suitable investment for energy-conscious consumers. With their array of features, these models showcase Panasonic's leading role in the HVAC industry, promising reliability and performance for years to come.