Panasonic CU-E12GKE operating instructions Feature Operation, Timer Setting, Confirm, English

Page 5

FEATURE OPERATION

TO SELECT FAN SPEED

• There are 5 fan speeds, as well as automatic*.

* For automatic fan speed, the speed of the indoor fan is automatically adjusted according to the operation.

TO ADJUST AIRFLOW DIRECTION

• Keeps the room ventilated.

• There are 5 options for vertical airflow

direction.

• If automatic vertical airflow direction has been set, the louvers swing up/

down automatically.

In heat mode, the air blows horizontally for a while, then starts to blow downwards.

Do not adjust the vertical airflow direction louvers by hand.

• Horizontal airflow direction louver is

manually adjustable.

TO MONITOR AIR QUALITY

• This setting enables the patrol sensor to automatically detect the air quality.

When the air quality is unsatisfactory, e-ion operation will start automatically.

TO ENJOY CLEAN AIR

• This setting provides clean air by producing negative ions to attract dust which will then be captured at the positively charged e-ion filters.

TO ENJOY QUIET ENVIRONMENT

• This setting provides a quiet environment by reducing the airflow noise.

TIMER SETTING

TO SET THE TIMER

4)-%2

ENGLISH

• When you want the air conditioner to turn ON or OFF

automatically at a preset time.

 

Select ON

Set the

Confirm

ENGLISH

or OFF

desired

the setting.

 

timer.

time.

 

 

To cancel ON or OFF timer, press

or , then press .

• When ON Timer is set, the unit may start earlier (up

ENGLISH

 

to 30 minutes) before the actual set time in order to

 

 

 

achieve the temperature you preferred.

 

• The timers repeat daily once set.

 

 

• If there is a power failure, you can restore the

 

 

previous setting (once power is resumed) by pressing

 

 

the

button.

 

 

If the timer is cancelled, press

to restore the

 

 

previous setting.

 

ENGLISH

You can set your preferred time for ON and OFF

The timer is based on the time set in the remote

 

control.

timers.

Hints

Temperature setting of 1°C higher in cool mode or 2°C lower in heat mode than the desired temperature performs a 10% power saving.

To reduce power consumption during cool mode, close the curtains to prevent the sunlight and heat from coming in.

To disable the PATROL operation during unit start with

TO ACHIEVE TEMPERATURE QUICKLY

release.

, press and hold for 5 seconds then

• This setting enables the desired temperature to be reached quickly.

• POWERFUL operation will run for 20 minutes, after that this operation will stop automatically.

, , and operations are available in all modes and could be cancelled by pressing the respective button again.

and or and operations could not be activated at the same time.

and operations could be activated even when the air-conditioner is turned off. In this condition, once e-ion indicator is ON, the unit will operate with AUTO fan speed and air swing.

To reset, press

again for 5 seconds then

release.

 

To set either 12-hour (am/pm) or 24-hour time

indication, press and hold

for approximately 5

seconds.

 

To dim the indicator display on the air conditioner:

Press and hold for 5 seconds.

To reset, press again for 5 seconds.

To switch the temperature setting to °C or °F, press and

hold for approximately 10 seconds.

● To turn off the air conditioner, press .

5

Image 5
Contents CS-E15GKE-3 F565734CU-E15GKE-1 CU-E15GKE-3Remote Control Indoor Unit Safety PrecautionsPower Supply DefinitionOperation Condition Table of ContentsEnglish English English English Mode Operation Remote Control PreparationSelect Turn on Adjust IndicatorTimer Setting Feature OperationTime To cancel on or OFF timer, press Or , then press ConfirmSwitch off the power supply before cleaning Care & CleaningFront Panel Indoor UnitNON Serviceable Criterias TroubleshootingFor Extended NON-USE Seasonal Inspection After Extended NON-USEDefinición Precauciones DE SeguridadMando a Distancia Unidad Interior Fuente de energíaUnidad de aire acondicionado Muchas gracias por elegir unaCondiciones DE Funcionamiento ContenidoModo DE Operación Preparación DEL Mando a DistanciaSeleccionar Conectar Ajuste de ReceptorTipo DE Operación OFF Para cancelar el temporizador deAjuste DE Temporizador Activación on o el de desactivaciónApague la unidad antes de limpiarla Cuidado Y LimpiezaNo toque durante el funcionamiento Panel FrontalNo Utilice LA Unidad SI Localización DE AveríasEspañol Español English For detailed explanation, please refer to pages 4 ~ Quick GUIDE/GUIDE RAPIDE/GUÍA Rápida
Related manuals
Manual 8 pages 62.36 Kb

CU-E12GKE specifications

The Panasonic CS-E9GKEW and CU-E12GKE air conditioning units are part of Panasonic’s advanced HVAC solutions, designed to provide optimal comfort and energy efficiency for residential and commercial spaces. Notably, the models F565488, CU-E9GKE, and CS-E7GKEW complement this range, sharing cutting-edge technologies and features that set them apart in the competitive market.

One of the standout features of these units is the inverter technology. This innovation enables the compressor to adjust its speed according to the cooling demand, leading to significant energy savings while maintaining a consistent indoor temperature. By avoiding the frequent on-off cycling seen in traditional air conditioning systems, the inverter technology not only reduces power consumption but also results in quieter operation—a crucial factor for home and office environments.

The CS-E9GKEW and CS-E7GKEW variants come equipped with a powerful yet quiet fan that enhances air distribution, ensuring every corner of a room is adequately cooled or heated. The units boast a sleek and modern design that enables seamless integration into any décor while offering easy-to-use controls.

Panasonic prioritizes user comfort, evident in the addition of features like the Intelligent Sensor that detects human activity within the room. If the sensor finds no occupants, the system automatically adjusts its operation to save energy, ensuring the air conditioning is only working when necessary.

The dual functionality of cooling and heating allows these models to be used year-round, making them versatile choices for diverse climates. The heating capability is particularly beneficial in transitional weather, providing warmth when needed without switching systems.

Another notable aspect is the advanced air purification technology integrated into these systems. Panasonic’s Nanoe-G technology effectively reduces airborne pollutants, ensuring that the air quality remains high. This feature is especially important for allergy sufferers or those living in urban areas with higher levels of dust and particulates.

The CU-E12GKE and CU-E9GKE outdoor units are designed to withstand various environmental conditions, featuring robust construction and enhanced corrosion-resistance. This durability ensures longevity and performance, even in harsh weather.

In summary, the Panasonic CS-E9GKEW, CU-E12GKE, F565488, CU-E9GKE, and CS-E7GKEW units offer a blend of energy efficiency, advanced technology, and user-focused features. With their sleek designs, powerful performance, and commitment to air quality, these air conditioning solutions are ideal for those looking to enhance comfort in their living or working spaces while being mindful of energy consumption.