2DPG1000B, DPG1001B, DPG1000BBL, DPG1100B, DPG1100BBL
CAUTION:
Installation and Precautions
Install or remove gauge using wrench on hex fitting only. Do not attempt to tighten by turning housing or any other part of the gauge.
See label on back of gauge for range!
Use fittings appropriate for the pressure range of the gauge.
Do not apply vacuum to gauges not specified for vacuum operation. Permanent damage not covered by warranty will result to the sensor.
Due to the hardness of 316 stainless steel, it is recommended that a thread sealant be used to ensure
NEVER insert objects into the gauge port or blow out with compressed air. Permanent damage not covered by warranty will result to the sensor.
NOTE:
Absolute Reference Gauges
These models have engineering units shown on the rear label such as PSIA, INHGA, INH2OA, ZIN2A, BARA, MBARA, KPAA, TORR or TORRA, MMHGA, KGCMA, ATMA. The “A” indicates absolute reference. These ranges display atmospheric pressure when the gauge port is open to the atmosphere. They display zero at high vacuum.
When the gauge port is open to the atmosphere, it is normal for the reading to constantly change in response to atmospheric pressure changes. Do not adjust the calibration controls!
Operation – Ranges up to 1999
Press the round button on the front of the gauge to activate the display. The gauge will stay on for
aperiod of time determined by the
If the gauge was ordered without auto shutoff (- NS) it will stay on until the button is pressed or until the batteries are depleted. Turn gauge off when not in use to conserve battery.
Display backlighting on BBL models is on whenever the gauge is on. Backlighting may not be apparent under bright lighting conditions.
Operation – Ranges 2000 and up including 3000 psi, 5000 psi
These ranges have a
1.Make absolutely certain no pressure is applied to the gauge. The gauge por t should be exposed to normal atmospheric pressure. Note that the zeroing function may only be activated at
2.Press and hold the pushbutton.
3.The
4.Continue to press the pushbutton until o o o o is displayed and then release the button. This indicates that the gauge has been zeroed.
5.The actual pressure is displayed.
Attempting to zero the gauge with pressure greater than approximately 3% of
Absolute reference gauges do not use the zero feature since they read atmospheric pressure under normal conditions.
Normal Operation – Ranges 2000 and up including 3000 psi, 5000 psi
Following the
If excessive vacuum is applied to a
or i
Display Backlighting (BBL models only)
–Ranges 2000 and up including 3000 psi, 5000 psi
Display backlighting can be turned on by momentarily pressing the button whenever the gauge is on. The backlighting will turn on for one minute and then automatically shut off. This also restarts the auto shutoff timer. Backlighting may not be apparent under bright lighting conditions.
Shut-Down – Ranges 2000 and up including 3000 psi, 5000 psi
To shut off the gauge manually at any time, press and hold the pushbutton until the display indicates O F F and then release.
For gauges with auto shutoff, the display indicates O F F five seconds prior to auto shutoff. The pushbutton can be pressed to keep the gauge on. The auto shutoff and backlight (if equipped) timers are reset whenever the pushbutton is pressed and released.
If the gauge was ordered without auto shutoff (- NS option) it will stay on until manually shut off or until the batteries are depleted. Turn gauge off when not in use to conserve battery life.
Battery Replacement – All Models
A low battery indication will be shown in the upper
Remove the 6 Phillips head screws on the back of the unit.
Carefully remove batteries from the holders by lifting up the positive end of the battery (opposite the spring). Take care not to bend or distort the battery retention springs.
DO NOT discard the old battery into fire, any other sources of extreme heat, or in any other hazardous manner. Please consult local authorities if there is any question about proper disposal.
Always replace both batteries at the same time with high quality alkaline batteries. Observe the polarity of the batteries when replacing them. The negative (flat) end of each battery should be inserted first, and should face the spring in the battery holder.
Replace the back cover, including the rubber sealing gasket.
1000B, 1001B, 1000BBL
2.88"
31/2 digit or
41/2 digit display
1100B and 1100BBL (NEMA 4X) |
3.0" |
31/2 digit or |
41/2 digit display |
| PSIG |
Span | Zero |
OMEGA Engineering Inc./Made in USA | |
1/4"NPT | 0.75" |
3.38"
1.65"
Turn at
hex
fitting
only
PSIG |
|
Span | Zero |
OMEGA Engineering Inc. / Made in USA | |
1/4"NPT | 0.75" |
3.5" | 2.0" |
Turn at
hex
fitting
only!