?WHAT DISPLAY SYMBOLS MEAN

MONITOR COMPONENTS ?

Display

Condition/Cause

Recommended

Symbol

 

Action

 

 

 

 

 

 

 

 

 

 

 

 

Appears during

Remain still and refrain

 

 

 

 

 

 

 

 

 

 

measurement; blinks when

from talking; measurement

MEASURING

pulse is detected.

in progress.

 

 

 

 

 

 

 

 

 

 

 

 

Appears on display prior to

Press exhaust button to

 

 

 

 

 

and during measurement.

release air.

 

DEFLATE

Blinks if there is air in cuff

 

 

 

 

 

 

at power up.

 

 

 

 

 

 

Cuff needs to be inflated for

Inflate cuff 30 to 40 mmHg

 

 

 

 

 

proper measurement.

above your normal systolic

 

INFLATE

 

pressure.

 

 

 

 

 

 

 

 

 

 

 

 

An irregular heartbeat or

Take measurement again

 

 

 

 

 

 

 

 

 

 

body movement may have

and consult with your

 

 

 

occurred. Refer to page E-9

physician.

IRREGULAR

HEARTBEAT

for more information on

 

 

 

 

 

 

irregular heartbeats.

 

 

 

 

 

 

The monitor is using a fully

 

FULL BATTERY

charged battery.

 

 

 

 

 

 

The battery is low when it

Replace the battery with

LOW BATTERY

blinks.

new one, when the

 

indicator blinks.

 

 

 

 

 

 

 

 

 

 

 

Unstable blood pressure due

Try measurement again.

 

 

 

 

 

to movement during the

Remain very still during the

CUFF

SYSTOLIC PRESSURE

DISPLAY

EXHAUST VALVE

AIR TUBE

START BUTTON

DIASTOLIC PRESSURE

OR PULSE DISPLAY

 

 

 

 

 

EXHAUST

T

 

 

 

 

RING

 

 

 

 

L

MEASU

 

BEA

 

 

PRESSE HEART

 

 

 

.)

 

INFLATEAR

 

 

 

 

.(PU

 

LOW

 

 

 

IA

 

GU

 

 

 

D

 

IR

 

 

 

 

 

 

 

BATTERY

 

 

.

 

mmH

in)

 

MONITOR

 

SYS

 

PRESSURE

 

 

 

 

g(/m

 

 

 

 

 

 

BLOOD

 

 

 

 

 

mHg

-704

DIGITAL

 

 

 

 

 

 

 

 

 

 

 

m

UA

 

 

 

 

 

 

 

 

 

 

 

measurement.

measurement.

 

 

ERROR

 

The systolic and diastolic

 

 

 

 

 

 

 

 

 

 

 

 

values are within 10 mmHg

 

 

 

 

 

 

of each other.

Fasten the cuff correctly,

 

 

 

 

 

The pressure value did not

and try the measurement

 

 

 

 

 

increase during inflation.

again.

 

 

 

 

 

 

 

 

 

 

 

 

The cuff is not fastened

 

 

 

 

 

 

correctly.

 

 

 

 

 

 

 

 

 

 

 

 

 

The pulse is not detected

Try the measurement again.

 

 

 

 

 

PUL.

 

ERROR correctly.

Remain very still.

DISPLAY

E-2 ?

LifeSource Health Line (Toll-Free): 1-888-726-9966

 

INFLATOR BULB

BATTERY COMPARTMENT

BATTERY COVER AA BATTERY

In Canada (Toll-Free): 1-800-463-5414

? E-3

 

Image 3
Contents Important Information Blood Pressure MonitorTable of Contents Display Condition/Cause Recommended Symbol Action ? What Display Symbols Mean Monitor Components ?? HOW UA-704 Works Before YOU StartSelecting the Correct Cuff Taking Your Blood Pressure What is AN Irregular HEARTBEAT? About Blood Pressure What Is Blood Pressure?Keys to Successful Monitoring Specifications TroubleshootingContact Information Toll Free Canada