Panasonic CU-W12EKR operating instructions Select, Start, Desired, Operation, Set, Temperature

Page 5

AUTO, HEAT, COOL, DRY

2

AUTO

 

 

FAN

 

HEAT

 

 

SPEED

1

 

 

AIR

COOL

 

 

 

 

SWING

DRY

 

 

 

 

 

Select the

OFF

 

 

 

OFF

 

 

ON

Start the

desired

TIMER

TIMER

MODE OFF/ON

 

operation.

operation.

 

 

QUIET

 

 

FAN SPEED

 

 

POWERFUL TEMP AIR SWING

 

 

TIMER

 

 

SET

3

 

ON

 

 

 

1

 

2

3

 

OFF

 

 

CANCEL

Set the

 

SET

CLOCK

RESET

temperature.

 

 

 

 

 

 

Supersonic air purifying device (super alleru-buster) operates automatically once the unit is switched on.

POWERFUL and QUIET operations are available in all modes.

Press OFF/ON again to stop the operation.

Operation Details

AUTO - Automatic Operation

Unit selects the operation mode according to the room temperature.

Once the operation mode is selected, the unit will operate at the standard setting temperature as shown:

Room

Operation

 

Standard

 

setting

temperature

mode

 

 

 

temperature

 

 

 

 

 

23°C &

Cool

 

 

 

 

25°C

above

 

 

 

 

 

 

 

 

 

 

 

Below

Dry

 

 

 

 

22°C

23°C

 

 

 

 

 

 

 

 

 

 

 

Below

Heat

 

 

 

 

21°C

20°C

 

 

 

 

 

 

 

 

 

 

 

• Press

or

 

to change the

temperature setting to “HI” or “LO”

as shown:

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation mode

 

 

HI

 

LO

 

 

 

 

 

 

Cool

 

 

27°C

 

23°C

 

 

 

 

 

 

Dry

 

 

24°C

 

20°C

 

 

 

 

 

 

Heat

 

 

23°C

 

19°C

 

 

 

 

 

 

 

 

HEAT - Heating Operation

In heating mode, it takes a while for the unit to warm up. The power indicator blinks during this operation.

The range of temperature can be selected from 16°C ~ 30°C.

COOL - Cooling Operation

Enjoy cool air at your desired temperature.

The range of temperature can be selected from 16°C ~ 30°C.

DRY - Soft Dry Operation

Keep your environment dehumidified by running cooling operation at a low fan speed.

The range of temperature can be selected from 16°C ~ 30°C.

Hint

A temperature setting 1°C higher in cooling operation or 2°C lower in heating operation than the desired temperature equates to a 10% power saving.

ENGLISH

Troubleshooting

● Mist emerges from indoor unit.

► Condensation effect due to cooling process.

● Heating/Cooling operation does not work.

► Ensure temperature is set correctly.

 

► Make sure windows and doors are closed.

 

► Make sure filters are cleaned and replaced.

 

► Make sure inlet and outlet vents are cleared.

 

 

● Water flowing sound during operations.

► Cause by refrigerant flow inside the unit.

 

 

The power indicator blinks during the operation and ► The unit is in defrost mode, and the melted frost is drained from the

the indoor fan is stopped.

outdoor unit.

5

Image 5
Contents Operating Instructions Air Conditioner Definition Safety PrecautionsThank you for purchasing Panasonic Air Conditioner Operation Condition Regulatory InformationAbout IndicatorProduct Overview Select TemperatureStart DesiredSelect fan speed Adjust the airflow direction louverFAN SPEED, AIR Swing Enables quiet operation Enables powerful operation POWERFUL, QuietOFF timer TimerSelect on or HintsCare & Cleaning Seasonal Inspection After Extended NON-USE NON Serviceable Criterias F565374 OPTH0604-00

CU-W12EKR specifications

The Panasonic CU-W12EKR is a standout model in the world of air conditioning, designed to enhance indoor comfort while promoting energy efficiency. This model combines advanced technology with user-friendly features, making it a popular choice for both residential and commercial applications.

One of the primary features of the CU-W12EKR is its cooling capacity, which effectively manages indoor temperatures in spaces of various sizes. With a cooling capacity of 12,000 BTU, it is capable of providing a balanced cooling environment even on the hottest days. The unit operates quietly, ensuring that occupants can enjoy a peaceful atmosphere without disruptive noise.

Energy efficiency is a hallmark of the CU-W12EKR. It is designed with a high Energy Efficiency Ratio (EER) that minimizes power consumption, making it an eco-friendly choice for the environmentally conscious consumer. This is particularly important given today’s rising energy costs and the growing emphasis on sustainability.

The CU-W12EKR also features advanced inverter technology. This innovation allows the unit to adjust its cooling output to match the room's requirements, resulting in significant energy savings. The inverter system enhances the air conditioner's performance by preventing temperature fluctuations and ensuring a consistent environment.

Another notable characteristic is its user-friendly interface. The Panasonic CU-W12EKR is equipped with a remote control, allowing users to adjust settings from a distance. This convenience is complemented by programmable timers and sleep modes that enable automated operation, further optimizing energy usage and convenience.

The unit is built with robust materials designed for durability, ensuring long-term reliable performance. Its sleek design complements modern interiors, making it an aesthetically pleasing choice for various settings.

Additionally, maintenance is simplified with washable filters, promoting cleaner air and reducing the need for frequent replacements. The easy access to components ensures that servicing the unit is a straightforward process, contributing to its overall longevity and effectiveness.

In conclusion, the Panasonic CU-W12EKR is a powerful and efficient air conditioning system, offering advanced technologies, energy-saving features, and user-friendly controls. Whether for home or office use, it provides a comfortable and quiet environment, making it an ideal choice for those seeking both quality and efficiency in their heating and cooling solutions.