I.V. ROD TELESCOPING KIT
9000XT RECLINER - KIT NO. 1074656 2000, 4000 AND 9000 RIDELITE RECLINER - KIT NO. 1029598
Installation, Assembly and Operating Instructions
NOTE: Check ALL parts for shipping damage. In case of | 1. Remove the rear wheel from the wheelchair. Refer to | ||
shipping damage, DO NOT use. Contact Carrier/Dealer | REMOVING/INSTALLING THE REAR WHEELS | ||
for further instruction. | in this instruction sheet. |
| |
| SAFETY SUMMARY | 2. Remove the arm from the wheelchair. Refer to RE- | |
The following recommendations are made for safe instal- | MOVING/INSTALLING THE ARMRESTS in this in- | ||
struction sheet. |
| ||
lation and adjustment of the I.V. Rod Telescoping Kit: |
| ||
|
| ||
|
| 3. Remove the locknut and hex screw that secure the | |
| GENERAL WARNINGS | ||
| arm socket to the wheelchair frame. |
| |
| DO NOT install or use this equipment with- |
| |
| 4. Remove the locknut that secures the back tube to the | ||
| out first reading and understanding this | ||
| instruction sheet. If you are unable to un- | clevis bracket. |
|
| derstand the Warnings, Cautions or Instruc- | 5. Position the I.V. holder on the existing pivot bolt as | |
| tions, contact a healthcare professional, | shown in FIGURE 1. |
|
| dealer or technical personnel before at- |
|
|
| tempting to install this equipment - other- |
| Hex |
| wise, injury or damage may occur. | Arm Socket | |
| DO NOT pull/push the wheelchair by the | (OUTSIDE of | Screw |
|
| ||
| I.V. rod assembly. Injury to the assistant/ | Wheelchair |
|
| occupant and/or damage to the I.V. rod | Frame) |
|
| assembly may occur. |
|
|
| DO NOT place any other objects on the | Locknut | STEP 3 |
| I.V. rod assembly other than those deter- | Outside of | |
| mined by a healthcare professional. |
| |
|
| Wheelchair |
|
| INSTALLATION WARNINGS |
| |
| Frame |
| |
|
|
|
|
After ANY adjustments, repair or service |
| |
and BEFORE use, make sure all attaching | Locknut | |
hardware is securely tightened - other- | (STEP 8,9,11) | |
wise injury or damage may result. | Side Frame | |
Use EXTREME caution when the I.V. rod | ||
| ||
holder for MODELS 2000, 4000 and 9000 | I.V. Holder | |
Ridelite is installed. When installed, the rear | (STEP 5) | |
arm release lever is removed and will NOT |
| |
lock the arm in place. | Mounting | |
| ||
NOTE: If installing the telescoping I.V. rod holder onto | Screw | |
a 2000, 4000 or 9000 RIDELITE, refer to INSTALL- | (STEP 7) | |
ING THE TELESCOPING I.V. ROD HOLDER - 2000, |
| |
4000 or 9000 RIDELITE in this instruction sheet. |
|
Back Tube
(STEP 4)
Clevis
Bracket
(STEP 4)
Pivot Bolt
(STEP 5)
Flat Portion
(STEP 5)
INSTALLING THE TELESCOPING I.V. ROD HOLDER - 9000XT ONLY (FIGURE 1)
NOTE: Refer to INSTALLATION WARNINGS in the
SAFETY SUMMARY in this instruction sheet.
Front | Locknut | |
(STEPS 4,6,11 ) | ||
Cylinder | ||
|
FIGURE 1 - INSTALLING THE
TELESCOPING I.V. ROD HOLDER
1