Invacare XL, 5, 10 manual Routine Maintenance

Page 27

SECTION 6 —MAINTENANCE

SECTION 6 — MAINTENANCE

NOTE: The Invacare concentrators are specifically designed to minimize routine preventive maintenance. In places with high dust or soot levels, maintenance may need to be performed more often. Only authorized or factory-trained personnel should perform preventive maintenance on the concentrator. Power should be disconnected before beginning preventive maintenance on the Invacare concentrator.

NOTE: At a minimum, preventive maintenance MUST be performed according to the maintenance record guidelines. Refer to Preventive Maintenance Record on page 29.

Routine Maintenance

NOTE: The following routine maintenance should be performed more frequently. See recommended intervals in each section and preventive maintenance record.

Cleaning the Cabinet Filter

NOTE: For this procedure, refer to FIGURE 6.1.

NOTE: There are two cabinet filters one located on each side of the cabinet.

1.Remove each filter and clean at least once a week depending on environmental conditions.

NOTE: Environmental conditions that may require more frequent

cleaning of the filters include but are not limited to: high dust, smoking, air pollutants, etc.

2.Clean the cabinet filters with a vacuum cleaner or wash in warm soapy water and rinse thoroughly.

3.Dry the filters thoroughly before reinstallation.

Part No 1145728

27

Platinum™Series

Image 27
Contents PlatinumSeries XL, 5 Accessories Table of Contents Français Entretien Special Notes General Guidelines General Guidelines Radio Frequency Interference MaintenanceImmediately Polarized Plug Instruction Accessories not Shown FeaturesStorage HandlingUnpacking InspectionSpecifications Label Symbol O2 Purity Indicator Lights SensO2 Model Low Flow Alarm Specifications Operating Instructions IntroductionSelect a Location Recommended Guidelines for Optimum Performance Plug in Power CordHumidifier Compartment Connect Humidifier If So PrescribedOperating Instructions Humidifier Bottle Adapter Power Switch Power SwitchFlowrate FlowrateInitial Startup of the Concentrator Explanation of Oxygen Purity Indicator LightsLX models indicator Light Explanation Indicators If Your Unit Does Not Feature the O2 SensorRoutine Maintenance MaintenanceCabinet Preventive Maintenance Record Solution Troubleshooting GuideTroubleshooting Guide Symptom LOW Flow Alarm Limited Warranty Limited Warranty Platinumsérie XL, 5 Accessoires Remarques Spéciales Présentation Globale Mise EN Garde Interférence radioélectrique EntretienMise EN Garde Instructions sur la fiche polarisée Écoulé CaractéristiquesDéballage ManipulationEntreposage Spécifications Symbole Pureté O2 Voyants Avec arrêt du compresseur. Alarme basse Spécifications Choisir un endroit Consignes ’UTILISATIONBrancher le cordon électrique Recommandations pour garantir des performances optimalesRemarque Pour cette procédure, se reporter à la .1 Figure Raccorder l’humidificateur si cela a été recommandéConsignes D’UTILISATION Filtre Fixation du tube à oxygène InterrupteurDébit DébitExplication des voyants de pureté de l’oxygène Mise en marche initiale du concentrateurExplication des témoins sur le modèle LX Entretien Maintenance de routineCoffret NE PAS trop remplir le flacon d’humidificateur Relevé DE L’ENTRETIEN Préventif PAS Guide DE DépannageGuide DE Dépannage Symptôme Alarme DE BAS Garantie Limitée Garantie Limitée USA

XL, 5, 10 specifications

The Invacare 10,5,XL is a state-of-the-art power wheelchair designed to offer users exceptional mobility, comfort, and accessibility. This model stands out for its innovative engineering and user-centric features, making it ideal for individuals seeking independence in their daily lives.

One of the key highlights of the Invacare 10,5,XL is its advanced seating system. The wheelchair is equipped with a highly adjustable seat that allows for optimal positioning. Users can customize the height, depth, and angle of the seat to suit their unique needs, ensuring maximum comfort during extended use. The breathable fabric not only provides comfort but also enhances airflow, reducing the risk of skin irritation.

The wheelchair's design incorporates a robust yet lightweight frame, allowing for enhanced maneuverability both indoors and outdoors. Its compact dimensions make it easy to navigate through narrow spaces, while the powerful motors provide a smooth ride on various terrains. Whether tackling gravel paths or carpeted floors, the Invacare 10,5,XL ensures a stable and enjoyable experience.

Another impressive feature is the intuitive control system. Equipped with a user-friendly joystick, the Invacare 10,5,XL allows for precise navigation with minimal effort. The control interface is designed for ease of use, making it accessible even for those who may not have extensive experience with power wheelchairs.

Safety is a top priority in the design of the Invacare 10,5,XL. The wheelchair comes with anti-tip wheels to enhance stability on inclines and declines. Additionally, the durable tires provide excellent traction, ensuring that users can travel confidently across different surfaces without fear of slipping.

Battery life is another critical characteristic of the Invacare 10,5,XL. The wheelchair boasts high-capacity batteries, allowing for extended travel distances on a single charge. This feature is particularly beneficial for users who require mobility solutions for longer outings, minimizing the need for frequent recharging.

The Invacare 10,5,XL also includes customizable options, enabling users to personalize their wheelchair to reflect their lifestyle and preferences. From various armrest styles to alternate joystick positions, the wheelchair can be tailored to meet individual needs.

In summary, the Invacare 10,5,XL combines innovative technology with practical features, making it a top choice for those seeking a reliable and comfortable power wheelchair. Its focus on user comfort, safety, and personalization ensures that it meets the diverse needs of its users, enhancing their quality of life and independence.