Emerson Process Management 430 DO Essential Instructions, Hazardous Area Installation

Page 2

ESSENTIAL INSTRUCTIONS

READ THIS PAGE BEFORE PROCEEDING!

Rosemount Analytical designs, manufactures, and tests its products to meet many national and international standards. Because these instru- ments are sophisticated technical products, you must properly install, use, and maintain them to ensure they continue to operate within their normal specifications. The following instructions must be adhered to and integrated into your safety program when installing, using, and maintaining Rosemount Analytical products. Failure to follow the proper instructions may cause any one of the following situations to occur: Loss of life; personal injury; proper- ty damage; damage to this instrument; and warranty invalidation.

Read all instructions prior to installing, operating, and servicing the prod- uct. If this Instruction Manual is not the correct manual, telephone 1-800- 654-7768 and the requested manual will be provided. Save this Instruction Manual for future reference.

If you do not understand any of the instructions, contact your Rosemount representative for clarification.

Follow all warnings, cautions, and instructions marked on and supplied with the product.

Inform and educate your personnel in the proper installation, operation, and maintenance of the product.

Install your equipment as specified in the Installation Instructions of the appropriate Instruction Manual and per applicable local and national codes. Connect all products to the proper electrical and pressure sources.

To ensure proper performance, use qualified personnel to install, operate, update, program, and maintain the product.

When replacement parts are required, ensure that qualified people use replacement parts specified by Rosemount. Unauthorized parts and pro- cedures can affect the product’s performance and place the safe opera- tion of your process at risk. Look alike substitutions may result in fire, elec- trical hazards, or improper operation.

Ensure that all equipment doors are closed and protective covers are in place, except when maintenance is being performed by qualified persons, to prevent electrical shock and personal injury.

DANGER

HAZARDOUS AREA INSTALLATION

Installations near flammable liquids or in hazardous area locations must be carefully evaluated by qual- ified on site safety personnel. This sensor is not Intrinsically Safe or Explosion Proof.

To secure and maintain an intrinsically safe instal- lation, the certified safety barrier, transmitter, and sensor combination must be used. The installa- tion system must comply with the governing approval agency (FM, CSA or BASEEFA/CEN- ELEC) hazardous area classification require- ments. Consult your analyzer/transmitter instruc- tion manual for details.

Proper installation, operation and servicing of this sensor in a Hazardous Area Installation is entirely the responsibility of the user.

CAUTION

SENSOR/PROCESS

APPLICATION COMPATIBILITY

The wetted sensor materials may not be compatible with process composition and operating conditions. Application compatibility is entirely the responsibili- ty of the user.

About This Document

This manual contains instructions for installation and operation of the Model 430 Dissolved Oxygen Sensor. The following list provides notes concerning all revisions of this document.

Rev. Level

Date

Notes

A

5/96

This is the initial release of the product manual. The manual has been refor-

 

 

matted to reflect the Emerson documentation style and updated to reflect any

 

 

changes in the product offering.

Emerson Process Management

Liquid Division

2400 Barranca Parkway

Irvine, CA 92606 USA

Tel: (949) 757-8500

Fax: (949) 474-7250

http://www.raihome.com

© Rosemount Analytical Inc. 2003

Image 2
Contents Dissolved Oxygen Sensor Hazardous Area Installation Essential InstructionsTable of Contents Model Dissolved OxygenTable of Contents List of Figures List of TablesSection General Description and Specifications Features and ApplicationsTemperature Compensation Specifications Process ConnectionWetted Materials Housing PVC Membrane Teflon 4004301940043018 Optional Mounting BracketModel Section Installation Electrode Connections Sensor Lead Model 1181DOCodes and 01 and 02 Flow Through Installation 40043001Code 03 Sensor Dimensions 40043002Page Section Maintenance Do not Remove ITSection Troubleshooting Temperature Resistance ChartSection Parts Lists 4004505240043016 Part Number Description Qty40043015 40043017 NON Warranty REPAIR. Contact Factory For Authorization Section Return of MaterialEUROPE, Middle EAST, and Africa Americas HeadquartersASIA-PACIFIC Additional Sales OfficesReturn of Materials Request Sensor or Circuit Board onlyPage Warranty Specifications subject to change without notice

430 DO specifications

Emerson Process Management has long been a pioneer in the field of automation and instrumentation, and one of its standout products is the 430 DO, a digital output module widely used in various industrial applications. The 430 DO is engineered to facilitate increased efficiency, reliability, and flexibility in process management systems.

One of the main features of the 430 DO is its ability to support a range of output configurations. It typically offers multiple channels, allowing operators to control various field devices simultaneously. This high-density output capability makes it ideal for applications where space and resources are constrained.

The module utilizes advanced digital signal processing technology, which enhances its performance and responsiveness. This technology ensures that the 430 DO can handle robust signal processing, leading to improved speed and accuracy in control processes. Moreover, the module complies with the industry standards for electromagnetic compatibility (EMC), ensuring minimal interference and enhanced operational integrity in diverse environments.

In terms of connectivity, the 430 DO is designed to integrate seamlessly within Emerson's DeltaV™ control system, enabling quick deployment and straightforward configuration. The use of an intuitive interface simplifies setup and allows operators to quickly adapt to changing process requirements. Additionally, the module supports extensive communication protocols, which facilitates interoperability with various devices and systems, enhancing overall operational versatility.

Another notable characteristic of the 430 DO is its built-in diagnostic capabilities. Real-time monitoring offers insights into the status and health of the outputs, allowing for proactive maintenance actions to be taken before potential failures occur. This feature not only enhances operational reliability but also contributes to reduced downtime and maintenance costs.

Safety is paramount in any industrial environment, and the 430 DO module incorporates safety features that comply with international safety standards. These features enable fail-safe operations, ensuring that process integrity is maintained even in the event of an unexpected shutdown or fault.

In summary, Emerson Process Management's 430 DO digital output module stands out for its versatile output configurations, advanced signal processing technologies, seamless integration with control systems, built-in diagnostics, and emphasis on safety. Its design reflects Emerson's commitment to providing tools that enhance performance and streamline operations in the ever-evolving landscape of industrial automation. With the 430 DO, organizations can expect improved efficiency and reliability in their process management systems.