GE JT952SK dimensions Dimensions and Installation Information, Must Support 275 LBS

Page 1

JT952SK

GE Profile30" Built-In Double Oven

Dimensions and Installation Information

KW Rating

 

 

 

 

 

 

 

240V

 

7.2

 

 

 

 

 

 

 

208V

 

5.4

 

 

 

 

 

 

Breaker Size

 

 

 

 

 

 

240V

 

40 Amps

 

 

 

 

 

 

 

208V

 

30 Amps

 

 

 

 

 

 

 

 

 

 

 

Cabinet

 

 

30"

 

 

A - Overlap of Oven Over Side Edges of Cutout

11/16"-3/4"

 

 

B - Overlap of Oven at Bottom of Cutout

1"

 

 

 

 

Oven

 

 

 

 

 

C - Overall Depth

23-1/2"

 

 

D - Overall Height

52-7/8"

 

 

E - Overall Width

29-3/4"

 

 

 

 

 

Note: Cabinets installed adjacent to wall ovens must have an adhesion spec of at least a 194°F temperature rating. Electric wall ovens are not approved for installation with a plug and receptacle. They must be hard wired in accordance with installation instructions.

Installation Information: Before installing, consult installation instructions packed with product for current dimensional data.

For answers to your Monogram,® GE Profileor GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.

C

 

Cutout width

 

 

L

2 x 4 or

28-1/2'' MIN.

5

Cutout

 

equivalent

28-5/8'' MAX.

 

 

 

depth

 

runners

 

 

 

 

 

23-1/2"

 

 

 

 

 

 

 

 

MIN

 

 

 

 

Junction

 

E

A

 

box

 

Suitable

 

location

 

bracing

B

 

 

 

to support

 

 

 

 

 

 

18"

runners

Conduit

 

 

 

 

 

(48-1/2"

 

 

over centerline

 

 

 

long)

 

 

of cabinet

 

 

47" to

 

 

 

(Must Support 275 LBS.)

 

 

 

bottom of

 

 

 

Cutout height

junction

 

 

 

box

 

D

 

51-13/16" MIN.

 

 

51-15/16" MAX.

 

A

21

 

 

21" minimum

B

Minimum cutout

Door Opening

 

Allowance

 

location 12"

C

 

from the floor.

Cabinet

 

 

width 30"

 

 

MOST 30'' WALL CABINETS CAN BE USED WITH THIS UNIT.

THE OPENING BETWEEN THE INSIDE WALLS MUST BE AT LEAST 28-1/2'' WIDE.

Dimension and installation information are shown in inches.

Listed by

Underwriters

Laboratories

R

Specification Created 1/05

220131

Image 1
Contents Must Support 275 LBS Dimensions and Installation InformationCabinet Width Features and Benefits