10 TEST INSTALLED FITTING

 

With HANDLES (1) in OFF position, turn on WATER

 

SUPPLIES (2) and check all connections for leaks.

 

Remove AERATOR (3).

4

Operate both HANDLES (1) to flush water lines thoroughly.

1

Replace AERATOR (3).

1

CHECK DRAIN CONNECTIONS

Operate POP-UP KNOB (4) and fill lavatory with water. Check that DRAIN STOPPER (5) makes a good seal and retains water in SINK. If DRAIN STOPPER (5) does not seal properly, please refer to Troubleshooting section in these instructions.

Release POP-UP KNOB (4) down and check all drain

3

5

connections and "P" trap for leaks. Tighten

if necessary.

 

WASTE

OUTLET

2

2

“P” TRAP

 

11 SERVICE

To change direction of handle:

Turn valve to OFF position

 

Remove SET SCREW (6) with 5/64" Hex Wrench.

 

Pull HANDLE (1) “UP” firmly to release from ADAPTER (2).

1

Pull HANDLE BASE (7) off of CARTRIDGE (8).

Remove ADAPTER SCREW (3) from ADAPTOR (2). Pull off ADAPTER (2).

Remove SPRING CLIP (4). Lift STOP WASHER (5), turn 90˚ and replace. Replace SPRING CLIP (4).

Replace ADAPTER (2) and ADAPTER SCREW (3).

Find correct position of HANDLE ASSEMBLY (1) by adjusting male teeth on ADAPTER (2) to female teeth in HANDLE ASSEMBLY (1).

Push HANDLE (1) down onto ADAPTER (4) until it snaps into place.

6

 

90˚

7

 

3

 

 

 

 

5

4

 

2

 

 

 

 

8

12 CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.

M968635 REV. 1. 1

4

Image 4
Contents Centerset Lavatory Faucet Install Faucet With Speed Connect Drain POP-UP Drain Remove FlangeDrain Outlet Flange Gasket and POP-UP KnobAttach Cable Connector Check Operation of POP-UPMake Water Supply and Waste Connections HotcoldService Test Installed FittingCheck Drain Connections Troubleshooting Guide Cable Adjustment ProcedureUnlocked Mode Locked Mode Vandal Proof