10 TEST INSTALLED FITTING |
|
With HANDLES (1) in OFF position, turn on WATER |
|
SUPPLIES (2) and check all connections for leaks. |
|
Remove AERATOR (3). | 4 |
Operate both HANDLES (1) to flush water lines thoroughly. | 1 |
Replace AERATOR (3).
1
CHECK DRAIN CONNECTIONS
Operate
Release | 3 | |
5 | ||
connections and "P" trap for leaks. Tighten | ||
if necessary. |
|
WASTE
OUTLET
2
2 | “P” TRAP |
|
11 SERVICE
To change direction of handle:
Turn valve to OFF position |
|
Remove SET SCREW (6) with 5/64" Hex Wrench. |
|
Pull HANDLE (1) “UP” firmly to release from ADAPTER (2). | 1 |
Pull HANDLE BASE (7) off of CARTRIDGE (8).
Remove ADAPTER SCREW (3) from ADAPTOR (2). Pull off ADAPTER (2).
Remove SPRING CLIP (4). Lift STOP WASHER (5), turn 90˚ and replace. Replace SPRING CLIP (4).
Replace ADAPTER (2) and ADAPTER SCREW (3).
Find correct position of HANDLE ASSEMBLY (1) by adjusting male teeth on ADAPTER (2) to female teeth in HANDLE ASSEMBLY (1).
Push HANDLE (1) down onto ADAPTER (4) until it snaps into place.
6
| 90˚ | 7 |
| 3 | |
|
| |
|
| 5 |
4 |
| 2 |
|
| |
|
| 8 |
12 CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.
M968635 REV. 1. 1
4