Health O Meter 2000KL operation manual Set Up, Preparing the Scale for Use, Replacing Batteries

Page 11

SET UP

Preparing the Scale for Use

1.Remove protective plastic film from keypad and display.

2.Place batteries in the battery holder (see “Replacing Batteries”).

3.Plug the scale’s AC adapter into the power source.

4.Press the ON/OFF button to turn the scale on. The display will show “Health o Meter Pro-Plus” and then ”000Lb00oz”.(a) If the Stretcher weight has previously been tared out, the display will show a negative weight equivalent to the weight of the Stretcher.

5.Hang the stretcher on the Stretcher Hoops to register a 0 weight on the display. Press the Tare key if necessary.

6.Place a weight [not exceeding 400 Lb (180 Kg)] on the stretcher. The display should read the correct weight.

7.Press the KG/LB button to select the weight mode (Lb/Kg). (b) *

8.Press the Reweigh button; the scale should perform the weighing process again. The display should read “WEIGHING” until the weight calculation is complete and the weight is displayed.

9.Remove the weight from the stretcher, the scale will return to zero and the display will read “ZERO” on the left upper side of the screen along with ”000Lb00oz”.

10.Disconnect the scale’s AC adapter from the power source, and the scale will switch to battery power.

Note: If the set up procedure failed, refer to the troubleshooting instructions. If the problem is not corrected, refer to qualified service personnel.

(a)To adjust the display backlight and/or contrast, please refer to page 19.

(b)To change the display mode in pounds to fractions or decimals, please refer to page 14.

Replacing Batteries

Figure 6. Replacing Batteries

(refer to the Parts List on page 25 for details on parts followed by # )

1.Unplug the scale.

2.Remove the battery cover from the display assembly.

3.Disconnect battery holder cable connector from the scale-battery connector.

4.Carefully remove the battery holder by sliding it out of the display assembly.

5.Replace the batteries with new ones.**

6.Carefully slide the battery holder into the display assembly.

7.Plug the battery holder cable connector to the scale-battery connector.

8.Attach the battery cover to the display assembly and install the screw.

*To change the scale default units to kilograms, or to deactivate the LB/KG button, please contact Technical Support at 1 800 638-3722 or +1 708 598-9100.

**We recommend the use of EVEREADY Energizer® e2TM batteries.

10

Image 11
Contents PRO Plus Stretcher Scale Table of Contents Do not leave patients unattended while on the scale General SpecificationsScale Specifications Assembly Instructions Knob Attaching the Display and Scale to the Patient Lifter Assembly Instructions Assembly Instructions Assembly Instructions Replacing Batteries SET UPPreparing the Scale for Use Operation Instructions Operation Instructions Description Function Only applies to pound values, not the metric values Weight Display ModeMenu Removing the Tare Tare WeightData Management Automatic TareEnter Scale Settings Operation Instructions System Settings System Test User Settings Operation Instructions Disconnect the scale from the AC power source MaintenanceMaintenance CleaningSymptom Possible Cause Corrective Action TroubleshootingOperator Action Display Calibration PathExploded View of Scale continue Description Qty Parts ListTo get Warranty Service WarrantyLimited Warranty What does the Warranty Cover?

2000KL specifications

The Health O Meter 2000KL is a sophisticated and reliable weighing scale designed for professional healthcare settings, such as hospitals and clinics. With a sleek and sturdy design, this scale caters specifically to the needs of medical professionals who require accurate and efficient patient assessments.

One of the standout features of the Health O Meter 2000KL is its high weight capacity. With the ability to measure individuals weighing up to 550 pounds, it accommodates a diverse patient population. This ensures that healthcare providers can rely on a single device to cater to various body types and sizes, which is essential in maintaining a standard of care.

The 2000KL model incorporates a large, easy-to-read digital display that provides quick weight readings. The display is backlit to improve visibility, especially in low-light environments. This feature guarantees that practitioners can obtain measurements swiftly, which is crucial during busy patient visits.

In terms of technology, the Health O Meter 2000KL utilizes advanced load cell technology, which offers precise measurements and stability. This technology minimizes the impact of external factors that could skew weight readings, thus enhancing the accuracy of weight assessments. Furthermore, the scale also comes equipped with automatic shut-off features to conserve battery life, making it economical for continuous use in clinical environments.

Another significant characteristic of the 2000KL is its user-friendly interface. Healthcare professionals can quickly operate the scale without extensive training, which allows for seamless integration into clinical workflows. It features a low-profile platform that enables easy access for patients, particularly those with mobility issues.

Moreover, the Health O Meter 2000KL is built with safety and durability in mind. Its robust construction ensures long-term reliability, maintaining accuracy and performance under the demands of a busy healthcare setting. The non-skid surface of the platform also promotes patient safety by preventing slips during weighing.

In conclusion, the Health O Meter 2000KL stands out as a high-quality, reliable weighing scale that combines innovative technology with practical features. Its high capacity, accurate load cell technology, easy-to-read display, and user-friendly design make it an excellent choice for healthcare providers focused on delivering efficient and accurate patient care. This device not only streamlines the weighing process but also enhances the overall patient experience in clinical settings.