Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES manual Data Format, Transmission example

Page 22

EXCELL PRECISION CO., LTD.

(3) Data Format

Stable transmission (

 

 

 

 

 

 

 

 

 

 

) / Continuous transmission (

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Press the

 

key to transmit (

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9 10 11 12 13 14

15 16 17 18

kg/lb

HEAD 1 ,

HEAD 2 ,

DATA

UNIT

CR LF

 

HEAD 1 ( 2 BYTES )

 

HEAD 2 ( 2 BYTES )

OL

-

Overload , Under load

TR

-

TARE Mode

ST

-

Display is Stable

NT

-

NET Mode

US

-

Display is Unstable

GS

-

GROSS Mode

DATA (8 or 9 BYTES)

2D ( HEX ) = “ ” ( MINUS )

2E ( HEX ) = “ . ” ( DECIMAL POINT )

UNIT ( 2, 3 or 4 BYTES )

kg

= 6B ( HEX )

; 67 ( HEX )

 

 

lb

= 6C ( HEX )

; 62 ( HEX )

 

 

tl.T

= 74 ( HEX )

;

6C ( HEX )

;

2E ( HEX ) ; 54 ( HEX )

hkg

= 68 ( HEX )

;

6B ( HEX )

;

67 ( HEX )

Transmission example:

1. The gross weight (+0.876kg) shows as below, after stable: (in the tare mode)

S

T

,

G

S

,

+

0

.

8

7

6

k

G 0D 0A

HEAD 1 ,

HEAD 2 ,

DATA

UNIT CR LF

2. The net weight (-1.568lb) shows as below without weight stability: (Not in the tare mode)

U

S

,

N

T

,

-

1

.

5

6

8

l

b 0D 0A

HEAD 1 ,

HEAD 2,

DATA

UNIT CR LF

3. The net weight (+0.876kg) shows as below, after stable: (in the tare mode)

S T

,

T R

,

+

0

.

8

7

6

k G 0D 0A

HEAD , HEAD ,

DATA

UNIT C LF

V1.0

20

SM2020010426

Image 22
Contents Digital High Precision Weighing Scales Page Table of Contents Relay Output Before Using the Scale Preparing to USE the ScaleFeatures IntroductionPower Consumption SpecificationsLOW Battery Warning LCD Display Symbols LOWKeyboard Function UnitsDisplay Backlight Weighing ModeOperation ZeroII. Recall Totalised Weight Values Weight TotalisingIII. Clear Totalised Weight Values II. Recall the semi-auto tare value Deduction of the Container WeightWeight of the container is unknown Tare III. Clear the semi-auto tareRecall the pre-set tare value IV. The weight of the container is known Pre-set tareVI. Clear the pre-set tare value Buzzer Setting Check WeighingClear the check weighing settings IV. Recall the check weighing settingIII. High/OK/Low indications Counting Function SamplingConfiguration Settings CHECK-WEIGHING Configuration Actiondisplay DescriptionRS-232 Setting Exit Configuration Settings RS-232 25 Pin ‘D’ type Pin Description RS-232 and Relay Output RS-232 or Serial Printer OutputRS-232 Interface Format Data Format Transmission example+100.0 kg Key to Relay Pin Description Relay OutputRelay Output Connection IllustrationPower Source Illustration Connection Setting