D4028/D4032 Digital Scale
Mounting
The digital scale can be mounted to machinery in various ways. The goal is to attach either the display unit or scale body to a fixed machine part and the other component to the movable machine part. This allows you to measure the relative distance the movable machine part travels.
IMPORTANT: Choose the digital scale model that has a scale body longer than the full travel of the parts being measured. This will ensure that the display unit is not damaged as the machine parts move through their full range of motion.
Calibration
When the digital scale is properly attached to the machine, bring the movable machine part to the starting position, then press the ON/Zero button to zero the display. Position the movable machine part a known distance from the starting point, then use the decreasing and increasing buttons to make the display reading agree with the known distance.
Battery
If the digital display does not come on or it flashes, the battery voltage is low. Turn the unit OFF, remove the battery compartment cover by sliding it to the right, then replace the battery.
Troubleshooting
Problem | Possible Cause | Corrective Action | |||
Flashing digits. | Low battery. | Replace the battery. | |||
|
|
| |||
Frozen digits. | Internal circuit error. | Remove battery, wait | |||
|
| 30 | seconds, | then | |
|
| replace battery. |
| ||
No display. | Low battery voltage; | Replace | battery; | ||
| poor contact. | make sure the bat- | |||
|
| tery | contacts | are | |
|
| clean. |
|
|
NOTICE
The Model D4028/D4032 digital scale is not designed to be used around liquids of any kind. Exposing the display unit to liquids could cause permanent damage to the internal electronics, which will not be covered under warranty.