NuTone CI370 installation instructions Final System Check

Page 2

4. Refer to Figure 4. Connect the red striped wire of the

SCREW

 

 

 

2-conductor low voltage cable to the unused terminal

TERMINAL

 

 

 

 

 

 

 

screw on the inlet. Connect the remaining wire to the black

 

 

 

 

pig tail wire. Cap off both wires using wire nut (supplied).

 

 

 

 

NOTE: The LED indicator light used in the CI370 is polarity

 

 

 

 

sensitive. If the 2-conductor cable used to connect the inlet to

 

RED

 

 

the power unit does not have a polarity marking and the

 

STRIPED

 

 

 

WIRE

 

 

CI370 is wired backwards, no damage will result; however,

 

 

 

 

WIRE

 

 

the indicator will light RED instead of GREEN when the hose

 

NUT

 

 

 

 

 

 

is inserted into the inlet. To correct this condition, simply

 

BLACK

 

 

reverse the 2-conductor connections at the CI370 inlet.

 

PIG TAIL

 

 

 

FIGURE 4

 

FIGURE 5

5. Guide excess wire back through the hole in inlet bracket

 

 

 

 

 

 

and flanged fitting.

 

 

 

 

6. Refer to Figure 5. Place inlet into mounting bracket and

 

 

 

 

secure.

 

 

MODEL 365C

 

NOTE: When wall inlets are installed in walls that are less

 

 

DOUBLE FLANGED

 

 

 

TEE

 

than 12" thick or when inlets are installed back-to-back in

 

 

 

WALL

a wall, the tube of the wall inlet may extend into elbow

 

 

 

 

 

 

INLET

area of the flanged fitting and cause blockage. Shorten

 

 

 

 

 

 

 

the wall inlet tube to prevent this condition. Refer to

 

 

 

 

Figure 6.

 

 

 

 

For extra thick walls, use Model 399 extension sleeves to

 

 

 

 

connect inlet to the flanged fitting.

 

 

 

 

FINAL SYSTEM CHECK

 

 

 

 

Be sure all inlets are closed and soil bag is in place. Check switch on power

 

CUT OFF

MOUNTING

unit for manual on/off operation.

 

 

APPROX.

 

 

BRACKET

 

WALL

34” OF WALL INLET

Check each wall inlet to be sure contacts activate indicator light and power unit

 

TUBE

 

 

 

FIGURE 6

when hose is inserted. A short piece of wire can be used to short contacts in wall

 

 

 

 

 

inlet together to activate power unit. Check each wall inlet and tubing connection

 

 

 

for air leaks. Check power unit for leaks around inlet tube and dirt receptacle.

 

 

 

Note:

 

 

 

 

If indicator light is RED when the hose is inserted, reverse the wiring of the 2-conductor cable at the CI370 inlet (see fig 4).

For a hose that has an ON/OFF switch on the hose, the light on the inlet will be activated only when the hose is switched “ON”.

FLANGE

INLET

361

FITTING

SEAL

MOUNTING

 

 

BRACKET

 

 

PLASTER

 

 

FRAME

 

 

2916

 

 

WALL

 

 

INLET

 

 

3116

FIGURE 7

 

 

Product specifications subject to change without notice. 4820 Red Bank Road, Cincinnati, Ohio 45227 • 1140 Tristar Drive, Mississauga, Ontario, Canada L5T 1H9 Printed in U.S.A., Rev. 4/01, Part No. 88384

Image 2
Contents Installation Wall Inlet InstallationFinal System Check Installation D’UNE Prise Murale Cadre De MontageVérification Finale DU Système 31⁄16