Fluke 1060AM-NM-LRVAR manual Instructions, General Description, Specifications

Page 7

Instructions

General Description 2

Section 2

Instructions

2.1 General Description

Refer to 1060-005 drawing located in Appendix A .

The Fluke Biomedical local , remote , and flasher alarms are used in conjunction with the Victoreen Model 1060AM-NM-LR. The operating range of this system is 0.01 mR/hr to 1R/hr. The red halogen lamps and the flashing yellow sign provides a remote (75ft) and a local visual alarm indication. The green incandescent lights operate at half power and indicate normal operating conditions while in a radiation field of less than 2mR/hr +/- 10%.

An efficient dual led (red / green) operates in a similar fashion and shall alert personnel of a bulb burn out in either the local or the remote alarms.

The Local alarm also includes two female power connectors (J1 and J2) each with a set of normally closed contacts. J3 is a male connector with a dust cover that interfaces with the 1060am-nm-LR . A ½ inch conduit fitting is provided for the hot (L1), neutral (L2), and earth ground connections.

The Remote and Flasher alarm both have a single male plug connector (P1) to interconnect with the local alarms normally closed contacts. Conduit fittings provide access for the neutral (L2) and earth ground terminations. The Flasher alarm includes an AC solid state timer that switches two 25W halogen lamps at a frequency of about forty flashes per minute.

2.2 Specifications

Dimensions

Local Alarm

Remote Alarm

Flasher Alarm

(H x W x D )

pn 1060-024

Pn 1060-034

Pn 1060-026

 

9 x 6.3 x 6.75

9 x 6.3 x 6.75

10 x 14x 2

in (cm)

(22.9 x 16.0 x 17.1

(22.9 x 16.0 x

(25.4 x 35.6 x 5.1)

 

 

17.1)

 

Weight lbs (Kg)

3 lb (1.4)

2.5 lb (1.1)

3 lb (1.1)

Operating

-32 deg to 122

-32 deg to 122

-32 deg to 122

Temperature

deg

deg

deg

F (C)

 

 

 

 

(0 deg to 50 deg)

(0 deg to 50 deg)

(0 deg to 50 deg)

Relative Humidity

0 to 90%

0 to 90%

0 to 90%

Non condensing

 

 

 

2-1

Image 7
Contents 1060AM-NM-LRVAR Local, Remote, and Flasher AlarmsFluke Biomedical Table of Contents Blank Introduction Procedures, Warnings and Cautions1060AM-NM-LRVAR Instructions SpecificationsGeneral Description Storage Receiving InspectionInstallation Electrical interface Operation Blank Maintenance and Cleaning Troubleshooting Applicable Drawings and Parts List Applicable Drawings and Parts ListFluke Biomedical