Pressure Tap Installation for ThermoLazer
Pressure Tap Installation for ThermoLazer
1. Close manual gas shutoff valve on propane tank.
9.Install new gas line (3) by screwing into gas safety valve adapter fitting (164) and screwing into adapter fitting (4). Screw in until gas tight.
ti14128a
2. Disconnect gas supply hose (99) from propane tank.
| 8 | 14 | 164 |
|
| ||
|
| 5 |
|
ti22114a | 7 |
|
|
99
4
3
ti22097a
3.Remove and discard existing gas line (3) by unscrewing from elbow fitting (161) and unscrewing from gas safety valve adapter fitting (164).
10. Connect gas supply hose (99) to propane tank.
99 |
ti14411b
4.Remove and discard existing elbow fitting (161) by unscrewing from manual gas shutoff valve (9).
11. Open manual gas shutoff valve on propane.
9
ti22104a
164
ti14127a
161 3
5.Apply pipe sealant to elbow fitting (8) and screw into manual gas shutoff valve (9). Screw in until gas tight. Position fitting as shown.
6.Apply pipe sealant to adapter fitting (7) and screw into tee fitting (11). Screw in until gas tight.
7.Apply pipe sealant to adapter fitting (4) and screw into tee fitting (11). Screw in until gas tight.
8.Apply pipe sealant to adapter fitting (7) and screw into elbow fitting (8). Screw in until gas tight. Posi- tion fittings as shown.
12.Check gas lines for gas leaks (see ThermoLazer Operation Manual).
332653A | 3 |