SENSOR OPEN CIRCUIT OR
OVERRANGE/UNDERRANGE INDICATION
If the sensor is open circuit, the display will show
INSTRUMENT ACCURACIES
All ±1 digit.
Model HH2106T
±0.2°C/0.4°F over range
Model HH2146T
±0.2% rdg ±0.1°C/0.2°F over range
COMMON SPECIFICATION
Dimensions: 155 x 67 x 40mm/6.1 x 2.6 x 1.6 inches
Weight: 180g/6.4 oz
INSTRUMENT CALIBRATION
Please note that the HH2100 series range of thermometers can only be calibrated by an Omega Service Center. For details of your nearest center please refer to the end of these operating instructions.
The overall performance of the instrument is obtained by combining the stated accuracy and any uncertainty due to the measurement process.
GB
Some of the options described may not apply to this instrument. Please check the functions of the instrument you have purchased before proceeding.
Model | HH2106T | HH2146T |
Sensor | T | Thermistor |
|
|
|
C/F | X | X |
Hold | Y | Y |
XInstrument supplied
YFunction available
Refer to rear of instrument for the temperature ranges.
INSTRUMENT OPERATION
BATTERIES
Two AA or equivalent cells. Follow instructions on reverse of instrument for fitting/replacement.
When symbol appears on display, replace batteries.
IP67 RATING
The waterproof rating for this product will not be maintained unless the screws holding the battery compartment are firmly tightened when inserting or replacing batteries.
ON - OFF
Press ON key for on and OFF key for off. Automatic switch-
off after 12 minutes. If key is held when unit is switched on, automatic
PROBE CONNECTION
The following probes should be used with the HH2100 Series Thermometers.
Probe Code |
|
|
Sensor Type | Thermistor | T |
|
|
|
Tip Dimensions | 120mm x 3.3mm | 90mm x 3.3mm |
|
|
|
Handle Length | 143mm | 143mm |
|
|
|
Units used with | HH2146T | HH2106T |
THERMISTOR PROBE CONNECTION POINTS (NO POLARITY)
THX-HH2106T
TYPE ‘T’ THERMOCOUPLE
CONNECTION POINTS
BROWN +VE | WHITE |
THERMISTOR | THERMISTOR |
FANWAL PART No.
R.T. CURVE 2252 0Hms @ 25°C
WARNING - Do not bring probe into contact with any service connected to a hazardous voltage (i.e. a voltage exceeding 30 volts RMS or 42.4 volts peak with respect to either earth or ground). Ensure that the probe is suitable for the application, paying particular attention to the temperature range and type of thermocouple. Connect probe plug into the socket at top of instrument.
NOTE: Only probe listed should be used with the HH2100 series thermometer range.
BACKLIGHT
Press and hold ON key.
DISPLAY
MULTIFUNCTION |
| MULTIFUNCTION |
| MULTIFUNCTION | ||||||||||||
TIME LOG |
| NUMERIC |
|
|
|
|
|
|
|
| N S | |||||
|
|
|
|
|
|
|
|
| ||||||||
HH:MM |
|
| ENTRY | RANGE |
| FAST |
|
|
|
|
| |||||
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| NE A/R | NS | |
| OK? |
| |
BATTERY | YES | CELSIUS CAL | ENTER |
|
| CHANNEL |
|
|
| SELECTION FAHRENHEIT |
|
DISPLAY HOLD
Pressing key freezes the display and will appear on the display. Press key again to return to normal display.
TEST RESULTS
Type T to BS 4937/DIN 43710 | [ | ] | |
Thermistor |
| [ | ] |
Model: | Serial No: | .......................................... |
This instrument has been calibrated in: ..................................
Tested by: ...............................................................................
This instrument has been designed to meet environmental condition:
Norm IP67 [ | ] | |
|
|
|
INPUT |
| READING |
|
|
|
|
|
|
®
An OMEGA Technologies Company
Servicing USA and Canada: Call OMEGA Toll Free
USA | Canada |
One Omega Drive, Box 4047 | 976 Bergar |
Stamford, CT | Laval (Quebec) H7L 5A1 |
Telephone: (203) | Telephone: (514) |
FAX: (203) | FAX: (514) |
Sales Service:
Customer Service:
Engineering Service:
TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA
Servicing Europe: United Kingdom Sales and Distribution Centre
25 Swannington Road, Broughton Astley,
Leicestershire LE9 6TU, England
Telephone: 44 (1455) 285520 FAX: 44 (1455) 283912
The OMEGA Complete Measurement and
Control Handbooks & Encyclopedias
Temperature | Data Acquisition Systems |
Pressure, Strain & Force | Electric Heaters |
Flow and Level | Environmental Monitoring |
pH and Conductivity | and Control |
Call for your FREE Handbook Request Form today: (203)