Braun IRT 1020 manual Temperature taking hints, Troubleshooting, LCD-Display Situation

Page 8

Temperature taking hints

• It is important to use an ear tug, point the

thermometer lens toward the eardrum and

gently insert far enough into the ear canal to

obtain an accurate reading.

• When taking a temperature on another

person, it may be more difficult to

consistently position the thermometer in

their ear. If the person whose temperature

Troubleshooting

The Braun ThermoScan Instant Thermometer has been designed to provide feedback to ensure proper usage and accurate temperature taking. In many cases this means that instead of displaying a temperature that is not meaningful, a message will be displayed that will help you take corrective action. These messages are outlined below:

LCD-Display Situation

Solution

is to be taken is old enough, ask for

assistance in the positioning process.

• It is not uncommon for a person’s

temperature in the right ear to be slightly

different than in the left ear. When

Err 1

Appears after on-button is

 

pushed if the temperature of

 

the Braun ThermoScan is

 

not within its operating

 

range. 16°C to 40°C (61°F to

 

104°F).

Move the thermometer to a room within the 16°C to 40°C (61°F to 104°F) operating range for 30 minutes and retake temperature.

monitoring temperature during illness, use

the same ear to maintain a constant frame

of reference.

• If a person has been sleeping on one ear for

an extended period of time, the temperature

of that ear may measure higher than

Err 2

appears after pushing the

 

activation button if

 

temperature measurement

 

is not within typical human

 

temperature range of 34°C-

 

42,2°C (93,2°F to 108°F).

Be sure a lens filter is attached and the thermometer is properly inserted, fully sealing off the ear canal. Take the temperature again.

normal. Wait a few minutes before taking a

temperature to allow the ear to stabilise.

• The best temperature measurements are

taken when the ear is free of obstruction. If

you suspect an obstruction or excessive

earwax build up, contact your physician.

• The normal range for ear temperatures

taken with a Braun ThermoScan Instant

Thermometer is 35.8°C to 38°C (96.4°F to

Err 3

Appears after the activation

Take the temperature

 

button is pushed if it is not

again by slowly depressing

 

held down for a full second.

the activation button and

 

 

holding it down for one full

 

 

second.

 

 

 

Err 4

Appears after activation

Allow the thermometer to

 

button is pushed if the

remain for 30 minutes in

 

internal temperature of the

the room where the tem-

 

thermometer is changing to

perature is being taken.

 

rapidly.

 

 

100.4°F).

To protect the instrument lens, always keep

 

a lens filter attached. If the thermometer is

 

accidentally used without a filter, gently

 

clean the lens and surrounding area (see

 

instructions on page 17). It is also a good

 

idea to inspect the lens whenever you

 

replace a lens filter.

• The thermometer is designed to take

 

accurate temperatures with a lens filter

 

in place. Temperatures taken without a

 

lens filter attached will not be accurate

 

and can damage the lens. Change the

 

lens filter after each use.

Err 000

The Braun ThermoScan

 

performs a self diagnostic

 

test on is circuitry after each

 

initial activation and when a

new battery is intalled. If any faults are detected, „Err 000“ will be displayed.

Wait 2 minutes until the thermometer switches itself off automatically (blanc LCD-display). Push on-button and take temperature again. If „Err 000“ is repeated, contact Braun.

14

15

Image 8
Contents ThermoScan IRT Type Home ModelPage IRT 1020 product specifi cations Components and features Preparing the Braun ThermoScan Instant Thermometer for usePage Normal Ear Temperature Range by Age Body temperature measurementHow to use the Braun ThermoScan Instant Thermometer Children 1 Year to Adult Ear tug and positioning techniqueChildren unter 1 year Temperature taking hints TroubleshootingLCD-Display Situation Lens filter after each useThermometer Care and cleaningLens Filters For UK only GuaranteeCalibration Lot number identifi cation

IRT 1020 specifications

The Braun IRT 1020 is a highly regarded ear thermometer that has set industry standards for its precision and ease of use. Designed for families, this thermometer offers quick and accurate temperature readings, making it an essential tool for identifying fever and monitoring health in both children and adults.

One of the key features of the Braun IRT 1020 is its innovative infrared technology. This thermometer uses a sensitive infrared sensor that captures the heat generated by the eardrum and surrounding tissue, providing a reading that is not only quick but also reliable. The device takes temperature readings in just a second, which is particularly advantageous when dealing with restless children, as it minimizes discomfort and allows for a swift assessment of their health.

In terms of usability, the Braun IRT 1020 boasts a user-friendly design that includes an ergonomic shape, allowing for a comfortable grip during measurements. The thermometer is equipped with a large, easy-to-read LCD display that shows the temperature reading clearly, even in low-light conditions, which adds to its convenience during nighttime checks. This model is also designed for simple operation; with the press of a single button, users can achieve accurate results without any complicated procedures.

Another notable characteristic of the Braun IRT 1020 is its memory function. This feature allows users to store the last nine temperature readings, providing a history that is useful for tracking changes over time. This can aid parents in monitoring their child's fever progress or in making informed decisions when contacting healthcare professionals.

Moreover, the Braun IRT 1020 comes with disposable lens filters that help to maintain hygiene and ensure accurate readings by preventing contamination. This is especially important when sharing the thermometer among family members.

Durability is another highlight of this thermometer, as it is built to withstand regular use in a family environment. The Braun IRT 1020 is also clinically validated for accuracy, ensuring that users can trust the readings it provides.

In conclusion, the Braun IRT 1020 combines advanced technology with user-friendly features, making it one of the top choices for parents and caregivers looking for an effective way to monitor body temperature. Its swift, accurate results, ergonomic design, memory functionality, and hygienic features solidify its reputation as a reliable health tool in households.