Infinity CPG-INFVER01 Manufacturer/Product, CAR Enclosure, Ceilings, Handrail, Emergency Light

Page 7

 

INFINITY

Continued

Specifications for Part 5.3 Compliance

 

 

Residential Elevator

 

 

PART 4 – PRODUCT DATA

4.1 MANUFACTURER/PRODUCT

The elevator shall be the CONCORD INFINITY Residential Elevator manufactured by Concord Elevator Inc. Toll Free (800) 661-5112 and (905) 791-5555, Fax (905) 791-2222

Dealer Name ___________________________________

Number _______________________________________

Rated Load: 750 lbs. (340 kg.)

Nominal Speed: 36-fpm (0.18 m/s)

Car Dimensions: 36" W x 48" D (914 mm W x 1220 mm D)

Operation: Automatic

Gate Type: Horizontally collapsible, accordion style with 3 vision panels

Power Supply: 220 Volt, Single Phase, 30 Amps or 208 Volt, 3 Phase, 30 Amps

Travel Distance: 50 ft. (15.2 m) max __________________

Levels Served: (up to 5, max. 4 - SRE) ________________________

Number of Openings: Two (2) Maximum

Lighting Supply: 110 Volt, 1 Phase, 60 Cycle, 15 Amps

Jack Type: 1:2 Cable Hydraulic

Pump Type: Submersible with Variable Speed Valve Levelling

Device Type: Magnetic

4.2 CAR ENCLOSURE

4.2.1 WALLS

1/2" (13 mm) Melamine panels and black anodized aluminum trim.

4.2.2 CEILINGS

Architectural white with four (4) recessed incandescent down lights.

4.2.3FLOOR Plywood sub-flooring.

4.2.4HANDRAIL

Black painted oak handrail located on control panel.

4.2.5 EMERGENCY OPERATION

The elevator car shall be equipped with a battery-powered emergency lowering device and alarm that can be actuated on the failure of normal building power supply. Battery will be rechargeable type with an automatic recharging system.

4.2.6 EMERGENCY LIGHT

The car shall be equipped with an integral emergency light that will illuminate automatically in the event of a main power failure.

4.2.7 CAR OPERATING PANEL

Car operating panel shall consist of metal push buttons with halo lighting for each landing, an emergency stop button, an alarm button and a key switch. The key is removable in both the on and off position. All mounted on a #4 finished stainless steel panel. Car station panel is hinged.

4.2.8 DIGITAL FLOOR INDICATOR

Digital floor indicator located in the control panel will display the location and direction of travel (floor number) of the elevator in the shaft. (optional on SRE model)

4.2.9 CAR LIGHTING

The car lighting shall consist of four (4) low voltage recessed incandescent down lights. The failure of one lamp shall not cause the remaining lamp to extinguish.

4.2.10 AUTOMATIC LIGHTS

Overhead lights in the car compartment shall turn ON automatically when the elevator door is opened and will stay on while the elevator is in use. The elevator lights will shut off by a timer when the elevator is not in use.

4.3 DOOR LOCKS

Locks shall be electrically operated and electrically released at floor level and will remain unlocked until hall or car call is placed. When released, the locks’ lag member will drop down and close the electrical circuitry to ensure the elevator cannot move unless the door is closed and locked (a true interlock).

4.4 HALL CALL STATIONS

Provide a keyless hall call station with an illuminated call button and stainless steel cover plate for each landing.

4.5 PLATFORM TOE GUARD

A platform toe guard shall be provided at each car entrance opening to extend below the car entrance opening for safety.

4.6LEVELING DEVICE

a)The elevator shall be provided with a 2-way leveling device, which will maintain the car within 1/2" (13mm) of the landing.

b)Levelling device sensors shall be located in a position to be inaccessible to unauthorized persons.

4.7CAR GATE REQUIRED OPTION

Horizontally collapsible accordion style woodfold car gate with rattan panels and three (3) clear acrylic vision panels car gate shall enclose each car entrance.

4.8HYDRAULIC POWER UNIT

a)The pump and motor shall be the submersible type installed inside the oil tank.

b)The controller shall be integrally mounted on the power unit frame and pre-wired and tested before shipment.

c)Control circuitry to be located at the top of the oil tank.

d)The power unit control valve shall be a variable speed proportional valve type that includes all hydraulic control valving

inherently.

This valve shall incorporate the following features:

(i)Up and down acceleration and deceleration speed adjustment for smooth starts and stops.

(ii)Smooth stops at each landing shall be an inherent feature of the valve.

(iii)Adjustable pressure relief valve.

(iv)Manually operating 'DOWN' valve to lower elevator in an emergency.

(v)Pressure gauge indicating in P.S.I. and Bars.

(vi)Gate valve to isolate cylinder from pump unit.

(vii)Negative pressure switch.

4.9CYLINDER AND PLUNGER

4.9.1

The cylinder shall be constructed of steel pipe of a sufficient thickness and suitable safety margin. The top of the cylinder shall be equipped with a cylinder head with an internal guide ring and self-adjusting packing.

4.9.2

The plunger shall be constructed of a steel shaft of a proper diameter machined true and smooth. The plunger shall be provided with a stop electrically welded to the bottom to prevent the plunger from leaving the cylinder.

CPG-INFVER01 © 2004, Concord Elevator Inc. Page 7 of 12

Image 7
Contents Infinity Introduction InfinityGeneral Equipment for Residential ElevatorHoistway and Cab Configurations Hoistway Overhead Clearance Hoistway and Cab ConfigurationsTypical Hydraulic Drive Machine Room Layout Requirements of the Regulatory Agencies ScopeSystem Description Quality AssuranceCAR Enclosure Digital Floor IndicatorHydraulic Power Unit MANUFACTURER/PRODUCTRail Reactions Typical Lower Rail Bracket ConfigurationSuggested Support Wall Wood Construction Wood Hoistway ConstructionWood Construction Plan View Rail Bracket Wood Construction Sectional ViewBlock Wall 8 Minimum Masonry Construction Elevation ViewDrawing Notes Elevator Rail Support Wall