Step-by-Step Instructions

Choose a clean, dry work surface. Make sure you have all the materials needed for a test:

ONE TOUCH® BASIC® Meter

ONE TOUCH® Test Strips

PENLET® II Automatic Blood Sampler (with choice of Caps)

Sterile Lancet

IMPORTANT:

The Test Strip Holder and Test Area of the Meter must be clean, dry and lint-free.

Check the expiration date on the Test Strip package. If the date has passed, discard the Test Strips and open a new package.

If using vial Test Strips, discard unused Test Strips 4 months after opening.

If you have questions about the testing procedure, call LifeScan Technical Services.

28

Image 35
Contents OWNER’S Booklet Manuel DU Propriétaire OWNER’S Booklet Dear ONE Touch Basic Owner Page Table of Contents Taking Care of the Meter Blank Description and Use Getting StartedGetting to Know the Meter Battery Compartment Test Summary Precautions and Limitations Page Selecting the Display Language and the Unit of Measurement Setting the MeterSet the code Coding the MeterMemory Turn on the MeterMatch the Code Number Code10Checking with the Check Strip Checking the SystemStep Wait Insert Anotok redo a You must use the Check Strip Checking with Control Solution Contrl You should use the Glucose Control Solution Insert a Lancet Using the Penlet II Automatic Blood SamplerGetting a Drop of Blood Page Regular Deep Penetration Get a Drop of Blood Cock the Penlet SamplerPage Remove the Lancet Cleaning the Penlet II Sampler Insert Testing Your BloodStep-by-Step Instructions Deep Regular Press On/ Off Button to turn the Meter on Insert Test Strip Insert Wait Make sure that you Apply blood sampleAccurate results in 45 seconds After Testing Test Strip You should see a Full, dark circle Checking the Amount of Blood on the Test StripRecording Your Test Results Displaying Last Test Result HELP! Troubleshooting Memory Test Procedure MessagesInsert strip Wait Apply sample 45, 44 Ok high Contrl Insert side1R23 Error MessagesBattry Clean test area Contrl Error1 retest Error2 retest Message Problem What to do Insert insert insert Message Problem What to do Anotok redo a Not enough blood retest Not okStrip Redo aRemove Reset code Taking Care of the Meter Important Infection Control Information Daily Meter Check Cleaning the MeterRemove Test Strip Holder Clean Test Area Clean Test Strip HolderPage Replace Test Strip Holder Insert insert Battery ReplacementReplacing the battery OV-6 Page Why should I test my blood glucose sugar? Questions and AnswersWhat can I do to be sure I get accurate test results? How often should I test my blood glucose?Should my test results always be the same? Page What do I do if test results still seem too low or too high? Factors which could lead to severe dehydration Consult a Physician Immediately Page Page Performance Characteristics SpecificationsGuarantee and Warranty Page Index LifeScan Technical Services Canada 1 800 USA 1 800 LifeScan Technical Services Canada 1 800 USA 1 800 Canada 1 800 A 800
Related manuals
Manual 77 pages 38.04 Kb Manual 103 pages 12.78 Kb