Troubleshooting Diagnosis Chart
FUNCTION |
| POSSIBLE CAUSE | REMEDY | |
|
|
| ||
10.00 | 10.11 Poor plug connections | Check harness connectors A1 and A2, E1, N1, | ||
|
| N2, E1, F1 and F2. | ||
BARRIER WILL |
|
| ||
|
|
| ||
NOT OPERATE | 10.12 | Faulty barrier actuator motor or | Check power at motor. Adjust or replace actuator | |
UP OR DOWN | ||||
| actuator out of adjustment | if necessary. | ||
WITH HAND- |
| |||
|
|
| ||
HELD PENDANT |
|
|
| |
OR OVERRIDE | 10.13 Bad power and ground | See 1.00 | ||
SWITCHES | ||||
|
|
|
| |
|
|
|
| |
11.00 |
|
|
| |
BARRIER | 11.11 | Faulty Outer Barrier switch | Check diagnostic LCD for Outer Barrier Switch | |
OPERATES WITH | ||||
OVERRIDE |
|
| status. Adjust or replace switch as necessary. | |
SWITCH BUT |
|
|
| |
WILL NOT GO | 11.12 | Barrier occupied | Remove weight from barrier. See Outer Barrier | |
UP WITH HAND- |
|
| Occupied Calibration on page 5. | |
HELD PENDANT |
|
|
| |
|
|
|
| |
|
|
|
| |
12.00 | 12.11 | Faulty Pressure Transducer | Check Pressure Transducer. Adjust or replace | |
BARRIER |
|
| as necessary. See Ground Sense Calibration on | |
OPERATES |
|
| page 5. | |
WITH OVER- |
|
|
| |
RIDE SWITCH | 12.12 | Stow switch out of adjust- | Check diagnostic LCD for Stow switch status. | |
BUT WILL NOT |
| ment or defective | Adjust or replace as necessary. | |
GO DOWN WITH |
|
|
| |
12.13 | Full Out switch out of | Check diagnostic LCD for Full Out switch status. | ||
PENDANT | ||||
| adjustment or defective | Adjust or replace as needed. | ||
|
| |||
|
|
|
| |
|
|
|
| |
13.00 | 13.11 No power going to switches | Check power on connector A1, pins 1 and 2. | ||
SWITCHES | ||||
|
|
| ||
DO NOT | 13.12 | Faulty wiring | Check continuity of wires from switches to connector | |
CHANGE | ||||
|
| A2. | ||
STATE IN |
|
| ||
|
|
| ||
DIAGNOSTIC | 13.13 | Faulty connections | Check for proper connections on each switch and | |
MODE | ||||
|
| on each connector on the harnesses. Replace con- | ||
|
|
| ||
|
|
| tact if necessary. See diagram on following page. | |
|
|
|
| |
|
|
|
| |
14.00 | 14.11 | Faulty wiring | Check for proper wiring to door openers. | |
DOORS | ||||
DO NOT |
|
|
| |
OPEN |
|
|
| |
|
|
|
| |
|
|
|
| |
15.00 | 15.11 | Lift Out switch out of adjustment | Lift not stowed fully. Adjust lift out switch or | |
| or defective | replace. | ||
DOORS |
|
|
| |
DO NOT |
|
|
| |
CLOSE |
|
|
| |
|
|
|
|
Page 17