Braun NUVL603C service manual Barrier will Not Operate

Page 19

Troubleshooting Diagnosis Chart

FUNCTION

 

POSSIBLE CAUSE

REMEDY

 

 

 

10.00

10.11 Poor plug connections

Check harness connectors A1 and A2, E1, N1,

 

 

N2, E1, F1 and F2.

BARRIER WILL

 

 

 

 

 

NOT OPERATE

10.12

Faulty barrier actuator motor or

Check power at motor. Adjust or replace actuator

UP OR DOWN

 

actuator out of adjustment

if necessary.

WITH HAND-

 

 

 

 

HELD PENDANT

 

 

 

OR OVERRIDE

10.13 Bad power and ground

See 1.00

SWITCHES

 

 

 

 

 

 

 

 

11.00

 

 

 

BARRIER

11.11

Faulty Outer Barrier switch

Check diagnostic LCD for Outer Barrier Switch

OPERATES WITH

OVERRIDE

 

 

status. Adjust or replace switch as necessary.

SWITCH BUT

 

 

 

WILL NOT GO

11.12

Barrier occupied

Remove weight from barrier. See Outer Barrier

UP WITH HAND-

 

 

Occupied Calibration on page 5.

HELD PENDANT

 

 

 

 

 

 

 

 

 

 

 

12.00

12.11

Faulty Pressure Transducer

Check Pressure Transducer. Adjust or replace

BARRIER

 

 

as necessary. See Ground Sense Calibration on

OPERATES

 

 

page 5.

WITH OVER-

 

 

 

RIDE SWITCH

12.12

Stow switch out of adjust-

Check diagnostic LCD for Stow switch status.

BUT WILL NOT

 

ment or defective

Adjust or replace as necessary.

GO DOWN WITH

 

 

 

HAND-HELD

12.13

Full Out switch out of

Check diagnostic LCD for Full Out switch status.

PENDANT

 

adjustment or defective

Adjust or replace as needed.

 

 

 

 

 

 

 

 

 

 

13.00

13.11 No power going to switches

Check power on connector A1, pins 1 and 2.

SWITCHES

 

 

 

DO NOT

13.12

Faulty wiring

Check continuity of wires from switches to connector

CHANGE

 

 

A2.

STATE IN

 

 

 

 

 

DIAGNOSTIC

13.13

Faulty connections

Check for proper connections on each switch and

MODE

 

 

on each connector on the harnesses. Replace con-

 

 

 

 

 

 

tact if necessary. See diagram on following page.

 

 

 

 

 

 

 

 

14.00

14.11

Faulty wiring

Check for proper wiring to door openers.

DOORS

DO NOT

 

 

 

OPEN

 

 

 

 

 

 

 

 

 

 

 

15.00

15.11

Lift Out switch out of adjustment

Lift not stowed fully. Adjust lift out switch or

 

or defective

replace.

DOORS

 

 

 

DO NOT

 

 

 

CLOSE

 

 

 

 

 

 

 

Page 17

Image 19
Contents Series Congratulations Warranty and Registration InstructionsContents Platform Lift TerminologySwitch and Sensor Locations Certification Checklist Adjustment Procedures Adjustments and CalibrationObar Floor Level Switch Adjustment Floor Level and Inboard Locator AdjustmentsInboard Locator Adjustment Tate C Inboard Locator Linkage Rod Adjustment LO Light Oil Lubrication DiagramCycles Maintenance and Lubrication Schedule1500 4500 Cycles Function Possible Cause Remedy Troubleshooting Diagnosis ChartLift will Barrier will Not Operate Contact Removal This page intentionally left blank Power Pack / Lift Housing Lift Wiring Schematic MainUnfold Lift Wiring Schematic Lift AccessoriesQty Description Hydraulic Parts ListHydraulic Diagram Pump Module Parts List Pump Module Diagram Complete Lift Exploded View Repair Parts List Lift Housing Detail Exploded View Lift Carriage Detail Exploded View Lift Platform Detail Exploded View Braun Limited Warranty HOW to GET Service Warranty Registration and Miscellaneous This page intentionally left blank Providing Access to the World CJKA+%8