BASIC OPERATION OF YOUR ZONED COMFORT CONTROL SYSTEM
Your Aprilaire Zoned Comfort System will allow you to increase your comfort by directing conditioned air to separate areas (zones) based upon each zones thermostat setting. To operate the system, just set or program each zones thermostat to your desired comfort and
When there is a heating or cooling call from any zone, the appropriate heating or cooling equipment will be turned on. The dampers in zones not requiring heating or cooling will close and the conditioned air will be directed to the calling zone(s) until the thermostat is satisfied.
Aprilaire Zoned Comfort Control is a heat call priority system. This means that there are certain times when heating calls will take precedence over cooling calls. This occurs if two calls for opposing modes exist simultaneously while the system is idle, in which case the heat call will be satisfied first. In all other cases a
Your zone control system is designed to direct conditioned air only to the rooms served by that zone’s thermostat. However, due to the open design of today’s homes, it may not be possible to maintain drastic temperature differences between zones. Closing interior doors is a good way to reduce the air exchange between zones and increase the temperature difference between them.
The following sections describe how to make Heating, Cooling, and Emergency Heat calls as well as how your Aprilaire Intelligent Zoned Comfort Control System can control the other pieces of your HVAC system.
HVAC CONTROL DETAILS
HEATING OPERATION (ALL MODELS OF EQUIPMENT)
To start heating:
1.Set your Model 8570 programmable thermostat to the Heat mode. This is accomplished by selecting HEAT from the Mode Menu. Consult the Model 8570 Owner’s Manual for details.
03/31/04 8:32 AM |
|
OUTDOOR | OFF |
20˚ | FAN AUTO |
71˚
INFO MENU
MAIN MENU
SET DATE AND TIME HOLD
PROGRAM FAN
MODE - HEAT/COOL/ETC.
SETTINGS
EXIT SELECT
MODE MENU
OFF
AUTO
HEAT
COOL
EMERGENCY HEAT
BACK SELECT
03/31/04 8:32 AM |
|
OUTDOOR | HEAT MODE |
20˚ | FAN AUTO |
71˚SETPOINT HEAT 70
INFO MENU
2.Adjust the thermostat set point to a temperature higher than the displayed room temperature, using the Up button, so that a Heat call is initiated. Again, consult your thermostat Owner’s Manual for details on how to do this properly.
03/31/04 8:32 AM |
|
OUTDOOR | HEAT MODE |
20˚ | FAN AUTO |
HOLD THIS
TEMPERATURE UNTIL 4:00PM
HOLD TIL 4:00PM |
|
OUTDOOR | HEATING |
20˚ | FAN ON |
68˚
INFO MENU
SETPOINT HEAT 68
HEAT
72˚
BACK SAVE
68˚SETPOINT HEAT 72
RESUME PROG. MENU
The LED labeled “HEAT”, on the zone panel enclosure will indicate if the board is making a call for heat. If the equipment does not come on right away, it may be due to the