To change the coaxial configuration go to the TDR function and press the Setup key.

Use the and keys and the Blue numeric keys to enter the length of cable to analyze. Enter a length longer than the cable being tested but as close as possible to the total length of the cable.

When the correct information is displayed on the

Auto TDR screen, press the key to start the analysis. The 900AST performs tests to determine if the cable is shorted, open circuited, or has a resistance fault.

Note: Auto TDR operates from a captured trace. The trace is not ‘live’ as in the standard TDR mode.

Auto TDR Resistive Faults

Note: Resistance faults are very difficult to detect using TDR techniques. If a resistance fault is detected, the 900AST tester prompts you to consider using the RFL (Resistance Fault Locate) function as shown below.

Auto TDR Trace Analysis

If the Auto TDR detects an open circuit, the cursor is positioned at the location of the open circuit and OPEN is displayed below the trace. If the Auto TDR detects a short circuit or low resistance fault, the cursor is positioned at the location of the short circuit and SHORT is displayed below the trace.

15

Image 15
Contents December 78-8135-6156-6-A Advanced Systems Tester 900AST Series Coaxial Wire TestingSetup for Use Keypad Function Keys Contrast and BacklightingCAUTION Connecting to Coaxial Wires for TestingTDR Setup Single Trace TDR Test ModesMemory Dual TracePeak Move Cursor TDR Save for Coaxial Wiring ComparisonEvent Recognition Open Circuit Target ContactSoak Test Resistance Faults on Coaxial CableShort Circuit Branch CircuitAuto TDR for Coaxial Fault Detection Auto TDR Resistive Faults Auto TDR Trace Analysis Restoring the Aircraft After Testing/ Troubleshooting Care and MaintenanceImportant Notice