Semi-recessed fixtures shown without thermal protectors

Installation Instructions

Sheet 2 of 4

 

 

 

Vault w/ visor

C-Scroll w/ visor

Roundel w/ visor

These installation instructions are valid with the above Ametrix styles.

Small, INDOOR

SRR

(Semi-Recessed, Remote ballast)

Visor and Non-Visor

Warning: Before starting any work ensure that all sources of power are turned off. All work must meet local/national codes and be performed by a certified electrician. Do not mount fixtures vertically.

2.

Securing fixture to ceiling tile

 

#10-32 x3/8"

 

 

Pan head screw

Universal

 

(4x)

bracket

Ceiling tile

Fixture assembly

1.If possible, remove ceiling tile from grid to facilitate fixture installation.

2.Using cut out dimensions provided on page four(4), cut appropriate size opening in ceiling tile.

3.Insert fixture assembly into cut out in ceiling tile.

2.

Wiring the fixture

 

(drywall)

 

Conduit from power source. (by others)

Cover plate

#10-32 x3/8" Pan head screws (2x)

Fixture housing

1.Using cut out dimensions provided on page four(4), cut hole into dry wall and feed power wire to hole.

2.After removing fixture head, loosen #10-32 x3/8" Pan head screws and remove cover plate closest to power feed.

3.Knock out appropriate hole for conduit and attach as shown on page three(3).

4.Replace cover plate and secure with #10-32 x3/8" Pan head screws and press fixture housing into hole in drywall.

3.Replacing brackets on fixture housing

(ceiling grid)

#10-32 x 3/8" Pan head screws (4x)

Universal brackets (2x)

1.Loosely reattach brackets to both sides of fixture housing.

2.Press brackets flush to ceiling tile and secure using #10-32 x 3/8".

3. Securing the fixture in drywall

1/4-20 x1 1/2" Pan head screw

Safety wires

(by others) (4x)

1.Prior to pushing fixture into hole in drywall, tie off fixture housing to structure using saftey wire(by others) as show on page three(3).

2.Gently push fixture housing into hole and tighten 1/4-20 x 1 1/2" Pan head screw from inside fixture housing to tighten drywall bracket around drywall.

3.Connect appropriate wires from fixture head and ensure all wires are properly matched.

4.Replace fixture head assembly on keyhole screws and tighten.

ADY071459 REV B (ECN80481)

Image 2