Toshiba CTX28 manual CTX100 Cabinet Slots

Page 49

Strata CTX Configuration

CTX100 Cabinet Slots

Music-on-hold/Background Music Interface

A 600-ohm RCA jack and volume controls are built into the processor to interface with Music-on- hold and/or Background Music (BGM) sources (one of the jacks is for future use). With the CTX100, you can have up to 15 MOH/BGM source interfaces by adding:

Up to two BIOU PCBs, each provides three MOH/BGM input sources

An RSTU PCB that provides up to eight MOH/BGM input sources

An ASTU PCB provides one alternate BGM source

SmartMedia Memory

Each processor has an on-board SmartMediaTM memory card slot. A SmartMedia flash memory card can be inserted into the slot to backup and restore customer program data. It also makes it easy to upload operating system data for software upgrades and is used for maintenance functions.

CTX100 Processor Optional Subassemblies

Optional subassemblies can be attached to the ACTU2A-S or ACTU2A processors to provide additional features. The subassemblies are:

AMDS (Modem) – Provides a 33.6Kbps/V.34 modem for point-to-point local or remote connection to the CTX WinAdminTM administration PC.

BSIS (Serial Port Interface) – Provides up to two RS-232 interface ports for SMDR interface to Call Accounting devices, SMDI or Toshiba Proprietary interface to Voice Mail devices, and two future applications.

CTX100 Cabinet Slots

Base Cabinet

Strata CTX Configuration

The Base Cabinet has one dedicated slot used for the system processor PCB and four universal slots (S101~S104), that can accommodate station, line or option PCBs. It also houses a power supply that is packaged with the cabinet.

Expansion Cabinets

One expansion cabinet provides four universal PCB slots (S105~S108) that can accommodate station, line or option PCBs. It also houses a power supply that is packaged with the cabinet.

Strata CTX I&M 06/04

2-3

Image 49
Contents Digital Solutions Division Radio Frequency Interference FCC RequirementsImportant Notice Music-On-Hold Publication InformationToshiba America Information SYSTEMS, INC. Tais Toshiba America Information Systems, Inc Contents Strata CTX Configuration Iii Strata CTX100-S/CTX100 InstallationRack Mount Cabinets PCB Installation Isdn Interfaces Vii IP Telephony and Qsig Over IP MDF PCB Wiring 11-14 Peripheral Installation Xii Xiii IntroductionAdvises you that hardware, software applications, or data IndexProgramming Manual General DescriptionUser Guides Quick Reference GuidesXvi Inspection CTX28 InstallationPackaging and Storage CTX28 FCC/ACTA Registration NumbersSite Requirements Input PowerClearance and Location Power Environmental SpecificationsPower Converter Standard Telephone Ring Circuit Gmau and GstuCTX28 Cabinet AC Power and Grounding RequirementsTB2 AC Voltage 90VAC ± 264VAC AC Current Amps maxTo perform the earth ground test procedure AC Power Ground TestGmau Mount the Cabinet on the Wall Installing the CTX28 CabinetTo mount the Base KSU Cover Screws Side CoverCTX28 Base KSU Interior Overview Instructions PCB InstallationPCB Descriptions CTX28 CHSU28 Cabinet circuit cards Part Title DescriptionGcdu CO, CLID, DKT Set Jumpers on the GMAU1A Motherboard CTX28 Installation Jumper Admin PC Real Time Debug Monitor Install the GVMU1A Voice Mail PCB optionalBusy/Idle On = Busy OFF = Idle To install the GCTU1A into the CTX28 Install the GCTU1A ProcessorGctu Control/Indicator Type of Component Description ConnectorTo install the GCDU1A Install the GCDU1A DKT and Loop Start InterfaceGCDU1A Controls, Indicators and Connectors GCDU1A PCBInstall the GETS1A Install the GSTU1ATo install the GETS1A CD1 LEDInstall the HPFB-6 Reserve Power Battery/Charger Install the BSIS1A optional12 CTX28 Reserve Power Duration Estimates Hardware HPFB-614 HPFB-6 Reserve Power Installation Install WiringRS-232C Base TX Music On Hold MOH P10 to Hpfb Battery Cord TB1 to Hpfb FGDigital Telephone Connection 16 AC Adapter Wiring ProcedureBattery Backup Feet Meters CTX28 KSU or Maximum line length 24 AWG Mode PairLoop Limits 13 Digital Telephone/DIU/DDSS Console/ADM/Loop LimitsCTX28 Secondary Protection InstallationCTX28 14 Station Wiring for Amphenol Connector P1 on GMAU1 MDF WiringPin No Signal Station Strata CTX28 Gvmu Administration PC ConnectionsPPTC25-MDM PPTC-9Strata CTX100-S/CTX100 Overview Strata CTX ConfigurationCTX100-S and CTX100 Processors CTX100 Cabinet Slots Licensed Software Options CTX100-S/CTX100 License ControlCTX670 Processor PCBs Strata CTX670 OverviewHardware described in this chapter. See Network Interface Large-scale Integrated LSI circuitsCTX670 Processor PCB Subassemblies CTX670 License ControlStrata CTX670 Base Cabinet Interior CTX670 Cabinet SlotsSystem Capacities CTX670 Remote Expansion CabinetCabinet and Slot Capacities Station/Peripherals System CapacitiesBase & Expansion Line Capacities and Universal PCB SlotsLines Station Buttons per System Station ButtonsFeatures System Feature CapacitiesMute External BGM Control Relay4 Zone Relays4 CTX100 Base CTX670 CTX670 Expanded FeaturesStation, Line and Option PCBs Universal Slot PCBsStation PCBs Digital/Standard Telephone Interface Unit Rdsu Digital Telephone Interface Unit BWDKU1AInterface Options Volt Supply Internal Option R48SCO Line PCBs Strata Net Over VoIP Interface Unit BIPU-Q1A Caller ID Interface Subassembly RcisInternet Protocol IP Interface Unit Bvpu Interface Options LAN, Internet, WANIsdn Primary Rate Interface Unit BPTU1 or RPTU2 CO Line PCBs Isdn U-type Basic Rate Interface Unit RbuuLoop Start CO Line Interface Unit Rcou T1/DS-1 Interface Unit RDTU2CTX100 System Processor and Option Interface PCBs Functional Block DiagramsBPSU672 Cabinet CTX100 and CTX670 CO Line Side Functional Block Diagram CTX100 and CTX670 Station Side Functional Block Diagram Worksheet Description CTX670 Remote Cabinet Configuration ConsiderationsComponent Worksheets Main Location Remote Location 1 2 3 4 5 Worksheet 1 Toshiba DKT and IP TelephonesIP Telephone Qty Main Location Remote Location 1 2 3 45 Worksheet 2 Standard Telephone, Stratagy DK, IVP8Miscellaneous Digital Telephone Equipment See Table Miscellaneous Standard Telephone SLT Equipment RequiredPCB Worksheet 3 CO LinePCB Name Slots Required Qty Miscellaneous CO Line EquipmentWorksheet 5 Strata CTX100 Cabinet Slots Worksheet 4 Page/MOH/Control RelayActu Worksheet 5 Strata CTX100 Cabinet Slots Bdku Adku CTX100 Max. Capacity Configuration ExamplesBdks Bdku Rcou Bdks Rcos Bdku Rcou RCIU/RCIS Bdks RcosBdku Rcou Bdks RcosRCIU/RCIS Adku Bdku Rcou AdkuClid Rcou RCIU/RCIS 34 CTX100 Base 16 stations and 48 T1 and/or PRI lines CTX100 Base 40 stations and 24 T1 and/or PRI linesS102 S103 S104 RDTU2 Bdku Bdks Bdku BdksRDTU2 Adku Bdks Line Ground Start only CTX100 Analog Tie, did and/or Ground Start Lines Strata CTX ConfigurationStrata CTX Configuration Worksheet 6 Strata CTX670 Cabinet Slots 52 Main Processor PCB/ Remote Cabinet Configuration PCB Placement GuidelinesRrcu PCBs Remote Cabinet Configuration Rrcu PCBs Needed at Processor PCBs54 Rdtu PCB Cabinet Slot Configuration 53 Remote Cabinet Data Cables and ConnectorsBiou Interface PCB T1 Digital Line PCBsIsdn PRI Digital Line PCBs 55 Bptu or Rptu PCB Cabinet Slot ConfigurationPRI Lines Slots Bptu or Rptu Bptu or Rptu cabinet slot Isdn BRI Digital Station PCBs Power FactorAnalog and VoIP Tie Line PCBs Isdn BRI Digital Line PCBs+5VDC PF Worksheet 7 System Power Factor Check+5VDC PF 24VDC PF 58 PCB and Power Supply Power Factors PCB TypeTotal Power Factor PF Telephone/Device Power FactorsMain Location Remote Location 4 5 CTX100 Cabinet Power Factor CheckCTX670 Cabinet 1 base Slot CTX670Total Cabinet PF CTX670 Cabinet Slot 24VDC PFCTX100 AC Power Considerations Worksheet 8 CTX Primary AC and Reserve PowerCTX670 AC Power Considerations 59 Strata CTX100 Electrical Characteristics62 CTX100 Typical Reserve Power Duration Estimates Reserve Power CTX100 and CTX670CTX670 Cabinet Power Enter the Number Components Required Number of CabinetsAPSU112 Primary/Reserve Power Cabinet HardwareABTC-3M AbcsRPSB2 BPSU672BPSB240 BACL240Bbdb Local Electrical Cabinet Cabinets Local Electrical Code Cabinet CabinetsLocal Cabinet AC Power Component InstallationCabinet Cabinets Local CabinetPart Number Strata CTX Comments Qty Software Licenses Worksheet 9 Software Licenses71 Hardware Compatibility Hardware CompatibilityPower Supply Unit Admin ModemBattery Distribution Power StripCTX100 Installation Strata CTX100-S Strata CTX100-S/CTX100 InstallationCabinet Size and Weight Side View Environmental Considerations Power ConsiderationsBTU Rating Base plus Expansion Cabinet Alternate or Additional Ground AC Power and Third-wire Ground TestRemove Cabinet Covers Installing the CTX100 CabinetRemove the Back Cover from the Cabinets Cabinet CoverMount the Base Cabinet Check the Base/Expansion Power Supply Jumper PlugBase Mount the Expansion Cabinet if required Base and Expansion Cabinet Interior Install Reserve PowerInstall the Optional ABCS1A Battery Charger Reserve Battery ConsiderationsInstall the Battery Cable Batteries/1-Cabinet Batteries/2-Cabinets 10 Cable Wiring for the Base and Expansion Cabinets Top view 12 Cable Wiring for the Base with an Expansion Cabinet Check the AC Power Fuses Check Power Supply Circuit Breakers and FusesCheck the -24 Volt Circuit Breakers 14 Power Supply Connectors Top View Check the Power Factor Indicator and Reset Button15 Power Supply APSU112 Remove and Replace the Power Supply if requiredReplacing the Power Supply To install the ACTU2A Set Jumpers and Install Option PCBs onto the Actu18 Actu PCB CTX100 Processor To Install ACTU1AInstall the Main Processor Actu PCB Provides Comments Installs On Install Other PCBs into the CabinetsCTX100 Cabinet and Processor Components ActuBsis Attach and Route PCB CablesSMDR, Smdi Abcs22 Avoid Improper Cable Routing Strata CTX670 Strata CTX670 InstallationStrata CTX670 Installation CTX670 Minimum Clearance Requirements Installation Strata CTX670Reserve Power Power ConsiderationsLocation of Approval Labels FCC Registration InformationRecommended Installation Sequence Cabinet Installation ConsiderationsStep Reference Information Check the -24 Volt Circuit Breakers Reset Circuit BreakerCircuit Breaker Location and Slot Assignments see Figure Power Supply BPSU672 Removal Check the Power Factor Indicator and Reset ButtonPower Supply Replacement Power Factor PF alarm LED indicates Wall Mounting the Base Top Cabinet Mount CabinetsWall Mounting Expansion Cabinets Cabinet Mounting Surface Diagram Cabinet Cover Removal and Installation Hanger Back Cover Hanger Hole Mounting Strip Marking Hole Trace Upper Arch Back CoverCTX670 Cabinet Interior Base Cabinet B50MT Cable ShieldPair Amphenol Cables Knock Out Plastic Top Pair To MDFAmphenol CablesGround the System 11 Cabinet Grounding AC Power Requirements Install AC Power ComponentsPower Cabinet Hardware Option Description Cabinet AC Power Component DescriptionBBTC2A-2M battery cables supplied with Bbdb Power Supply AC/Reserve Power and Data Cabling OverviewPower Strip Cables BBTC1A-2M Cables To Reserve Power Batteries 2 m13 208VAC/240VAC Power/Data Cabling for up to Seven Cabinets Local Electrical Code Cabinets Cabinet AC Power ConsiderationsLocal Cabinets 14 AC Power Strip Installation 15 AC Power Cords for One to Five Cabinets 16 AC Power Cords in Six or Seven Cabinets RPSB2 or BPSB240 Power Strip Right Side AC Power Cables FrontTo AC Outlet Bonding Connection PlatesTypical Reserve Power Duration Estimate Number of Cabinets Install Reserve PowerReserve Power for One or Two Cabinets Wall Mount Reserve Battery Cabinet Components/CablesBbdb Reserve Power for Three or More Cabinets Wall Mount Batteries/1~7 Cabinets with Bbdb Floor Mounting One or Two Cabinets Cabinet Floor MountingBCCB240 BfifFloor Mounting Three or More Cabinets Anchor Bolts Mounting Screws Anchor Bolts Bfif is inside of cabinet edgeFloor Fixture Bfif Mounting ScrewsDrilled holes Bolt Cabinets to Concrete FloorBolt Cabinets to Computer Room Floor Bolt Cabinets to Wooden FloorStrata CTX670 Installation Three or more BCCB120 Cabinets Bfif Strata Batt Bccb Battery Wire Specifications #10 AWG minimum 2 pairs 42A maxConduit Holes to 1/2 inch trade size From 20A dedicatedStrata CTX670 Installation PCB Option Considerations PCB Installation ConsiderationsHardware Options Software OptionsBCTU1A/BEXU1A Installation P601 Strata CTX670 Installation Bexu P601 Batt RJ45 LANLINK, TX, RX LED P901 BattBEXU1A To adjust the CTX670 MOH/BGM source BECU/BBCU Installation31 Bbcu Processor PCB 33 Installing Bexs onto Becu Base Cabinet see Figure Control/Indicator/Connector Type of Component Description 12 Bbcu Controls, Indicators, and Interface ConnectorsBexs Batt38 Remote Expansion Cabinet Connection Remote Expansion Cabinet Unit39 Remove/Replace Remote Cabinet Cover Remote Cabinet Installation InstructionsClose the data cable doors RRCU1A Specification 42 ROMS1A Subassembly 15 Fiber Optic SpecificationBIT Status IndicatorsLED Monitor Port Pin Assignments Monitor Port Communication ParametersStrata CTX670 Installation Basic Specifications Ventilation SpaceLocation Environmental ConditionsRack Mount Cabinets Model BRPSU672AE135386 Move Flange Position Optional Assemble RackTake Off Base of Cabinet Take Off Front and Back CoversAttach Cabinet to Rack Rack Hole Positions Reattach Cabinet to Base Install and Attach Cabinets to RackAttach Amphenol Cable Attach the AC Cable Connect Data and Ground Cables Verify Power Supply Settings Install Power Strip BRPSB120A Optional Install Reserve Power BBDB1A PBTC1A-3MInstall Reserve Power for Three or More Cabinets Install Reserve Power for One or Two CabinetsRack Mount Install Reserve Power Battery Distribution Box if requiredAttach Front and Back Covers Rack Mount Cabinet Grounding Bottom Up Configuration Center back wiring Wiring for 7 Cabinet ConfigurationTop Down Configuration Back View Front View Side View Top Down Configuration Left Front wiring BRPSB120A Primary Power Cabinet HardwareBRPSB240A BACL240AFront View Front View Back View AC Power Component Requirements Cabinet AC Power ConsiderationsDC Voltage Connector Plug Pin Wires Yellow Blue White Green Power Supply Unit BRPSU672ARed Circuit Breaker Location and Slot Assignments Remove Nema 6-20P from Power Strip Changing Plug for Power Strip BRPSB240AAttach Nema L6-20P Plug to Power Strip Rack Mount Cabinets 14 AC Cabling One to Five Cabinets AC Cabling15 AC Cabling Six to Seven Cabinets Rrcu Remote Cabinet Data Cables and Connectors PCB Chapter Layout PCB InstallationPCB Hardware/Software Options PCB Installation Power Supply ConsiderationsCTX100 Actu Processor PCBs CTX670 BCTU/BEXU Processor PCBsAdku Digital Telephone Interface Unit Adku InstallationAdku Hardware Options ASTU1 Wiring Astu InstallationAstu Standard Telephone Interface Unit CTX100 only SW2 Astu Electrical Characteristics DescriptionFG1 Wire from Astu P2 plugs into Actu P8 To install the Bdks Bdku InstallationBDKU/BDKS Digital Telephone Interface Unit Bdku Hardware OptionsBDKU/BDKS PCB Bdku Controls, Indicators, and Interface ConnectorsBiou Option Interface Units Biou InstallationN.O MOH1, MOH2, MOH3BSTU/RSTU Installation R48S -48 Volt Supply Subassembly InstallationBSTU/RSTU Standard Telephone Interface Unit Bstu Controls and Interface Connectors RSTU1, 2 and 3 Controls, Indicators, and ConnectorsRSTU3 Controls and Interface Connectors PCB Installation Rstu or RSTU2 Controls and Interface Connectors Bvpu Installation Bvpu ConfigurationBvpu Internet Protocol IP Interface Unit 11 Bvpu PCB SW0BWDKU1A Digital Telephone Interface Unit BWDKU1A InstallationBWDKU1A BDKU/BDKS BWDKU1A and BDKU/BDKS ComparisonPDKU2 Digital Telephone Interface Unit PDKU2 InstallationPDKU2 Hardware Options RCIU1 or RCIU2 Installation RCIU1/RCIS or RCIU2/RCIS InstallationRCIU1, RCIU2, Rcis Caller ID Interface 14 RCIU1/RCIS PCB To install an RCOS3A PCB Rcos Installation Internal OptionLights to indicate that line circuit is in operation 16 RCOS3A PCB To install an RCOU3A or RCOU1A PCB Rcou Installation18 RCOU3A PCB 20 PCOU2 PCB Rddu Direct Inward Dialing Line Interface Unit Rddu InstallationRddu Installing Rsts Internal Option Installing R48S Ring Generator Internal OptionRdsu Installation To install the R48S on the Rdsu22 RDSU, Rsts PCBs PCB Installation Pemu Installation REMU2A and Remu InstallationRDTU2 T1 Interface Unit REMU2A Tie Line UnitREMU2A Tie Line Unit 24 Remu PCB 25 Pemu PCB PCB Installation To install an RGLU2 PCB RGLU2 InstallationRGLU2 Loop/Ground Start CO Line Interface Unit PCB Installation RMCU/RCMS E911 Cama Trunk Direct Interface Rcms Subassemblies Installation28 Rcms Subassembly stand-alone Rmcu Installation29 Rmcu Interface Card 20 LED Indications Normal Operation Status Rcms LEDsNB LED CB LED Network Busy Customer Busy21 PCB Network Requirements Network RequirementsPCB/Interface Facility Interface Code Network Jack Ringer BRI S/T Overview PRI OverviewBRI U Overview Isdn InterfacesIsdn Reference Model Strata CTX Isdn Reference ModelCSU Requirements BPTU/RPTU OverviewSlot Assignments Power Factor Bptu InstallationTo install an Bptu PCB Bptu Interface UnitBPTU1A Bptu Self Test Bptu Cable Length Equalizer SwitchesSW4 SW5 SW6 Bptu Loop Back Jumper Plugs Bptu Front Panel IndicatorsFerrite Core Bptu CablingTo install an Rptu PCB Rptu InstallationRptu Switches, Jumpers, and Connectors Switches/Jumpers/Connector DescriptionInterfaces IsdnRptu LED Functions Rptu SW1 Cable Length SettingsFunctions SW1Cable Length Bptu and Rptu CablingFifteen feet of CAT5 unshielded cable Cable InstallationFerrite Core Ferrite Core InstallationOverview RBSU/RBSS Interface UnitsRbsu Connection Options RBSU/RBSS Interfaces between the S/T Reference Points Capacity and Cabinet Slot InformationRBSU/RBSS Installation PS-1 Backup Power OptionSet Option Switches/Jumpers Run Related ProgramsCircuit Option Type Circuit Type Description Switch RBSU/RBSS Option Switches, Jumpers, and ConnectorsInstall the Rbss Install the RebsInstall the R40S Install RBSU/RBSS PCBs into Cabinet Modular Jack Pin ConfigurationsBRI S/T Circuit Jack TE or NT Mode CKT1 CKT3 Monitor JackPower Failure Terminal Screws RBSU/RBSS Premise Wiring GuidelinesBRI Wire Type Recommendations RBSU/RBSS BRI Cable Jacks and ConnectorsTX+ RX+Strata CTX BRI Circuit EMC Ferrite Core Requirement Connecting Rbsu to Network Side TE-Mode17 Rbsu to NT1 Point-to-point Connection Connecting RBSU/RBSS Station Devices NT-Mode18 RBSU/RBSS NT Circuit Pinout on Passive Bus 19 Simplified Short-branched Passive Bus RBSU/RBSS Passive Bus ConfigurationsTo install the subassemblies Rbus Rbuu InstallationTo install an Rbuu PCB RBUU/RBUS Interface Unit23 Rbuu PCB PSI1 Definition LED Off LED On LED BlinkingLine-side cabling RBUU/RBUS Wiring GuidelinesRJ45 Jack RJ45 Demarc Jack Isdn Interfaces RJ11 Demarc JackCall Monitor Jack Cabling Station-Side CablingBRI-U, LT Interface Terminal Loop Back Test Isdn Testing and TroubleshootingStrata System 30 Loop-back Test Loop-back TestLoop-back Test Timing and Synchronization31 Primary and Secondary References Call Monitor Output for Isdn PRI/BRI Call Monitoring33 PRI Start-up and Synchronization Sequences 34 PRI Outgoing Call Connect and Release BRI Call Monitor 35 Outgoing Call Setup Output of BRI Call Monitor36 Incoming Call Setup Output of BRI Call Monitor Isdn Interfaces Select Slot Assignments Program ChannelsRDTU3 PCB RDTU3 T1 Interface UnitRDTU3 LED Functions RDTU3 LEDs Indication To install an Rdtu PCB Rdtu InstallationRDTU3 to Network RDTU3 CablingRdtu to PBX T1 Direct Back-to-back Connection up to 655 ft RDTU3 to PBX T1 Separated More Than 655 ftNetwork Jack/RDTU3 Modular Jack Pin Function Connecting two RDTU3 PCBs RDTU3 Equalizer Switches RDTU3 Self Test and CSU Test SwitchRDTU3 Front Panel Indicators RDTU3 Loop Back Jumper PlugsLoop Back Call Data Monitor JackRDTU3 Status Commands Function Format Indication CommandsRDTU3A Call Data Information ALARMYAON/OFF BAON/OFF FSLON/OFF IndicatorsRDTU3 Indications Timing Type DT DHin Data Code Data Hex Meaning DT DHin Data Code Data Hex Meaning 10 DR DHout Data Code Data Hex Meaning RDTU1 & 2 Installation SW1 Equalizer Switch and Loop Back Jumpers Internal OptionRDTU1 & 2 T1 Interface Unit CTXRDTU1A Falm 12 RDTU1 and 2 LED Functions Alarm LEDMfalm YalmRdtu Cable Connections RDTU1 and 2 Cable InstallationLoop Back Testing CSU InstallationRdtu Self Test Network/CSU/RDTU Span Test Network/CSU T1 Span TestTest Rdtu Lines Loop Back Testing IP Telephony and Qsig Over IP Pre-installation GuidelinesClient Firewall Considerations Dos and Don’ts for Setting Up the SystemMethods of Estimating Bandwidth Requirements Perform a LAN Voice Readiness AssessmentCTX Prgs Review Voice Quality ConsiderationsAbove and the Codec parameters 711 at 20msConnect BIPU-M2A to LAN or VPN Server Install BIPU-M2ABIPU-M2A Interface Unit Indicator DefinitionBIPU-M2A or BIPU-Q1A Buttons, LEDs and Jumpers Install IP Telephones Over IP IP Telephony IPT Operation NotesQsig IPT Telephone Options Tilt Stand InstallationIP Telephone Add-on Modules External Speaker Unit Hesb OptionStation Option Interface PCB Compatibility Handset/Headset Option StrapsStrap on IPT PCB Explanation Handset Hanger To wall mount IP telephonesIPT Connections Connect IPTs to NetworkIPT Anywhere IP Telephony and Qsig Over IP IP-CTX Virtual Private Network Connections Example Security RequirementsAddressing Power over LANOUT CAT5OUT CAT5 IPTInstalling and Operating the SoftIPT Before You Begin Hardware/Software RequiredInstall SoftIPT Start the SoftIPT Upgrading the SoftIPTMaking a Call Switching a Call to Your HeadsetTo make a call Creating a Directory Using the Directory to CallTo change Feature Button Labels Labeling Feature ButtonsUninstalling the SoftIPT Using the Call LogTo access the Call Log To remove SoftIPT from your PCApplication Notes for Wireless 802.11 Networks Considerations Wireless RecommendationsAudio Devices Tested PlatformsPC Platforms IP Telephone Ping Test CTX IP Troubleshooting7Ping Test Action LCD Indication Remarks Ping toCollect CTX Trace Data on CTX SmartMedia Card LCD Network Failure DisplaysCollect Bipu Logs 8LCD Network Failure Conditions LCD Indication RemarksBipu Reset Check Log0.log/Log0.err for Error Message OutputOptional Data for Program Update CTX System ConfigurationVerify CTX/BIPU/IPT Hardware, Software and Firmware Version Mandatory DataNetwork Information Network DiagramNetwork Equipment that BIPU/IPT Directly Connects To CTX100 Slot Base ExpProtocol Name Type Use, Purpose Capture PacketsUsing Repeater Hub Dumb Hub How To Capture PacketsUsing Switching Hub with Mirroring Function Capture PointsUsing PC or Workstation With Multiple Network Interfaces IP Troubleshooting Resolutions10 IP Troubleshooting Problems and Resolutions Problem Action Cause How to ResolveLAN Problems Problem Action Cause How to Resolve IPT Problems Connect Error BIPU-Q1A Strata Net Qsig over IP Interface Unit Private Networking Over Internet ProtocolStrata Net Qsig Over IP and IPT Bandwidth Requirements 12 Qsig over IPClass Definitions Delay ms Jitter msClass KbpsConnect BIPU-Q1A to LAN, Server or Router BIPU-Q1A InstallationMDF 10-1Station Loop Lengths Mode Pair Pair plus10-2 Station Loop Lengths110-3 MDF PCB WiringLoop Limits for DKT3000-series Telephones 10-4 Station Wiring Diagrams10-5 Adku and BDKU/BDKS Digital Station Wiring10-6 Bwdku Digital Station Wiring10-7 Astu WiringPdku Wiring Pdku Digital Station Wiring10-9 Digital Telephone DSS and Ddcb External Power ConnectionMDF PCB Bdku Station MDF Cross Connect Record 10-10KSU Slot Number Adku Bdku Pdku Bdks10-11 Rdsu WiringCKT 10-12Port Directory Device/Standard Telephone Location Number 10-13 Rstu or Pstu Analog Devices WiringPort Intercom Device/Standard Telephone Location Number 10-1410-15 Power Failure Cut Through Dpft Wiring Pin-outs10-16 10-17 RGLU2, Rcou or Pcou Wiring10-18 Wiring RCOU/RCOS Wiring10-19 10-20 RMCU/RMCS Wiring Diagram10-21 RCIU1/RCIS or RCIU2/RCIS Wiring10-22 Did and Tie Line WiringLead PIN # 10-234WR1 2 4WT1 Line #4 Line #3 Line #210-24 Pemu Wiring10-25 17 MDF Wiring/4-Wire Tie Line to Pemu10-26 Option Interface PCB Wiring Diagram11-1 Series Digital Telephones TelephoneStation Apparatus Digital Telephone System Connection Series Telephone Installation11-2 Subassembly No. per Function Phone 3000 Telephone Subassembly UpgradesSeries Telephone Option PCBs 11-3Bpci Bheu Bvsu ADM Hheu BHEU/HHEU 11-4DKT3000 and DKT2000 Component Compatibility Series DKT CTIBvsu Upgrade Installation for DKT3000-series Telephones Telephone Speaker Off-hook Call Announce Upgrade Bvsu11-5 Removing Telephone Base Bvsu InstallationBheu Installation Telephone Headset Bheu Upgrade11-7 11-8 Bheu InstallationTelephone Option Straps Connector Locations11-9 DKT3020-SD11-10 DKT3001 Bheu Connector Location11-11 Bpci Installation11-12 Install Tapi Service ProviderTest/Use Tapi Service Provider Add/Edit TSP Configuration InformationIPT Telephone 11-1311-14 Series, IPT1020-SD Button Layouts13 DKT3014-SDL Buttons 11-1514 DKT3001 Buttons 11-16Series/IPT Telephones Telephone Settings11-17 Reset LCD Contrast for the DKT3014-SDL Speakerphone/Microphone Sensitivity Adjustment11-18 Turn DKT2000 Mode On/Off DKT2000 Mode On/OffMsg/Feature Button Activation/Deactivation DKT3001 only Series TelephonesCountry Code Settings for Mu Law/A Law Country Settings On/Off11-20 Test the Display on Large LCD Telephones DKT3014-SDL onlyTo install DADMs Digital Add-on Module Installation11-21 Dadm Comparison Add-on Module DADM3020 DADM312015 Digital Add-On-Module 11-2211-23 Tilt Stands11-24 Tilt Stand Installation with Add-on Modules11-25 21 Release Adjustment Button Station Apparatus11-26 Tilt Stand for DKT/IPT + Two ADMs11-27 Telephone Wall MountingTo mount digital telephones To wall mount DKT3001 or DKT2001 digital SLTs 11-28Standard Telephones Direct Station Selection DSS Console/System ConnectionDSS Console Connections 11-2911-30 Cordless Digital TelephonesCordless Telephone Compatibility Bdks D2Review Safety Instructions Cordless Telephone Installation11-31 11-32 Place DKT3000-series Telephones into 2000-Mode Select Location11-33 To change DKT3000-series telephones into 2000-mode11-34 Connect Telephone CablesTo connect as a stand-alone telephone To connect to a Strata DKT11-35 Connect and Apply PowerBase Unit Charging Unit11-36 Wall Installation OptionalStandard Wall Plate Mounting Direct Wall Mounting 11-37To wall mount the base unit Charging Unit Wall Mounting 11-38Raise the Base Unit Antenna Install Handset Battery PackCharge Batteries for First Time 11-39Attach Belt Clip Optional Install Headset Optional11-40 To remove the belt clipTroubleshooting Cordless Telephone Troubleshooting and SpecificationsTroubleshooting Suggestions Condition 11-41Cleaning Charging Unit Contacts Low Battery11-42 DKT2204-CT Charging Unit picturedSimultaneous Conversation Channels Charging Spare Battery Packs DKT2204-CT onlyDKT2204-CT DKT2304-CTRange and Performance Telephone Line ProblemsRadio Interference PrivacySpecifications Feature DKT2204-CT DKT2304-CT General Specifications11-45 Base Unit2000 Telephone Subassembly Upgrades No. per Function Phone Telephone Speaker Off-hook Call Announce Upgrade DVSU/ BvsuSeries Telephones Series Telephone Option PCBs31 BVSU/DVSU Installation Station Apparatus 30 Speaker Off-hook Call Announce Upgrade BVSU1A11-48 Hheu InstallationFeed Through To Hesb For HESC-65A Cable Block SW601 HESC-65 Cable HESC-65A Cable11-49 Locations DKT2020-SD Strap and ConnectorBeep Strap Carbon Headset/Handset Straps11-50 11-51 External Power Straps10 DKT International DIP Switch Settings DIP Switches11-52 11-53 DIP Switches11-54 11 DKT2020-FDSP DIP Switch SettingsTo use the External Microphone 37 Rfdm Plug on DKT2020-FDSP 11-5511-56 Speech Training ModeSpecial Button Operation Button DKT 2001 Installation To toggle full/half-duplex modeDigital Single Line Telephone DKT2001 only 11-5711-58 Application PC and Server Interfaces Peripheral Installation12-1 12-2 Network Interface ConnectionsNetwork Jack LED Indications 12-3 Network Interface Connections Peripheral InstallationApplication PC or Server Direct Connection 12-412-5 TIA Network Wall Jack Wire Color CodesCTX Modem Programs and Dialing Numbers 12-6PPTC-25F 12-7Pptc DTE12-8 Music-On-Hold/Background Music InterfacesMOH/BGM Interface Connection 12-912-10 External Page with Biou InterfaceBiou 1 or 12-1112 Zone Page with Multiple Amplifiers 12-1212-13 Control Relays with Biou InterfaceDdcb and Mdfb Cabling Door Phone Wire ConnectionsDdcb Wall Mounting 12-14Calling a Door Phone Calling from a Door PhoneDoor Lock Control Door Phone/Lock Programming12-16 16 DDCB3 Wiring and Ddcu Door Lock PCBTo Turn the Loud Ringing Bell Feature On/Off Default is Off Set Up the Telephone for the External Ringer OptionExternal Speaker Unit Hesb Options Telephone External RingerModular connector SW601 HESC-65 Cable HESC-65A Cable HESC-65A and Bheu InstallationTelephone Bheu to External Speaker Hesb Cable Connection 12-1812-19 Strap and Connector Locations InstallationPeripheral 12-20 21 Wiring the Telephone External Ringer with Hesb InterfaceAmplified Page Speaker Option To install the Hesb amplified speaker option12-21 Test the Telephone External Ringer OptionTo test the amplified speaker option 12-22Talkback Amplified Page Speaker with Talkback Option To install the Hesb amplified page speaker with talkback12-23 To test the talkback amplified speaker12-24 Hesb Wall MountingTo wall mount the Hesb One Wall Mounting HolePower Failure Transfer Unit Power Failure Options12-25 12-26 Power Failure Emergency Transfer Dpft InstallationTo test the operation of the Dpft Smdr Record Types Station Message Detail Recording Smdr12-27 Call Record TypesSmdr Record Format Line Column Name 12-28Sample Call Record Explanation Rel .02 or lower Field 12-29Record Formats Release 12-30Smdr Record Format Software Release Line Column Name Sample Call Record Explanation Software Release R1.03 Field 12-3112-32 Index IN-1IN-2 Dtmf IN-3IN-4 IN-5 QSIG, 2-10,2-17,2-56,7-9IN-6 RSTU/PSTU/RSTU2 IN-7