LG Electronics LKA-200 manual Call Alerting Characteristics, Reliability Test

Page 6

Issue 1 Jan 2006 LKA-200

_________________________________________________________________________________________________

6.4 DC CHARACTERISTICS

6.4.1 on-hook AC impedance

Required result:

f < 200 Hz : More than 25 kohm

697 < f < 1,633

Hz :

More than

80 kohm

f > 3,200

Hz :

More than

60 kohm

6.4.2 off-hook AC impedance

Required result: 400 ~ 1,400 ohm

6.4.3 Return Loss

Required result: More than 10 dB through frequency range 200 ~ 3,200 Hz

6.5 CALL ALERTING CHARACTERISTICS

6.5.1 Minimum Ring Start Voltage

Required result: 20 ~ 40 Vrms at 20 Hz (typical 27 Vrms)

6.5.2 Ring sound level

Required result: (at distance 50 cm for ring signal 20 Hz 70 Vrms) Maximum level : more than 70 dBspl.

6.5.3 Message Waiting Indicator

Required result: Minimum level 70 Vdc for MWI operation.

6.6 RELIABILITY TEST

6.6.1 Temperature test

Required result:

No operation error occurs during each condition;

1)Setup chamber in 00C for 12 hours

2)Setup chamber in 400C at R.H. 85% for 12 hours

_____________________________________________________________________________

6

Image 6
Contents Product Specification LKA-200 Single Line Telephone DistributionFeature Listing Revision History Date DescriptionGeneral Description Programming Procedure Hardware RequirementsElectrical Characteristics Transmission Characteristics Tolr Rolr SolrDC Characteristics Call Alerting Characteristics Reliability Test