Konftel 200NI manual Technical data, Central Unit

Page 25

 

 

Technical data

Central Unit

 

 

 

 

Power supply:

DC transformer 240 V AC/12 V DC; 700 mA.

Network interface:

Analogue POTS, RJ-11.

 

Digital ISDN/S0, RJ-45.

Power supply and

 

 

POTS network cable:

7.5 metre, RJ-11 (line), EIAJ Class IV (power).

Power supply and ISDN

7.5 metre, RJ-45 (ISDN), EIAJ Class IV (power).

network cable:

 

 

Recommended room

Reverberation time: <0.5 sec.

conditions:

Background noise: <45 dB(A).

Frequency response:

200 – 3700 Hz.

Loudspeaker volume:

85 dB SPL (increased if extra microphones are used).

Room echo suppression:

208 ms.

Line echo suppression:

25 ms.

Automatic calibration:

<1 ms impulse (not discernible).

Tape recorder output:

3.5 mm tele jack. Contact for connection of

 

tape recorder may only be connected to a SELV

 

voltage in accordance with SS-EN 60 950.

Dimensions:

Diameter 232 mm.

Weight:

800 g.

Temperature range:

5 – 40° C in operation.

Humidity:

20 % – 80 % non-condensing.

EMC:

EN 50 081-1:1992.

 

EN 50 082-1:1992.

 

EN 61 000-4-2:1995.

Electrical safety:

EN 60950.

Telecom approval POTS:

EUROPEAN TBR21.

Telecom approval ISDN:

EUROPEAN TBR3.

Keyboard:

19 keys.

Compatibility:

Konftel 200NI can be connected to any PBX equipped

 

with ISDN/S0 or POTS extension, for example

 

Ericsson: MD110, Fenix. Siemens: Hicom. Nortel:

 

Meridan. Philips: Sopho. Alcatel: 4200, 4400.

 

Ascom: Ascotel. Tenovis: Intergral 3, 33.

25

English

Konftel 200NI • User Guide

Image 25 Contents
User guide Conference phone Konftel 200NI English Contents Arrangements Bottom TopDigital ISDN/S0 Connection Analogue PotsManual network selection default Auto Settings Network set-up after power on default AutoVideo line sharing Connection Own MSN-number default none Tuning Volume controlMute function Calling Incoming callsOutgoing calls Three-party calls If your call is not answeredCalling13 If the R key does not work Pots Programming the R key default setting =Redial Speed dialling, redial Retrieve speed dial numbersMenu Add a new number in Phonebook Edit Select Edit Menu Edit PhonebookMenu17 Delete Name and Number Adjust the Ring Signal VolumeSelect Language 18Menu Change Time and DateKeypad tone Off Menu19 Keypad Tone default onAccessories Remote control Accessories Remote control functions Accessories Extra microphones Spare parts Accessories and spare partsMaintenance TroubleshootingCentral Unit Technical dataRemote control accessories Technical data Extra microphones accessoriesDisplay and keyset