Flow Chart of Troubleshooting
9-16. DCS Transmitter
TX ON (5Level)
Yes
①
MODULE100 Pin13≥
No
MODULE100 pin8
≥ 25dBm
Yes
Yes
Resolder
MODULE100,C102,L102
Check MODULE100 | No |
| |
pin11 = L (2.6V), |
|
Pin9 = H |
|
Check ANT Switch control circuit
No
Yes
③
②
Change or Resolder
MODULE100
PAM100 pin17
≥ 25dBm
No
PAM100 pin1
≥
No
U100 pin
C2,B1,B2,A1
≥ 0.2Vp_p
No
Check UCP200
END
Yes
Yes
Yes
Resolder or Change L113,C109,
C110
④
Check PAM100 pin | Yes |
|
| |||||
|
|
| ||||||
2,3,5,6,8, +Vbatt |
|
|
|
|
| Resolder or Change PAM100 | ||
pin4OK? |
|
|
|
|
| |||
|
|
|
|
|
|
| ||
| No |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| Check VBAT or PAM |
| |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| control signal |
|
|
|
|
|
|
|
|
|
|
U100 pin G4,F3,D6, |
|
|
| ⑤ |
No |
| |||
C5,B3,A5,F1 | Check & Resolder | |||
29,32,33,36 ≥2.8V |
|
|
| |
|
|
| C115,C116,C117,C114 And | |
|
|
| ||
pin C1 ≥2.9V |
|
|
| |
|
|
| PMU Part | |
|
|
|
| |
|
|
|
|
|
⑥
Yes
Resolder U100
SAMSUNG Proprietary-Contents may change without notice