Installation Instructions

Sheet 2 of 3

Warning: Before starting any work ensure that all sources of power are turned off. All work must meet local/national codes and be performed by a certified electrician. Do not mount fixtures vertically.

Roundel, XL

INDOOR

PS (Pendant Swivel)

Visor and Non-Visor

3.Mounting Fixture to Pendants

1/4-20 x1" Aiming Screw (x2)

Fixture wire

3/8-16 x1" End Screw (x2)

1.After hanging both pendants, carefully lift fixture head into place.

2.Secure fixture using both 3/8 -16 x 1" End screws.

3.Secure desired angle using 1/4-20 x 1" Aiming screws.

4.

Wiring the Fixture

Canopy

Fixture wire

1.After securing the fixture head to the pendants, run fixture wire up pendant tube to J-box.

2.Attach appropriate wires ensuring all connections are properly matched.

3.Secure canopy to mounting plate.

5.

Securing Safety Wires and Aiming the Fixture

#8-32 x.75"

J-box hidden

End Screw

for clarity

(x2)

 

1/4"-20 safety wire

 

connector

40

(x2)

 

End Cap

Side view

1.To secure safety wire to fixture, screw 1/4"-20 wire connector to bottom of pendant bracket.

2.Run safety wire up pendant tube and secure to structure in ceiling.

3.To adjust angle of fixture head, loosen both 1/4-20 x1" aiming screws.

4.Rotate fixture head to desired angle and secure with both 1/4-20 x1" aiming screws.

5.Replace end cap using 8-32 x.75" end screw.

ADY080864 REV B(ECN080377)