NEC XN120 manual Exifu Card and Connections for PCPro

Page 8

Connecting to the System

The following changes must be made in order to connect to the system.

With the telephone system set at default (Program 10-12-01 = IP Address 172.16.0.10 and Program 10-13-01 = 0 [DHCP Server disabled]):

1.The network settings on the PC connecting to the telephone system must be changed. Set the IP address to 172.16.0.11 (172.16.0.12, 172.16.0.13, etc would also be acceptable) and change the subnet mask to 255.255.0.0.

With the telephone set to use the built-in DHCP Server (Program 10-12-01 = IP Address 172.16.0.10 and Program 10-13-

01 = 1 [DHCP Server enabled]):

1.The network settings on the PC connecting to the telephone system must be set to obtain an IP address automatically.

The location of the IP setting depends on the Windows version being used, but for example, with Windows XP you would access these settings by clicking:

START-SETTINGS-NETWORK CONNECTIONS-Right mouse click on LOCAL AREA CONNECTION- Select PROPERTIES-Click on INTERNET PROTOCOL (TCP/IP)-Click PROPERTIES-Select the GENERAL tab if not already selected.

Connecting to the telephone System

In order to use UserPro, the telephone system must be connected to the PC as shown below.

For local connection you can connect via Ethernet either through a hub or with a cross-over cable connected directly to the system, a USB cable or a serial cable.

For remote connection you can connect your PC to an ISDN Terminal Adapter and make a dial up connection to the telephone sytem.

EXIFU Card and Connections for PCPro

Ethernet Connection

You will need the EXIFU-A card installed in the system.

Connect the Ethernet socket of the EXIFU-A card to a NIC card on yout PC. This can be either via LAN or directly via a LAN cross cable.

You will need to setup the NIC in your PC before you can communicate with the system.

2

UserPro Manual

Image 8
Contents XN120 UserProManualTechsupport@necinfrontia.co.uk UserPro Manual UserPro Manual Table of Contents Table of Contents Connecting to the System Exifu Card and Connections for PCPro Connecting to the System Local LAN Ethernet Connection Common Buttons within UserPro Using UserPro Using UserPro UA level Automatic Night Service PatternsUsing UserPro UA level Disa User ID Mail BoxText Message Incoming Ring Group ExtensionNight Mode Switching other group Speed DialDSS key Assignment Doorphone Ringing AssignmentDial-In Name Extension NumbersExtension Settings One Touch Key Assignment Function key assignmentVitual Extension Ring Assignment Using UserPro UA level Trunk Settings ExitUsing UserPro UB level HomeVitual Extension Ring Assignment One Touch Key Assignment Exit Using UserPro UB level Page UserPro Manual