Cooper Lighting 217T8 specifications Photometrics, Ordering Information, Shipping Data

Page 2

2AC 217T8

PHOTOMETRICS

2AC-217 Electronic Ballast

(2)F17T8/TL841 lamps 1400 lumens

Spacing criterion:

(II)1.2 x mounting height, () 1.4 x mounting height Efficiency 84.3%

Test Report: 2AC-217.IES

LER = FL-69 LPW

Yearly Cost of 1000 lumens, 3000 hrs at

.08 KWH = $3.47

Candela

Angle

Along II

45°

Across

 

 

 

 

 

 

 

 

 

 

0

737

737

737

 

 

 

5

735

735

737

 

 

 

10

724

729

735

 

 

 

15

707

719

729

 

 

 

20

682

703

720

 

 

 

25

652

683

707

 

 

 

30

616

658

690

 

 

 

35

574

628

669

 

 

 

40

527

594

643

 

 

 

45

476

555

613

 

 

 

50

422

511

576

 

 

 

55

366

462

533

 

 

 

60

308

408

475

 

 

 

65

248

349

380

 

 

 

70

188

274

266

 

 

 

75

129

181

169

 

 

 

80

76

99

92

 

 

 

85

32

34

33

 

 

 

90

0

0

0

 

 

 

C o effi c i e n t s of Utilization

 

 

 

Effective floor cavity reflectance

 

20%

 

 

 

 

 

 

 

 

 

 

 

rc

 

 

80%

 

 

70%

 

 

50%

 

 

30%

 

 

10%

 

0%

 

 

rw

 

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

 

RCR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

100

100

100

100

98

98

98

98

94

94

94

90

90

90

86

86

86

84

 

1

 

91

87

84

80

89

85

82

79

82

79

76

78

76

74

75

73

72

70

 

2

 

83

76

70

65

80

74

68

64

71

66

62

68

64

61

66

62

59

58

 

3

 

75

66

59

53

73

65

58

53

62

56

52

60

55

51

57

53

50

48

 

4

 

69

58

50

45

67

57

50

44

55

49

44

53

47

43

51

46

42

41

 

5

 

63

52

44

38

61

51

43

38

49

42

37

47

41

37

46

41

37

35

 

6

 

58

46

38

33

56

46

38

33

44

37

33

43

37

32

41

36

32

30

 

7

 

54

42

34

29

52

41

34

29

40

33

29

39

33

28

37

32

28

26

 

8

 

50

38

31

26

48

38

30

26

36

30

25

35

30

25

34

29

25

23

 

9

 

46

35

28

23

45

34

28

23

33

27

23

32

27

23

32

26

23

21

 

10

 

44

32

25

21

42

32

25

21

31

25

21

30

24

21

29

24

21

19

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zonal Lumen Summary

Zone

Lumens

%Lamp

%Fixture

0-30

588

21.0

24.9

0-40

979

35.0

41.5

0-60

1813

64.7

76.8

0-90

2360

84.3

100.0

0-180

2360

84.3

100.0

Luminance Data

 

Average

Average

Average

Angle

0-Deg

45-Deg

90-Deg

in Deg

cd/sm

cd/sm

cd/sm

45

1830

2134

2357

55

1735

2190

2526

65

1595

2245

2444

75

1355

1901

1775

85

998

1060

1029

ORDERING INFORMATION

S A M P L E NUMBER: 2AC - 217- UNV- EB82 - U

Rating

Blank=

Standard

NY=NewYork

Rated

ATW-SW4=

Chicago

Rated

Width

2=2' Width

Series

AC=Accord Series

Number of Lamps

(Not included)

2=2 Lamp

Wattage (Length)

17=17W T8 (24")

Shielding

Blank=Frosted Acrylic SQP=Lens with Square Pattern Insert RDP=Lens with Round Pattern Insert

Voltage(1)

UNV=Universal

Voltage 120-277

Options

GL=Single Element Fuse GM=Double Element Fuse Flex=Flex installed EL=Emergency Installed

Lamps

L8835=T8 Lamp, 17W and 32W, 3500K L8841=T8 Lamp, 17W and 32W, 4100K L8835HL=T8 Lamp, 32W, 3500K, 3100 Lumens L8841HL=T8 Lamp, 32W, 4100K, 3100 Lumens

BallastType

EB8 =T8 Electronic Instant Start.

Total Harmonic Distortion < 10%

No. of Ballast 1 or 2

EB8 /PLUS=T8 Electronic Instant Start.

 

 

 

 

High Ballast Factor >1.13.Total

No. of

Harmonic Distortion < 20%

Ballast

 

1 or 2

 

ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%

No. of Ballast 1 or 2

HPT8 Ballast

Ballast

Packaging

U=Unit Pack PALC=Job Pack, in carton

Type

A=Air (optional)

HB8 L=T8 Electronic Instant Start. Low Ballast Factor .77 HB8 =T8 Electronic Instant Start. Ballast Factor .88

HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2

NOTES: (1) Products also available in non-US voltages and frequencies for international markets.

For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.

HR8 DIM=T8 Electronic Program Start Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Start. Low Ballast Factor .77

HR8 =T8 Electronic Program Start. Ballast Factor .88

HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2

SHIPPING DATA

 

 

 

 

 

 

Catalog No.

Wt.

 

2AC-217

28 lbs.

 

 

 

 

Specifications and Dimensions subject to change without notice.

ADF080358

Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801

08/26/2008 2:35:12 PM

Image 2
Contents Electrical Ballast AccessConstruction FinishShipping Data PhotometricsOrdering Information

217T8 specifications

Cooper Lighting's 217T8 fixture is a popular choice among lighting solutions, known for its efficiency and versatility in commercial and industrial applications. This fixture primarily utilizes T8 linear fluorescent lamps, which are renowned for their energy efficiency and long life, typically lasting up to 30,000 hours.

One of the standout features of the 217T8 is its sleek and unobtrusive design, making it an ideal choice for both new installations and retrofitting existing fixtures. The fixture is available in various configurations, accommodating different lamp lengths and numbers, which allows for a customizable lighting solution tailored to specific needs.

The 217T8 is designed with energy efficiency in mind. By utilizing T8 lamps, it significantly reduces electricity consumption compared to traditional T12 fixtures. This not only lowers operational costs but also contributes to a greener environment, making it an excellent choice for businesses looking to reduce their carbon footprint. Additionally, the fixture can be utilized with advanced electronic ballasts that are designed to further enhance energy savings while providing flicker-free operation.

Another notable characteristic of the 217T8 is its robustness. Constructed from durable materials, the fixture is built to withstand the rigors of commercial and industrial environments. Its acoustical performance is also commendable, minimizing noise in workplaces where a quiet atmosphere is paramount.

Accessibility for maintenance is another key feature of the 217T8. The design allows for easy access to the lamps and ballasts, reducing downtime when replacements are necessary. This user-friendly approach extends the fixture’s usability and ensures minimal disruptions to daily operations.

The 217T8 also offers a range of mounting options that include surface, pendant, and recessed installations. This flexibility in installation allows it to fit seamlessly into a variety of ceiling types and spaces.

In conclusion, the Cooper Lighting 217T8 fixture stands out for its energy efficiency, customizable configurations, robust design, ease of maintenance, and flexible installation options. It serves as a reliable lighting solution that meets the diverse needs of various commercial and industrial applications, making it a smart investment for businesses aiming to enhance their lighting systems.