Power-Up Check
1.Plug in any DC wallpacks that are being used with individual intercom stations. Note: If you plug in DC wallpacks after applying power to the
2.Plug in the AC power cords for any connected
3.If a channel status indicator turns red during operation, locate the short or overload that is causing the problem. Once the short or overload is corrected, the Power Supply should reset itself and the overload indication should go away.
Specifications
General
Input Power Requirements: 100 to 240 VAC, 50/60 Hz
Output Power (each channel): 21±1 VDC, 2 A
Dimensions 1.75”(44.5 mm) high x 8.25” (209.5 mm) wide x 10.31” (261.9 mm) deep Weight: approximately 2.5 lb (1.13 kg)
Environmental Requirements:
Storage:
Operating: 0°C to 50°C, 0% to 95% humidity,
Intercom Channels
General
Connector Type: One
Balanced Mode (set to BAL position)
Line Terminating Impedance: 300 ohms ±10%
Connector
Pin 1 Common (audio and DC return)
Pin 2
Pin 3
Unbalanced Mode (set to UNBAL position)
Line Terminating Impedance: 150 ohms ±5%
Connector
Pin 1 Common (audio and DC return)
Pin 2 +24 VDC output
Pin 3
Speaker Inputs
Type: RCA Phone Jack
Tip: Speaker + Input
Sleeve: Speaker - Input
Approvals
UL, CUL, CE
12