Radio Shack 43-3101 owner manual Using Multiple Intercoms, Using the Doorbell

Page 3

Using the Doorbell

Your visitor presses BELL on the doorbell to sound the doorbell.

Hold down TALK TO DOOR on the indoor intercom to reply to the caller. The TALK TO DOOR indicator lights. When you release TALK TO DOOR, the caller can reply by pressing PRESS TO TALK on the doorbell intercom.

Notes:

If there is no voice communication between the doorbell and the indoor intercom within about 10 seconds, the doorbell intercom may be disabled and should be initialized by pressing BELL again.

You can also use other intercoms to reply to the doorbell as long as they are set on the same frequency.

If the channel is occupied by other intercom users, the door chime cannot be sent to the intercoms in use. The conversation between intercoms will not be sent to the doorbell.

USING MULTIPLE

INTERCOMS

You can set up several indoor intercoms for station-to-station communication. Simply set CHANNEL A/B/C on the back of each intercom to the same frequency as other stations with which you want to communicate.

For example, you could set a station installed in the kitchen to channel A, a station installed in the family room to channel B, and a station installed in a bedroom to channel C. Using the station installed in the kitchen, you can communicate with the station in the family room by setting the channel selector to B, or with the station in the bedroom by setting the channel selector to C. If you set all stations to channel A, you can communicate with the other two stations from any station.

Calling Another Intercom Station

Be sure the intercom stations you plan to use are turned on and adjusted to the desired volume. Press CALL to sound a tone alerting the person at the other station that you are about to speak. The CALL indicator lights.

Hold down TALK and speak in a normal voice. The TALK indicator lights. When you finish speaking, release TALK and listen for a response.

Notes:

Only one party can talk at a time. Wait until the other party finishes before answering.

If your voice sounds distorted, you might be speaking too loudly or too close to the station’s microphone.

WARNING: To reduce the risk of fire or shock hazard, do not expose this product to rain or moisture.

CAUTION

!

RISK OF ELECTRIC SHOCK.

DO NOT OPEN.

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER OR BACK. NO USER-SERVICE- ABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL.

This symbol is intended to alert you to the presence of uninsulated danger- ous voltage within the product’s enclo- sure that might be of sufficient magnitude to constitute a risk of elec- tric shock. Do not open the product’s case.

This symbol is intended to inform you that important operating and mainte- ! nance instructions are included in the

literature accompanying this product.

3

Image 3
Contents Changing the Doorbell’s Tone Installing the Doorbell’s BatteriesSetting the Channel PreparationOperation Using Multiple Intercoms Using the DoorbellCalling Another Intercom Station FCC Statement Care

43-3101 specifications

The Radio Shack 43-3101 is a versatile and reliable multimeter that has found its way into the toolkits of hobbyists, technicians, and professionals alike. Known for its ability to measure voltage, current, resistance, and more, this device offers a blend of simplicity and functionality that appeals to users at all levels of expertise.

One of the standout features of the 43-3101 is its ability to measure both AC and DC voltage. With a maximum voltage range of 600 volts, this multimeter can handle a variety of household and industrial applications. Users can easily toggle between AC and DC modes, ensuring accurate readings whether they are working on electronics, appliances, or complex machinery.

In addition to voltage measurement, the Radio Shack 43-3101 boasts the capability to measure current up to 10 amps, making it a valuable tool for tasks that require monitoring power consumption. The resistance measurement feature is also noteworthy, with the device offering a range that accommodates both low and high resistance values, providing electricians and DIY enthusiasts with the flexibility they need.

The device incorporates a digital display, which enhances readability and allows for precise readings in various lighting conditions. With an analog-to-digital conversion, users can trust that the data presented is both accurate and easy to interpret. The multimeter is equipped with a dial for selecting the desired measurement function, simplifying the user experience.

Durability is another critical aspect of the Radio Shack 43-3101. Constructed with a sturdy casing, it is designed to withstand the rigors of daily use, making it a reliable companion on any job site. Its compact size and lightweight form factor also contribute to its portability, enabling users to carry it with ease.

The Radio Shack 43-3101 is powered by a 9V battery, ensuring extended usage without frequent replacements. It features an auto-off function to conserve battery life when the device is not in use, thus enhancing its practicality.

In summary, the Radio Shack 43-3101 multimeter is characterized by its dual voltage capability, current and resistance measurement, durable construction, and user-friendly features. Its blend of accuracy and ease of use makes it a preferred choice for professionals and hobbyists looking to perform electrical measurements with confidence. Whether for professional use or personal projects, the 43-3101 proves to be an indispensable tool in the realm of electronics.