UNIT DETAILS

Control unit common information

*The information on this page is common to Central control unit (IS-CCU), Add-on control unit (IS-SCU), Room sub control unit (IS- RCU) and IP control unit (IS-IPC).

Accessories

Mounting bracket × 2

Installation manual (a booklet)*1 × 1

Screw (for wall-mounting) × 4

CD-ROM (Installation manual, Setting manual and Operation manual)*2 × 1

Screw (for rack-mounting) × 4

China RoHS paper × 1

Screw (for fixing mounting bracket) × 6

Mounting

*1: IS-CCU only

*2: IS-CCU and IS-IPC only

<When mounting into the 19-inch rack>

1 Attach the mounting brackets to the unit.

Screw hole x 3

Mounting bracket x 2 (included)

Screw (for fixing mounting bracket) x 6 (included)

NOTE:

Screw (for rack-mounting) x 4 (included)

Do not use screws other than the included ones.

<When mounting on a wall>

1 Attach the mounting brackets to the unit.

NOTE:

Do not use screws other than the included ones.

Screw (for fixing mounting bracket) x 6 (included)

Screw (for wall-mounting) x 4 (included)

2 Mount the unit on the wall with the screws for wall-mounting.

19-inch rack (2U)

 

2 Set the unit in the

44.5 mm

19-inch rack and fix

it with screws.

(1-3/4")

NOTE:

If the control unit is installed in a closed rack or multiunit rack assembly, the temperature around the unit may become high when operating. Install the control unit in an environment whose temperature will not rise beyond the maximum permissible ambient temperature of the control unit.

450 mm (17-3/4")

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65 mm (2-9/16")

 

 

 

65 mm (2-9/16")

 

 

 

 

NOTE:

When mounting on a wall, mount the terminal side down.

9

Image 9
Contents Installation Manual About this Manual ContentsNegligence could result in death or serious injury PrecautionsSystem Configurations System configuration examples Standard IP systemIP IP IP Connections System connection diagramIP IP Used How to connect or disconnect stranded wiresUnit Details AccessoriesControl unit common information MountingPart names SpecificationsCentral control unit IS-CCU BNC ConnectionsAdd-on control unit IS-SCU Refer to Output specifications →P.11 Room sub control unit IS-RCU Room sub control unit IS-RCUSet to this position when this unit is connected to IS-IPC IP control unit IS-IPC LAN Mounting When mounting on a wall Back wiringSurface wiring When mounting on a desktop stand Option wires to the unitConnect the CAT5e/6 cable Zoom picture Mounting locations IS-DV and IS-DVFOption wires to the unit with Install the back box in the wall,Fasten the unit to Mounting surface Insert the transparent name plate. IS-DV and IS-DVFClose it until it clicks Connections IS-DV and IS-DVFConnections IS-SS Room sub station IS-RS Connect the CAT5e/6 cable and option wires to the unitC1 C30 Connect the power wires Power supply unit IS-PU-UL and IS-PU-SAC cord requirements Plug in the AC cord securelyTechnical Data and Precautions Technical dataTechnical precautions FCC Warranty

834168 C P0811JZ specifications

The Aiphone 834168 C P0811JZ is a cutting-edge intercom solution designed to enhance communication and security in a variety of settings. This model is particularly suitable for residential, commercial, and industrial applications, thanks to its robust features and advanced technologies.

One of the main characteristics of the Aiphone 834168 C P0811JZ is its user-friendly interface. The system includes a high-resolution display that provides clear visuals for monitoring and communication. The keypad is intuitive, allowing users to easily navigate the functions and access various settings without the need for extensive training.

This model employs advanced digital communication technologies, ensuring high-quality audio transmission. The integrated noise-cancellation feature minimizes background noise, allowing for clearer conversations even in noisy environments. Additionally, the unit supports full-duplex communication, enabling both parties to speak and listen simultaneously, mirroring a natural conversation.

In terms of video capabilities, the Aiphone 834168 C P0811JZ is equipped with a high-definition camera that offers wide-angle views, making it ideal for monitoring entry points and common areas. The night vision functionality enhances security by allowing visibility in low-light conditions, ensuring users can see who is at their door regardless of the time of day.

Another significant feature of this intercom system is its integration capabilities. The Aiphone 834168 C P0811JZ seamlessly connects with various home automation systems, allowing users to control lighting, locks, and other devices directly from the intercom. This integration enhances overall security and convenience, enabling users to manage their environments with ease.

The system also incorporates advanced security features, including encrypted communication protocols that protect against unauthorized access. This ensures that all conversations remain private, providing peace of mind for users concerned about security vulnerabilities.

Durability is another hallmark of the Aiphone 834168 C P0811JZ. Designed for long-term use, the unit is constructed with high-quality materials that withstand the rigors of daily use. This makes it an excellent investment for any setting looking to enhance its communication and security measures.

In conclusion, the Aiphone 834168 C P0811JZ is an exceptional intercom solution that combines usability, advanced technology, and robust security features. Its impressive capabilities make it a valuable option for anyone looking to improve their communication systems, ensuring safety and convenience in any environment.