Aiphone RY-18L Wiring Diagrams JF Open Voice Color Video System, Electric Strike Wiring Method

Page 2

WIRING DIAGRAMS:

JF OPEN VOICE COLOR VIDEO SYSTEM:

 

 

 

JF-1MD/

JF-DA

 

 

JF-2MED

A1

 

 

A1

JF-DV

 

 

JF-DVF

A2

 

 

A2

 

 

 

 

B1

 

 

 

 

B2

 

 

 

 

S

 

ELECTRIC STRIKE

 

 

S

 

 

 

 

 

WIRING METHOD:

PS-1820UL

DC 18V

NOTE:

Release contacts on the JF-2MED are from

4-pin connector included with unit. Connect Red & Brown wires as shown. Orange & Yellow wires are not used.

Release contacts on the JF-1MD are L/L terminals.

 

 

+

+

 

 

 

 

LOCK

 

-

-

 

Add

JF-1MD/

 

POWER

.

 

 

 

jumper

 

 

 

 

 

 

 

 

 

 

 

 

wire from

JF-2MED

 

+ -

 

Gry

RELEASE

BRN to +

A1

 

 

(L)BRN

 

 

 

 

 

Red

 

 

 

 

Brn

(L)RED

 

 

A2

 

 

Org

COM

 

 

 

 

 

 

N/O

 

 

 

B1

 

 

Yel

 

 

 

 

 

N/C

 

 

 

B2

 

Use Normally Open

 

 

 

 

 

S

 

contact for electric strike

 

 

 

 

 

 

 

 

 

 

 

S

 

 

 

 

 

 

 

 

 

 

MAGNETIC LOCK

 

PS-1820UL

DC 18V

 

 

 

WIRING METHOD:

 

+

+

Add

 

 

LOCK

 

-

-

 

 

 

.

 

jumper

 

 

 

 

 

 

 

 

 

POWER

 

 

 

wire from

 

 

 

 

 

 

 

 

 

+

-

 

Gry

RELEASE

BRN to +

 

 

 

(L)BRN

 

 

 

 

 

Brn

Red

(L)RED

 

 

 

 

 

COM

 

 

 

 

 

 

Org

 

 

Use Normally Closed

 

 

N/O

 

 

 

 

Yel

 

 

contact for magnetic lock

 

 

N/C

 

 

SPECIFICATIONS:

 

NOTE:

Power Source:

Supplied by master station

Only wiring pertaining to connection of door

Mounting:

No mounting required

release relay is shown here.

For complete system information, please

Terminations:

Color-coded prewired pigtails

consult the main system installation manual.

Relay Input:

12-18V DC, Red, Gray wires, 22AWG

 

Relay Output:

Brown, Red, Orange wires, 18AWG

 

N/O Output rating:

5A at 30V DC

 

 

10A at 125V AC

 

 

3A at 250V AC

 

N/C Ouptut rating:

3A at 30V DC or 125V AC

 

Wiring:

2 conductors from monitor's door release contacts to RY-18L.

 

 

2 conductors from RY-18L to strike, with power for strike wired in series.

Dimensions (HxWxD):

1-3/4" x 7/8" x 7/16", with wires extending approx. 7-1/2"

 

Aiphone Communication Systems

 

1700 130th Ave. N.E.

TOLL FREE TECHNICAL SUPPORT: (800) 692-0200

 

Bellevue, WA 98005

 

(425) 455-0510

TOLL FREE FAX LINE: (800) 832-3765

RY-18L Instr.

FAX (425) 455-0071

E-MAIL: tech-serv@aiphone.com

0307JD

Image 2
Contents Instructions Wiring DiagramsInstallation MK-SERIES Black & White Video SystemSpecifications Wiring Diagrams JF Open Voice Color Video SystemElectric Strike Wiring Method Magnetic Lock