Cooper Lighting FMSLP dimensions S C R I P T I O Nd I M E N S I O N S, FMS12, W P R O F I L E

Page 1

CONFINEMENT

FAIL-SAFE®

 

D E S C R I P T I O ND I M E N S I O N S

The Fail-Safe Low Profile FMSLP Series

 

combines maximum security construction

3" [76mm]

features with energy saving technology. This low

 

profile surface mounted luminaire utilizes a one

12" [305mm]

piece housing, security lensing and tamper

 

resistant fasteners to maximize impact resistance

 

and prevent unauthorized fixture penetration. An

3"

emergency battery pack is available as an option.

[76mm]

U.L. listed and C.S.A. certified for wet locations.

24" [610mm]

M O U N T I N G D I M E N S I O N S

 

FMSLP FMS12CR FMS24CR

1 3 W - 2 1 6 W

F l u o r e s c e n t

FMS12

 

(6) 9/16" x 1"

 

 

 

 

[14 x 25mm] Mtg. Holes

 

 

(4) 9/16" x 1"

 

 

2 1/4" [57mm]

 

[14 x 25mm] Mtg. Holes

 

 

 

Dia. Access Hole

 

 

 

2 1/4" [57mm]

 

 

Dia. Access Hole

8"

12"

 

 

8"

12"

[203mm]

[305mm]

 

 

[203mm] [305mm]

 

 

 

8 3/4"

8 3/4"

 

8"

[222mm] [222mm]

 

25 3/16"

 

[203mm]

 

 

[640mm]

 

(8) 9/16" x 1"

[14 x 25mm] Mtg. Holes 2 1/4" [57mm] Dia. Access Hole

8" 12" [203mm] [305mm]

13 3/8" 13 3/8" 13 3/8" [340mm] [340mm] [340mm]

49 3/16"

[1249mm]

L O W P R O F I L E

13 3/16"

 

 

 

 

 

 

 

 

 

 

 

(6) 9/16" x 1" [14 x 25mm]

 

 

[335mm]

(8) 9/16" x 1" [14 x 25mm]

 

 

 

 

 

FMS24

Mtg. Holes

 

2 1/4" [57mm]

 

Mtg. Holes

 

2 1/4" [57mm]

 

 

Dia. Access Hole

 

 

 

Dia. Access Hole

 

 

 

M A X I M U M S E C U R I T Y R E C E S S E D L U M I N A I R E T 5 L A M P T E C H N O L O G Y T 8 L A M P T E C H N O L O G Y

• Lens choice of prismatic

acrylic, prismatic poly-

13 3/8"

 

13 3/8"

13 3/8"

[340mm]

 

[340mm]

[340mm]

20"

[508mm]

24"

[610mm]

8 3/4"

[222mm]

20"

[508mm]

24"

[610mm]

carbonate or prismatic

tempered glass on fixture

side, clear polycarbonate

O R D E R I N G I N F O R M AT I O N

49 3/16"

[1249mm]

25 3/16"

[640mm]

or clear tempered glass on

environmental side

S A M P L E N U M B E R : F M S L P - X 1 2 - 2 3 2 - 2 7 7 - 8 0 / 8 6 - E B 8 1 - S S N

• Stainless steel tamper-

 

resistant TORX® screws

 

with center pin reject are

 

standard. Allen-head

 

screws with center pin

 

reject are optional

Die-formed 12 ga.-18 ga.

 

CRS body with continuous

 

welded and ground ends.

 

Standard white high

 

reflectance polyester

 

powder coat finish

Lamps by others

• Lens secured by thru-studs

 

and vertically adjustable

 

internal CRS hold-downs

Continuous, concealed

 

piano hinge

One-piece, CRS door frame

 

with die-formed edges and

 

tightly closed corners

 

(gauge to match housing)

• Standard, Class P, CBM/ETL

 

ballast

• U.L. listed, C.S.A. certified,

 

standard wet label

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Product Family

 

 

 

 

 

 

 

Voltage

 

 

 

 

 

 

 

120=120V

 

FMSLP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

277=277V

 

FMS12CR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

347=347V

 

FMS24CR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNV=120V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

through

 

Housing

 

 

 

 

 

 

 

 

 

 

 

277V

 

S=12 ga.

 

 

 

 

 

 

 

 

 

(Ultimax)

 

 

 

 

 

 

 

 

 

X=14 ga.

 

 

 

 

 

 

 

 

 

(Maximum)

 

 

 

 

 

 

 

 

 

D=16 ga. (Medium)

 

 

 

 

 

 

 

 

 

N=18 ga.

 

 

 

 

 

 

 

 

 

(Minimum)

 

 

 

 

 

 

 

 

 

Leave Blank for CR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fixture Width

 

 

 

 

 

 

 

12=12”

 

 

 

 

 

 

 

24=24”

 

 

 

 

 

 

 

Leave Blank for CR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lamp Type

Biaxial Fluorescents

 

1' Nom. Length

140BX=(1) 40W Lamp

 

Compact Fluorescent 2

240BX=(2) 40W Lamps

 

340BX= (3) 40W Lamps

 

113=(1) 13W Quad

 

T8 U Lamps

 

213=(2) 13W Quad

 

126=(1) 26W Quad

1U6T8=32W Lamp

 

226=(2) 26W Quad

1 U 1 5/8=31W Lamp

 

2' Nom. Length

2U6T8=32W Lamp

 

T5 Fluorescents

2U 1 5/8=31W Lamp

 

3U 1 5/8=31W Lamp

 

114=(1) 14W Lamp

 

214=(2) 14W Lamps

4' Nom. Length

 

414=(4) 14W Lamps

T5 Fluorescents

 

124=(1) 24W HO Lamp

128=(1) 28W Lamp

 

224=(2) 24W HO Lamps

228=(2) 28W Lamps

 

324=(3) 24W HO

428=(4) 28W Lamps

 

Lamps2

154=(1) 54W HO Lamp

 

424=(4) 24W HO Lamps

254=(2) 54W HO Lamps

 

454=(4) 54W HO Lamps

 

T8 Fluorescents

 

T8 Fluorescents

 

117=(1) 17W Lamp

 

132=(1) 32W Lamp

 

217=(2) 17W Lamps

 

232=(2) 32W Lamps

 

417=(4) 17W Lamps

 

 

 

 

 

 

 

 

432=(4) 32W Lamps

Lens Type

/

 

 

 

Inner Layer

Environmental Side

 

(optional)

 

84=.125 Clear

 

90=.005 UV

 

Polycarbonate

 

 

Absorbing

 

85=.187 Clear

 

 

Overlay

 

Polycarbonate

 

Fixture Side

 

86=.250 Clear

 

80=.125 Prismatic

 

Polycarbonate

 

 

Acrylic

 

87=.375 Clear

 

81=.156 Prismatic

 

Polycarbonate

 

 

Polycarbonate

 

88=.500 Clear

 

82=.187 Prismatic

 

Polycarbonate 7

 

 

Polycarbonate

 

94=.187 Clear

 

93=.156 Prismatic

 

Tempered Glass

 

 

Tempered Glass

96=.250 Clear

 

 

 

 

Tempered Glass

 

 

 

 

97=.375 Clear

 

 

 

 

Tempered Glass

 

 

 

 

98=.500 Clear

 

 

 

 

Tempered Glass 7

 

 

 

 

 

 

 

 

Ballast

 

EBX2=(2) Ballasts

 

 

Blank=Magnetic

 

for use with

 

 

Ballast

 

Biaxial Lamps

 

 

(Standard)3, 7

EB51=(1) Ballast for

 

 

LEOC8=T8 Energy

use with T5

 

 

Saving

 

lamp

 

 

Ballast 7

 

EB52=(2) Ballasts for

 

 

LE3=Energy Saving

use with T5

 

 

Ballast 8

 

lamps

 

 

 

 

EBT1=(1) Ballast for

 

 

Electronic Ballast1

use with

 

 

EB81=(1) Ballast for

Compact

 

 

use with T8

Fluorescent

 

 

lamp

 

Lamp

 

 

 

 

EBT2=(2) Ballasts for

 

 

EB82=(2) Ballasts for

use with

 

 

use with T8

Compact

 

 

lamps

 

Fluorescent

 

 

EBX1=(1) Ballast for

Lamps

 

 

use with

 

 

 

 

 

Biaxial Lamp

 

 

 

Options

EBP=Emergency Battery Pack

FNL=Fluorescent Night Light 7

GLR=Fuse and Holder

RIF=Radio Interference Filter

(for FMSLP24 only)

Auto Control Modules

ACM/FNL=for FNL 7

On/Off Switches

SPS=Security Push Button 7 TCS=Touch Control System 2, 4, 7

Stainless Steel Door

SSN=Natural Brushed Finish 7

SSP=Polyester Powder Coat

Finish 7

Fasteners

SF1=TORX®-Head (center pin reject) 8

SF3=Allen-Head (center pin reject) 7

Accessories (Order Separately)

9306=Allen-Head Wrench 7

MF12-2FT=Plaster Frame and

Yoke Assembly 5

MF12-4FT=Plaster Frame and

Yoke Assembly 5

MF24-2FT=Plaster Frame and

Yoke Assembly 6

MF24-4FT=Plaster Frame and

Yoke Assembly 6

VRSD=TORX®-Head Vandal

Resistant Screwdriver

1460 COOPER LIGHTING

Notes: For additional options, consult your Cooper Lighting Representative. Specifications and Dimensions subject to change without notice. Electronic ballast may cause interference with other electronic devices. If interference occurs, move the device away from the product or plug/connect into a different circuit/outlet.

1For specific electronic ballast, specify brand and catalog number. 2 Requires Deep Housing=5". 3 For use with Compact Fluorescent, Biaxial, and 20W T12 lamps. 4 For additional information about the TCS option see pages 1106 and 1107. 5 12” width only. 6 24” width only. 7 Available on FMSLP fixtures only. 8 Available on FMS12CR and FMS24CR fixtures only.

Image 1
Contents U N T I N G D I M E N S I O N S S C R I P T I O ND I M E N S I O N SFMS12 W P R O F I L E

FMS24CR, FMSLP, FMS12CR specifications

Cooper Lighting is a prominent name in the lighting industry, known for its innovative and energy-efficient lighting solutions. Among its impressive lineup are the FMS24CR, FMS12CR, and FMSLP models. These fixtures represent the pinnacle of modern lighting technology, offering a blend of performance, versatility, and efficiency that meets the demands of various applications.

The FMS24CR and FMS12CR are robust floodlight models designed for outdoor use, ideal for illuminating large areas such as sports fields, parking lots, and commercial spaces. The FMS24CR boasts a powerful output of 24,000 lumens, while the FMS12CR offers a slightly lower output at 12,000 lumens. Both models are engineered with advanced LED technology, ensuring exceptional energy efficiency and a long operational lifespan. This means significant savings on energy bills and reduced maintenance costs over time.

One of the standout technologies integrated into these fixtures is the lens design, which enhances light distribution and minimizes glare. This ensures that light is evenly dispersed across the designated area, promoting safety and visibility without causing discomfort to the eyes. Moreover, the FMS24CR and FMS12CR come equipped with multiple mounting options, allowing for easy installation and versatility in various environments.

On the other hand, the FMSLP model is designed for low-profile applications where space is at a premium. Despite its compact size, the FMSLP does not compromise on performance. It incorporates similar LED technology to that of its larger counterparts, offering a luminous output that makes it suitable for both indoor and outdoor lighting needs. The slim design of the FMSLP is particularly advantageous for applications requiring discreet yet effective lighting, such as walkways and entrances.

All three models use durable materials, ensuring resilience against outdoor elements such as rain, snow, and UV radiation. They are tested for durability and come with an IP65 rating for dust and moisture protection. This rugged construction makes the FMS24CR, FMS12CR, and FMSLP reliable choices for a variety of commercial, industrial, and residential applications.

In conclusion, Cooper Lighting's FMS24CR, FMS12CR, and FMSLP models offer a comprehensive lighting solution characterized by advanced LED technology, energy efficiency, and versatile application features. Whether for expansive outdoor spaces or confined areas needing discreet lighting, these models provide dependable performance that meets the evolving needs of modern infrastructure.