Cooper Lighting specifications FMR12-X-240, Photometrics, Ordering Information

Page 2

FMR12

PHOTOMETRICS

Candlepower Distribution

 

 

 

 

 

 

Candlepower

 

 

 

Zonal Lumen Summary

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zone

 

Lumens

%Lamp

 

%Luminaire

 

 

 

 

 

Test No. 5919

 

Deg.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1495

 

1495

 

 

0-30

 

1120

17.5

 

35.7

 

 

 

 

 

 

FMR12-X-240

 

 

 

 

 

 

 

 

 

 

 

5

1459

 

1473

 

 

0-40

 

1823

28.5

 

58.1

 

 

 

 

 

300

Lamp=(2) F40T12RS/

 

 

 

 

 

 

 

 

 

 

15

1386

 

1458

 

 

0-60

 

2779

43.4

 

88.5

 

 

 

 

 

 

 

 

 

 

 

WW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25

1221

 

1303

 

 

0-90

 

3140

49.1

 

100.0

 

 

 

 

 

 

Lumens=3200

 

 

 

 

 

 

 

 

 

600

 

35

1131

 

1111

 

 

90-180

0

0.0

 

0.0

 

 

 

 

 

Spacing Criteria

 

 

 

 

 

 

 

 

 

 

45

779

 

720

 

 

0-180

 

3140

49.1

 

100.0

 

 

 

 

 

 

 

 

=1.2

=1.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

55

417

 

388

 

 

 

 

 

 

 

 

 

 

 

 

 

900

Efficiency=49.1%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

230

 

238

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1200

 

 

 

 

 

 

 

 

 

 

 

75

136

 

142

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85

37

 

36

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90

0

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

1500

 

 

 

 

 

 

 

 

Coefficient of Utilization

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

rc

 

 

 

80%

 

 

 

70%

 

50%

 

30%

 

 

10%

0%

 

 

 

 

 

 

 

 

 

rw

70

50

 

 

30

10

 

50

30

10

50

10

50

 

10

50

10

0

 

 

 

 

 

 

 

 

 

RCR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

58

58

 

 

58

58

 

57

57

57

55

55

52

 

52

50

50

49

 

 

 

 

 

 

 

1

 

54

53

 

 

51

49

 

51

50

48

49

47

48

 

46

46

44

43

 

 

 

 

 

 

 

2

 

51

47

 

 

45

42

 

46

44

42

45

41

43

 

40

42

39

38

 

 

 

 

 

 

 

3

 

47

43

 

 

39

37

 

42

39

36

41

36

39

 

35

38

35

34

 

 

 

 

 

 

 

4

 

44

39

 

 

35

32

 

38

34

32

37

31

36

 

31

35

31

30

 

 

 

 

 

 

 

5

 

40

35

 

 

31

28

 

34

31

28

33

28

32

 

27

31

27

26

 

 

 

 

 

 

 

6

 

37

31

 

 

26

25

 

31

27

25

30

24

29

 

24

29

24

23

 

 

 

 

 

 

 

7

 

35

29

 

 

25

22

 

28

24

22

27

22

27

 

22

26

21

21

 

 

 

 

 

 

 

8

 

32

26

 

 

22

19

 

25

22

19

25

19

24

 

19

24

19

18

 

 

 

 

 

 

 

9

 

29

23

 

 

19

17

 

23

19

17

22

17

22

 

17

21

17

16

 

 

 

 

 

 

10

27

21

 

 

17

15

 

21

17

15

20

15

20

 

15

20

15

14

rc=Ceiling reflectance, rw=W all reflectance, RCR=Room cavity ratio CU Data Based on 20% Effective Floor Cavity Reflectance.

ORDERING INFORMATION

SAMPLE NUMBER: FMR-D12-340-120-80/86-LE3-GLR

LNL= LED Night Light (50,000 hrs.) provided by Cooper

Specifications and Dimensions subject to change without notice.

ADC041628

Fail-Safe • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801

03/29/2007 8:41:36 AM

Image 2
Contents Lens HousingMounting Yoke Assembly FastenersOrdering Information FMR12-X-240Photometrics